• 제목/요약/키워드: elimination method

검색결과 980건 처리시간 0.025초

A New Switching Pattern for Multilevel Inverter Based on Selective Harmonic Elimination Using Genetic Algorithm

  • Fekari, Seyyed Amir;Iranaq, Ali Reza Marami;Sabahi, Mehran
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권3호
    • /
    • pp.305-311
    • /
    • 2014
  • In this paper, a new switching pattern is presented for multilevel inverters. With changing off-angel of each switch, the on time interval of all switches will approximately be equal and then the lifetime of inverter will increase, also using this method can reduce electrical stress on switches in higher levels of inverter. Switching angels as for desired modulation index are calculated using genetic algorithm whereas selective harmonics are controlled within the allowable range. The computed angels are simulated in Matlab/Simulink for respective circuits to validate the results.

Thiobacillus ferrooxidans 생물막과 화학적 방법에 의한 항화수소 처리 공정 개발

  • 정승호;장영선;차진명;김태원;이광연;오민하;박돈희
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2002년도 생물공학의 동향 (X)
    • /
    • pp.423-426
    • /
    • 2002
  • A novel process for $H_2S$ gas treatment has been introduced, based on the combined action of a chemical absorption step and a biological step involving the biocatalytic activity of the bacterium Thiobacillus ferrooxidans. The aim of this study is the development of a process for $H_2S$ elimination from gas streams based on that chemical/biological method. The immobilized biomass reactor/chemical adsorption system is suitable for application of the removal of $H_2S$. A double stage reactor was used for the experimental work. The removal efficiencies of over 99% were observed in the range of inlet $H_2S$ concentration from 200 to 1,000ppm. The novel process showed the stable elimination efficiencies of over 95% under the retention time range from 20 to 40sec at the 1,000ppm of $H_2S$ inlet concentration.

  • PDF

In vivo Brain-to-blood Efflux Transport of Choline at the Blood-brain Barrier

  • Lee Na-Young;Kang Young-Sook
    • Biomolecules & Therapeutics
    • /
    • 제14권1호
    • /
    • pp.45-49
    • /
    • 2006
  • The purpose of this study was to clarify the efflux transport system of choline from brain to blood across the blood-brain barrier (BBB) in rats using the brain efflux index (BEI) method. $[^3H]$Choline was micro-injected into parietal cortex area 2 (Par2) of the rat brain, and was eliminated from the brain with elimination halflife of 45 min. The BBB efflux clearance of $[^3H]$choline was about 124 mL/min/g brain, which was determined from combination of an elimination rate constant $(1.54X10^{-2}min^{-1})$ and the distribution volume in the brain (8.05 mL/g brain). The efflux of $[^3H]$choline was inhibited by unlabeled choline in a dose-dependent manner and was significantly inhibited by cationic substrates, such as hemicholinium-3 and tetraethylammonium (TEA). These results suggest that the BBB may act as an efflux pump for choline to reduce the excessive choline concentration in the brain interstitial fluid.

3상 전압형 인버어터를 구동하기 위한 SHE PWM의 최적 스위칭 패턴 (Optimal Switching Pattern of SHE PWM for drive Three Phase Voltage Type Inverter)

  • 이윤종;정동화;김혁주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.347-350
    • /
    • 1987
  • This paper is proposed the optimal switching pattern of sleeted harmonic elimination (SHE PWM). It defined harmonic elimination band (HBE) to find the solution of Constant Voltage (CV), and sought all solutions which we are included HEB. Then, it calculated generalised klirr factor (GKF) by this solution and decided optimal switching pattern, used as initial conditions of newton raphson (NR) method to decide switching pattern at variable voltage (W). This strategy is applied to 1HP three phase induction motor. From the result, the validity of theoretical proposition can be verified.

  • PDF

Grid-friendly Control Strategy with Dual Primary-Side Series-Connected Winding Transformers

  • Shang, Jing;Nian, Xiaohong;Chen, Tao;Ma, Zhenyu
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.960-969
    • /
    • 2016
  • High-power three-level voltage-source converters are widely utilized in high-performance AC drive systems. In several ultra-power instances, the harmonics on the grid side should be reduced through multiple rectifications. A combined harmonic elimination method that includes a dual primary-side series-connected winding transformer and selective harmonic elimination pulse-width modulation is proposed to eliminate low-order current harmonics on the primary and secondary sides of transformers. Through an analysis of the harmonic influence caused by dead time and DC magnetic bias, a synthetic compensation control strategy is presented to minimize the grid-side harmonics in the dual primary side series-connected winding transformer application. Both simulation and experimental results demonstrate that the proposed control strategy can significantly reduce the converter input current harmonics and eliminates the DC magnetic bias in the transformer.

