• 제목/요약/키워드: electrostatic charge

검색결과 291건 처리시간 0.024초

건조 일체형 드럼세탁기의 건조 조건에 따른 정전기 특성 (Electrostatic Characteristics of the Washer-dryer Combination under Various Drying Conditions)

  • 정승은;박정희;윤창상
    • 한국의류학회지
    • /
    • 제30권5호
    • /
    • pp.753-761
    • /
    • 2006
  • This paper suggests the optimal conditions for the laundry to prevent from the electrostatic charge by the evaluation of the electrostatic characteristics in the full process of washing and drying. Cotton, nylon, and polyester fabrics were used as test washing specimens. Detergent and softener were used under the standard washing cycle, and then the electrostatic characteristics of laundry were measured. The results showed that the moisture regain decreased and the electrostatic charge increased with the drying time. It was observed that the specimen fabrics were already dried up before the standard drying cycle was finished. Consequently, the excessive drying caused a generation of electrostatic charge due to the removal of the trace of moisture remaining and the excessive friction. Especially, the softener played an important role to prevent from a generation of electrostatic charge, whose insertion was more effective in the drying than in the rinsing process. It was also shown that the electrostatic charge could be decreased by drying the fabrics of one kind. On the other hand, for drying the mixed kinds of fabrics, the electrostatic charge increased remarkably. Therefore we suggest that the laundry be classified according to the kinds of fiber, and then be washed and dried before excessive drying to reduce electrostatic charge And further, a proper use of softener is effective to reduce electrostatic charge.

정전기 재해예방을 위한 제전복의 제전특성에 관한 연구 (A Study on the Antistatic characteristics of Antistatic Garments for the Prevention of Static Electricity Hazards)

  • 정재희
    • 한국안전학회지
    • /
    • 제5권1호
    • /
    • pp.57-66
    • /
    • 1990
  • The purpose of this study is to investigate electrostatic charge condition and possibility of electrostatic hazards in case of putting on synthetic smocks and antistatic garments for the purpose of prevention of electrostatic hazards due to a human body electrical charge. It is shown in case of a synthetic smocks, electrostatic voltage by friction is about 2,900 (V), half life period is 12 second, and electrostatic charge is 1.4―1.8 ($\mu$ C). When putting on a synthetic smocks, electrostatic voltage is 2,500―2,800(V). When putting on a jumper of chemical fiber, electrostatic voltage is 8,000(V) . It is, therfore, possible to cause a electrostatic hazards. It is also shown in case of a antistatic garments, electrostatic voltage by friction is 87(V) ―280(V) (washing 90 times), half life period is 3―5 second, and electrostatic charge is 0.24―0.28($\mu$ C) which is much lower than 0.6($\mu$ C) limitation of fire and explosion occurance. When putting on a antistatic garments, electrostatic voltage is 10(V) ―125(V). In conclusion, it is shown when putting on a antistatic garments it is possible to prevent a electrostatic hazards such as fire or explosion due to human body, to prevent a destruction of semiconductor elements and capacity decline, and to prevent a misoperation of automation facilities and semiconductor electric and electronic products.

  • PDF

정전특성(靜電特性)을 이용(利用)한 현미(玄米) 분리기(分離機)의 개발(開發)에 관한 기초(基礎) 연구(硏究) - 벼의 정전특성(靜電特性)에 관하여 - (Development of Brown Rice Separator Using Electrostatic Properties of Rice -Electrostatic Properties of Rice-)

