• 제목/요약/키워드: electrostatic hazard

검색결과 12건 처리시간 0.021초

재해분석을 통한 정전기 안전관리 수준 향상 방안 연구 (A Study on the Improvement Plan of Electrostatic Safety Management Level through Injury Analysis)

  • 최상원;정성춘;박재석;양정열;변정환
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.37-45
    • /
    • 2019
  • The characteristic of fire and explosion related to electrostatic discharge is that it is difficult to reproduce the electrostatic charge and discharge phenomenon in addition to the large human and material damage. Therefore, in order to prevent accidents and disasters related to electrostatic in fire and explosion hazard areas, it is important to manage the level of electrostatic in a safe manner from the perspective of system between industrial facilities and human bodies. Rule 325 of the Occupational Safety and Health Regulations, "Prevention of Fire / Explosion due to Electrostatic", requires the use of grounding, conductive materials, humidification and electrification in order to prevent the risk of disaster caused by static explosion and electrostatic in the production process. In order to comply with these measures, related technologies, standards and systems are needed from the viewpoint of preventive measures related to electrostatic in fire and explosion hazard areas, but in Korea, it is still insufficient. Therefore, technical, institutional and managerial measures are needed as a precautionary measure to improve the level of ESD safety in fire and explosion hazard areas and prevent electrostatic related injury. In Korea, we analyzed the current status and characteristics of electrostatic related disaster by using the statistics of industrial accident and fire statistics of the Ministry of Employment and Labor. We also analyzed the current status and characteristics of electrostatic related disasters in Japan using JNIOSH accidents and disasters investigation cases and JNIOSH fire accident data of Japan Fire Bureau. The purpose of this study is to compare and analyze the current status of electrostatic related accidents and disasters in Korea and Japan in order to improve the safety management of electrostatic in fire and explosion hazard areas. In order to prevent accidents and disasters in the industrial field, The technical, institutional, and managerial measures to manage the level of electrostatic in a safe state were derived from the system point of view.

가연성가스에 대한 정전기 대전방지복의 정전기 위험성 평가 (Hazard analysis for electrostatic of Electrostatic removing wear about combustible gas)

  • 정재희;서대원;구자혁;이영철;조병학;박성수;류근창;홍성경;김준호
    • 한국가스학회지
    • /
    • 제4권2호
    • /
    • pp.33-36
    • /
    • 2000
  • 가연성가스의 정전기 대전방지복에 대한 정전기 위험성 평가결과 사용기간에 따라 대전압이 증가하는 경향을 나타내었다. 그러나 대전전하량은 정전기 대전 방지복의 기준치인 0.6$\mu$C 이하였다. 대전압이 증가하는 원인은 일반섬유의 부플음 현상 및 기타 현상 때문으로 판단된다. 또한, 제전 방한복 ('96)의 대전전하량은 0.82$\mu$C로 화재$\cdot$폭발 가능성이 있는 것으로 나타났다. 따라서 이에 대한 개선 및 관리대책이 요구된다.

  • PDF

부유 분진의 정전압에 의한 최소착화에너지 위험성평가 (Hazard Evaluation of Minimum Ignition Energy by Electrostatic Voltage in Suspended Dust Particles)

  • 한우섭
    • Korean Chemical Engineering Research
    • /
    • 제59권3호
    • /
    • pp.359-365
    • /
    • 2021
  • 본 연구에서는 분진의 착화 특성 및 정전기 위험성 평가법을 실험적으로 조사하였다. 착화에너지 시험은 PE(HD), PE(LD), PMMA 분진에 대해 MIKE-3장치를 사용하여 실시하였다. PE (HD)의 경우 약 8 ms의 일정 시간 경과 후에 분진운의 착화 화염이 형성되고, 착화원 중심부에서는 화염 핵이 관찰되지 않았다. 분진의 분산 횟수가 증가함에 따라 정전압이 증가하고 분진 농도에 따른 정전압 발생 증가율은 PMMA, PE(LD), PE (HD) 순으로 가장 높았다. PE(HD) 분진의 분산 조건이 정전압에 미치는 영향을 조사하였으며, 분산 횟수가 많아질수록 정전압이 증가하였고 동일한 분산 횟수에서는 분진 농도가 높아질수록 정전압이 증가하였다. 정전기 착화에 의한 화재폭발사고 예방을 위한 안전 정전압은 PE(HD), PE(LD)-1, PE(LD)-2, PMMA에 있어서 각각 2.58, 44.72, 25.82, 8.16 kV로 추정되었다. 정전압 측정자료를 사용하여 정전기 착화 위험성을 효율적으로 조사하여 최소착화에너지를 추정하는 방법을 제안하였다.