Large Solvent and Noise Peak Suppression by Combined SVD-Harr Wavelet Transform

  • Kim, Dae-Sung;Kim, Dai-Gyoung;Lee, Yong-Woo;Won, Ho-Shik
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권7호
    • /
    • pp.971-974
    • /
    • 2003
  • By utilizing singular value decomposition (SVD) and shift averaged Harr wavelet transform (WT) with a set of Daubechies wavelet coefficients (1/2, -1/2), a method that can simultaneously eliminate an unwanted large solvent peak and noise peaks from NMR data has been developed. Noise elimination was accomplished by shift-averaging the time domain NMR data after a large solvent peak was suppressed by SVD. The algorithms took advantage of the WT, giving excellent results for the noise elimination in the Gaussian type NMR spectral lines of NMR data pretreated with SVD, providing superb results in the adjustment of phase and magnitude of the spectrum. SVD and shift averaged Haar wavelet methods were quantitatively evaluated in terms of threshold values and signal to noise (S/N) ratio values.

인삼 extract중의 $\alpha$-pyrrolidone검정 (Determination of $\alpha$--pyrrolidone in panax ginseng Extracts)

  • 서정상
    • 약학회지
    • /
    • 제13권4호
    • /
    • pp.111-120
    • /
    • 1969
  • The determination of $\alpha$-pyrrolidone in ginseng extract by gas liquid chromatography (GLC) was established. $\alpha$-Pyrrolidone in extract was tentatively identified by comparison of the relative retention time of sample peak with those of reference compound and coinjection noted peak enhancement. The .alpha.-pyrrolidone peak elimination was demonstrated by formation of oxime when treated with excess of NH$_{2}$OH ${\cdot}$ HCl and NaOH, allowed to stand at room temperature for 5 minute. The elimination was also observed when samples were treated by the same procedure. The above method was proved to be useful for the determination of $\alpha$-pyrrolidone in ginseng extract and in ginseng extract mixed with 51 plant extracts.

  • PDF

마커 자동 인식 향상 방법에 관한 연구 (The study for improve a method of Marker auto- identification)

  • 이현섭
    • 한국운동역학회지
    • /
    • 제13권1호
    • /
    • pp.23-38
    • /
    • 2003
  • The purpose of this study is to develop an improved marker auto-identification algorithm for reduce of data processing time through improve the efficiency of noise elimination and marker separation. The maker auto-identification algorithm was programming named KUMAS used Delphi language. For the study, various experiments were conducted for the verification of KUMAS. and compared two systems of established with the KUMAS. Four different motions - cycling, gait, rotation, and pendulum -, were selected and tested. Motions were filmed 30Hz frames rate per second. ${\chi}^2$ used for statistical analysis. Significant level were ${\alpha}=.05$. The test results were as follow. 1. Increased the success ratio of marker auto-identification. 2. The efficiency of marker auto-identification was remarkably improved through marker separation, noise elimination. 3. The marker auto-identification ability was improved in 2D-image plane include the 3D motion. 4. Significant different were found between KUMAS and B-SYS(established system) with non-input the artificial noise frames, input the artificial noise frames and total frames.

Reaction Intermediate of Organic Sulfur Compound Ⅰ. Elimination Mechanism of Sulfonyl Chloride

  • Tae-Seop Uhn;Jong-Pal Lee;Hyun-Seok Park;Hyung-Tae Kim;Zoon-Ha Ryu
    • Bulletin of the Korean Chemical Society
    • /
    • 제11권1호
    • /
    • pp.60-64
    • /
    • 1990
  • The reactions of alkanesulfonyl chlorides with pyridines in the presence of various solvents have been studied by means of kinetic method. Alkanesulfonyl chlorides bearing ${\alpha}$-hydrogen with the normal attack of pyridine is found to be at the ${\alpha}$-hydrogen with elimination to form the sulfene intermediate evidently. From the mass spectra by the reaction of ethanesulfonyl chloride with 3-picoline in the presence of methanol-$d_1$, it has shown that the reaction has a witness favorable to the slulfene intermediate.

DM 필터에서의 적분기제거에 관한 연구 (A Study on the Elimination of Integrator in DM Filters)

  • 신재호;이종각
    • 대한전자공학회논문지
    • /
    • 제23권3호
    • /
    • pp.409-414
    • /
    • 1986
  • To eliminate the requirement of multiplications in nonrecursive filter realization, the use of a delta modulation(DM) has been studied by several researchers. However, the structure of DM filters inevitably contains an intergrator that is cascaded with the arithmetic unit to operate convolution summation. In this paper we porpose a method to determine the coefficients that may be used for implementation of a DM filter without an integrator. Also, we obtain the condition by which one can exclude the response errors due to the elimination of the integrator. By computer simulations it is shown that the performance of the proposed filter is very good, providing that the condition is satisfied.

  • PDF