  • 노상하;윤여길;이종환
    • Journal of Biosystems Engineering
    • /
    • 제17권3호
    • /
    • pp.272-284
    • /
    • 1992
  • As a preliminary step toward the development of a multipurpose electrostatic separator for agricultural use, this study investigated the effect of moisture level, geometrical characteristics and the electric field strength of a charging device on the electrostatic charging of brown rice, unhulled paddy, small stones and broken rice that are produced during the milling process. The results are summarized as follows. 1. Average electrostatic charge per unit mass of paddy is greater than that of brown rice. 2. Charge per unit mass of rice kernel increases linearly with moisture content and electric field strength of the charging device, presenting no correlations with length or thickness of rice kernel. 3. Frequency distributions in electrostatic charge per unit mass of paddy and brown rice kernels indicated that the portion, not overlapped, ranged from 10 to 29% with Japonica rice and from 32 to 49% with Indica rice. 4. The difference in moisture content between paddy and brown rice must be over 6%, if they are to be electrostatically separated to over 95%. 5. Theoretical portions of brown rice to be separated from a mixture primarily by the electrostatic charge and secondarily by the length or by the thickness were 95~100% and 27~76%, respectively. 6. Frequency distribution of electrostatic charge for broken kernels overlapped that of paddy and brown rice, which the small stones didn't.

  • PDF

전기집진에서의 난류 입자 이산 (Turbulent Particle Dispersion Effects on Electrostatic Precipitation)

  • 최범석
    • 연구논문집
    • /
    • 통권28호
    • /
    • pp.39-47
    • /
    • 1998
  • Industrial electrostatic precipitation is a very complex process, which involves multiple-way interaction between the electric field, the fluid flow, and the particulate motion. This paper describes a strongly coupled calculation procedure for the rigorous computation of particle dynamics during electrostatic precipitation. The turbulent gas flow and the particle motion under electrostatic forces are calculated by using the commercial computational fluid dynamics (CFD) package FLUENT linked to a finite-volume solver for the electric field and ion charge. Particle charge is determined from both local electrical conditions and the cell residence time which the particle has experienced through its path. Particle charge density and the particle velocity are averaged in a control volume to use Lagrangian information of the particle motion in calculating the gas and electric fields. The turbulent particulate transport and the effects of particulate space charge on the electrical current flow are investigated. The calculated results for poly-dispersed particles are compared with those for mono-dispersed particles, and significant differences are demonstrated.

  • PDF

Formation Mechanism Analysis and Detection of Charged Particles in an Aero-engine Gas Path

  • Wen, Zhenhua;Hou, Junxing;Jiang, ZhiQiang
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제16권2호
    • /
    • pp.247-253
    • /
    • 2015
  • The components of an aero-engine gas path cannot be monitored in a timely way due to a lack of real-time monitoring technologies. As an attempt to address this problem, we have conducted research on a condition monitoring technology based on the charging characteristics of particles in an aero-engine gas path, and emphatically analyze the formation of particles in an aero-engine gas path, the charging mechanism of carbon particles and the factors that influence the charge quantity and polarity. The verification experiments are performed on the simulated experiment platform and a turbo-shaft engine test bench. The results show the carbon particles' carry charge, and an obvious change in the total electrostatic charge level in the aero-engine gas path due to the increased carbon particles produced by burning or abnormal metal particles; the charge number is related to the size of particles, and the bigger carbon particles carry a negative charge and metal particles carry a positive charge; the change in engine power can lead to an obvious change in the level of electrostatic charge in the gas path, and the change in electrostatic charge results from the extra carbon particles formed in the rich-oil burning process. The research provides a reference for establishing the baseline of electrostatic charge while the engine runs on different power. The study also demonstrates the validity of the electrostatic monitoring technology and establishes a base for developing the application of electrostatic monitoring technology in aero-engines.

Comparison of Spray Characteristics between Conventional and Electrostatic Pressure-Swirl Nozzles

  • Laryea, G.N.;No, S.Y.
    • 한국분무공학회지
    • /
    • 제11권1호
    • /
    • pp.24-29
    • /
    • 2006
  • Spray characteristics produced by conventional and electrostatic pressure-swirl nozzles for an oil burner have been studied, using kerosine as a test liquid. The charge injection mechanism is used to design the electrostatic nozzle, where specific charge density, breakup length, spray angle and mean diameter are measured and analyzed. Three nozzles with orifice diameters of 0.256, 0.308 and 0.333mm at injection pressures of 0.7, 0.9, 1.1 and 1.3 MPa are used in the study. In case of the electrostatic nozzle, voltages ranging from -5 to -12kV are applied. Comparison of the spray characteristics is made between the conventional and electrostatic nozzles. The results showed that, the electrostatic nozzle is superior to the conventional nozzle. This is due the effect of voltage on the liquid surface tension.