가스충전소에서 작업복의 정전기 안전관리에 관한 연구 (A Study on the Safety Management of the Electrostatic in Working Clothes at the Gas Station)

  • 이금환;정재희
    • 한국안전학회지
    • /
    • 제24권6호
    • /
    • pp.39-44
    • /
    • 2009
  • In order to prevent fire and explosion due to the electrostatic discharge at the Gas Station etc. This result will be applied to standard in the future. Wearing the non-electrostatic removing wear, Charged voltage of human body is 3,980V(MIE is approximately 0.79mJ). There is a possibility of fire explosion because the MIE of LP gas is 0.25mJ. In accordance with using period(whasing times), Charged voltage is shown that propensity is increased. Electrostatic charge amount is upper standard($0.6{\mu}$C) of the hazard of electrostatic removing wear. There is a possibility of fire and explosion. Therefore, countermeasure and management are needed about gas station worker.

유동층 건조설비에 있어서 분진의 정전기 위험성에 관한 실험적 연구 (Experimental Study on Electrostatic Hazards of Powder in Fluidized Bed)

  • 문균태;정재희;최광석
    • 한국안전학회지
    • /
    • 제25권4호
    • /
    • pp.19-24
    • /
    • 2010
  • A large amount of electrostatic charges is often generated on polymer powders in fluidized bed and thereby may lead to electrostatic problems. In this study, to evaluate electrostatic hazards of powder in fluidized bed, the electric field(E[v/m]) and the charge amount(q[c/g]) during fluidizing were monitored. We also investigated the Minimum Ignition Energy(MIE [J]) of sample powder used in fluidized bed with the Hartman vertical-tube apparatus. The batch-type fluidized bed system and 2kg as Polypropylene(PP) resin powders were used in the experiments. The following results were obtained: (1) Even when a safe margin of several times was considered, the values of E obtained with PP powder in this paper did not exceed 3 to 5kV/cm, at which an incendiary electrostatic discharge could occur. (2) the ave. q was -0.26${\mu}$C/g during fluidizing. This value was high enough to cause electrostatic agglomeration and adhesion. (3) the entrained PP powder in upper column due to fluidizing could be ignited by electrostatic discharges of 71mJ.

정전기 방전 평가를 위한 간이형 도구 개발에 관한 연구 (A Study on the Development of Simulating Tool for Evaluation of Electrostatic Discharge)

  • 최상원
    • 한국안전학회지
    • /
    • 제26권3호
    • /
    • pp.15-22
    • /
    • 2011
  • Explosion and fire cause about 30 reported industrial major accidents a year by ignition source which discharge of electrostatic generated to flammable gas, vapor, dust and mixtures. It brings economically and humanly very large loss that accident was caused by fire and explosion from electrostatic discharge. Thus, it is very important that electrostatic discharge energy is to be control below not to be igniting flammable mixtures. There are two kinds of analysis model for electrostatic discharge, human body model and machine model. Human body model is available the parameter of human's electrical equivalent that capacitance is 100 pF, resistance is $1.5k{\Omega}$. To simulate and visualize the electrostatic discharge from human body need a very expensive and high voltage simulator. In this paper, we measured the value of capacitance and resistance concerned with test materials and sizing of specimen and the value of charged voltage concerned with test specimen and distance to develop an electrostatic charge/discharge simulating tool for teaching with which concerned industrial employee and students. The result of experiments, we conformed that the minimum ignition energy of methane-oxygen mixtures meets well the equation $W=1/2CV^2$, and found out that the insulating material and sizing of equivalent value having human body mode are the poly ethylene of 200 mm and 300 mm of diameter. Developed electrostatic charge/discharge simulating tool has many merits; simple mechanism, low cost, no need of electric power and so on.

방폭구조 ESD Detector 개발 및 본질안전 특성 분석에 관한 연구 (A Study on the Development of Explosion Proof ESD Detector and Intrinsic Safety Characteristics Analysis)

  • 변정환;최상원
    • 한국안전학회지
    • /
    • 제35권1호
    • /
    • pp.1-11
    • /
    • 2020
  • Article 325 (Prevention of Fire Explosion due to Electrostatic) of the Rule for Occupational Safety and Health Standard specifies that in order to prevent the risk of disasters caused by static electricity, fire, explosion and static electricity in the production process, However, in order to do this, it is absolutely necessary to use a pre-detection technology and a detector for antistatic discharge prediction, which is a precautionary measure by static electricity in a fire / explosion hazard place, but in Korea, And there is no technical standard for the application of the technology of the explosion proof structure of the related equipment. Research methods include domestic and overseas electrostatic discharge detection technology and literature investigation of related equipment explosion proofing technology, domestic and foreign electrostatic discharge detection device production and use situation investigation, advanced foreign technology data analysis and benchmarking. In particular, we sought to verify the results of empirical experiments using electrostatic discharge detection technology through sample purchase and analysis of related major products, development of optimization technology through prototype production, evaluation, and supplementation, and expert knowledge through expert consultation. The results of this study were developed and fabricated two prototypes of electrostatic discharge detector based on the technology / standard related to electrostatic discharge detection technology in Korea and abroad through development of electrostatic discharge detection technology and development and production of detector. In addition, based on the development of electrostatic discharge detection technology, we developed an intrinsic safety explosion proof ib class explosion proof technology applicable to the process of using and handling flammable gas and flammable liquid vapor and combustible dust. In the case of the over voltage and minimum voltage are supplied to the explosion-proof structure ESD detector, check the state of the circuit and the transient and transient currents generated by the coil and capacitor elements during the input and standby of the signal pulse voltage. Explosion-proof equipment-Part 11: Intrinsically safe explosion proof structure The comparative evaluation with the reference curve in Annex A of "i" confirms that the characteristics of the intrinsically safe explosion protection structure are met.

주유소에서 사용하는 휘발유의 정전기 방전으로 인한 점화위험성에 관한 연구 (A Study on Ignition Hazard Caused by Electrostatic Discharge of Gasoline Used in the Gas Station)

  • 문균태;정재희;미주키 야마구마;최광석
    • 한국안전학회지
    • /
    • 제25권4호
    • /
    • pp.13-18
    • /
    • 2010
  • To investigate electrostatic ignition hazards of commercial gasoline used in the gas station, experiments were conducted dealing with the minimum ignition energy(MIE) of several kinds of gasoline under the various temperature. The conductivity of gasoline that was required for an accurate risk assessment as well as the MIE were also examined. The solvent ignitability apparatus which can heat up the inside of the vessels up to $210^{\circ}C$ was used in this study. Four kinds of premium gasoline and four kinds of regular gasoline, differing with respect to the companies, were used as test specimens. The following results were obtained: (1) all gasoline specimens were so sensitive that even an electrostatic discharge with a very low energy, such as about 0.5mJ, could ignite them. The ignitability of premium gasoline was constant irrespective of the companies. On the other hand, the ignitability of regular gasoline was variable depending on the company. (2) The MIE of all specimens depended markedly on the temperature; in other words, an increase in temperature decreases the ignition energy value. (3) The conductivity values of all specimens were low. Those must be taken into consideration in electrostatic risk assessment.

스마트폰 배터리 보호회로 모듈에 대한 정전기 방전 실험 (Electrostatic Discharge Experiment for Smartphone Battery Protection Circuit Module)

  • 유종경;박경제;전성혁;여준호;조영기;이대헌;김종규
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 추계학술대회
    • /
    • pp.53-54
    • /
    • 2017
  • 본 논문에서는 스마트폰 배터리로 사용되는 리튬 이온 배터리에서 과충전, 과방전, 단락 등으로 인한 폭발 위험성을 막기 위해 사용되는 배터리 보호회로 모듈에 대한 정전기 방전 실험을 연구하였다. 실험 시료로 S사의 리튬이온 배터리를 사용하였고, 정전기 방전 인가를 위해 IEC 61000-4-2 표준에 호환되는 ESD Gun simulator를 사용하였다. 배터리 보호회로 모듈의 여러 핀에 2kV ~ 10kV에서는 2kV 단위로 증가시키고, 10kV ~ 30kV에서는 5kV단위로 증가시켜 접촉방전을 인가하였다.

  • PDF

인화성 액체 도전율에 관한 측정 및 비교(IEC 60079-32-2) 연구 (A Study on the Measurement and Comparison(IEC 60079-32-2) of Flammable Liquid Conductivity)

  • 이동훈;변정환
    • 한국안전학회지
    • /
    • 제34권4호
    • /
    • pp.22-31
    • /
    • 2019
  • The flammable liquid conductivity is an important factor in determining the generation of electrostatic in fire and explosion hazardous areas, so it is necessary to study the physical properties of flammable liquids. In particular, the relevant liquid conductivity in the process of handling flammable liquids in relation to the risk assessment and risk control in fire and explosion hazard areas, such as chemical plants, is classified as a main evaluation item according to the IEC standard, and it is necessary to have flammable liquid conductivity measuring devices and related data are required depending on the handling conditions of the material, such as temperature and mixing ratio for preventing the fire and explosion related to electrostatic. In addition, IEC 60079-32-2 [Explosive Atmospheres-Part 32-2 (Electrostatic hazards-Tests)] refers to the measuring device standard and the conductivity of a single substance. It was concluded that there is no measurement data according to the handling conditions such as mixing ratio of flammable liquid and temperature together with the use and measurement examples. We have developed the measurement reliability by improving the structure, material and measurement method of measuring device by referring to the IEC standard. We have developed a measurement device that is developed and manufactured by itself. The test results of flammable liquid conductivity measurement and the data of the NFPA 77 (Recommended Practice on Static Electricity) Annex B Table B.2 Static Electric Characteristic of Liquids were compared and verified by conducting the conductivity measurement of the flammable liquid handled in the fire and explosion hazardous place by using Measuring / Data Acquisition / Processing / PC Communication. It will contribute to the prevention of static electricity related disaster by taking preliminary measures for fire and explosion prevention by providing technical guidance for static electricity risk assessment and risk control through flammable liquid conductivity measurement experiment. In addition, based on the experimental results, it is possible to create a big data base by constructing electrostatic physical characteristic data of flammable liquids by process and material. Also, it is analyzed that it will contribute to the foundation composition for adding the specific information of conductivity of flammable liquid to the physical and chemical characteristics of MSDS.