  • PDF

가스충전소에서 작업복의 정전기 안전관리에 관한 연구 (A Study on the Safety Management of the Electrostatic in Working Clothes at the Gas Station)

  • 이금환;정재희
    • 한국안전학회지
    • /
    • 제24권6호
    • /
    • pp.39-44
    • /
    • 2009
  • In order to prevent fire and explosion due to the electrostatic discharge at the Gas Station etc. This result will be applied to standard in the future. Wearing the non-electrostatic removing wear, Charged voltage of human body is 3,980V(MIE is approximately 0.79mJ). There is a possibility of fire explosion because the MIE of LP gas is 0.25mJ. In accordance with using period(whasing times), Charged voltage is shown that propensity is increased. Electrostatic charge amount is upper standard($0.6{\mu}$C) of the hazard of electrostatic removing wear. There is a possibility of fire and explosion. Therefore, countermeasure and management are needed about gas station worker.

가연성가스에 대한 정전기 대전방지복의 정전기 위험성 평가 (Hazard analysis for electrostatic of Electrostatic removing wear about combustible gas)

  • 정재희;서대원;구자혁;이영철;조병학;박성수;류근창;홍성경;김준호
    • 한국가스학회지
    • /
    • 제4권2호
    • /
    • pp.33-36
    • /
    • 2000
  • 가연성가스의 정전기 대전방지복에 대한 정전기 위험성 평가결과 사용기간에 따라 대전압이 증가하는 경향을 나타내었다. 그러나 대전전하량은 정전기 대전 방지복의 기준치인 0.6$\mu$C 이하였다. 대전압이 증가하는 원인은 일반섬유의 부플음 현상 및 기타 현상 때문으로 판단된다. 또한, 제전 방한복 ('96)의 대전전하량은 0.82$\mu$C로 화재$\cdot$폭발 가능성이 있는 것으로 나타났다. 따라서 이에 대한 개선 및 관리대책이 요구된다.

  • PDF

Modeling Charge Penetration Effects in Water-Water Interactions

  • Choi, Tae Hoon
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권10호
    • /
    • pp.2906-2910
    • /
    • 2014
  • This report introduces Gaussian electrostatic models (GEMs) to account for charge penetration effects in water-water interactions, allowing electrostatic interactions to be accurately described. Three different Gaussian electrostatic models, GEM-3S, GEM-5S, and GEM-6S are designed with s-type Gaussian functions. The coefficients and exponents of the Gaussian functions are optimized using the electrostatic potential (ESP) fitting procedure based on that of the MP2/aug-cc-pVTZ method. The electrostatic energies of ten different water dimers that were calculated with GEM-6S agree well with the results of symmetry-adapted perturbation theory (SAPT), indicating that this designed model can be effectively applied to future water models.

Rompe-Weisel Model에 의한 대전 인체의 정전기 방전 에너지 평가 (Electrostatic Discharge Energy Estimation of the Charged Human Body by the Rompe-Weisel Model)

  • 이종호;김두현;강동규
    • 한국안전학회지
    • /
    • 제18권3호
    • /
    • pp.54-59
    • /
    • 2003
  • The discharge energy by electrostatic discharge of the charged human body is calculated under the assumption that the stored charge is dissipated completely. However, it is well-known that the charge is slightly remained after electrostatic discharge. Therefore, The Rompe-Weisel model of the discharge analysis, which has somewhat more of a physical justification than the conventional energy equation, is proposed. It is proposed that the electrical conductivity of the arc should be proportional to the energy density transferred to it by Ohmic dissipation. For the electrostatic discharge energy analysis, the Rompe-Weisel model was compared by quasi static analysis. As a consequence, a study on a reliable energy evaluation based on simulation models during electrostatic discharge is carried out in this paper and is adopted to estimate the explosion hazards of flammable gases.