• Title/Summary/Keyword: electrospray-mass spectrometry

Search Result 300, Processing Time 0.04 seconds

Quantitative Analysis of Acylcarnitines and Amino Acids Using ESI-MS/MS (ESI-MS/MS를 이용한 아실카르니틴과 아미노산의 정량분석)

  • Kim, Hohyun;Han, Sang-Beom;Yoon, Hye-Ran
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.384-391
    • /
    • 2001
  • In this study, a new quantitative analytical method has been developed for the rapid determination of acylcarnitines and amino acids in human blood using electrospray ionization / tandem mass spectrometry (ESI-MS/MS). Acylarmitines and amino acids were analyzed by tandem mass spectrometry after conversion to their butylesters through treatment with 3N butanolic hydrogen chloride. Acylcrnitines were analyzed using precursor 85 ion scan and alanine, valine, leucine/isoleucine, methionine, phenylalanine, tyrosine, aspartic acid and glutamic acid were analyzed using neutral loss 102 scan, ornitine and citrulline were analyzed neutral loss 119 scan, glycine was analyzed using neutral loss 56 scan, arginine was analyzed using neutral loss 161 scan and argininosuccinic acid was analyzed product ion 459 scan. This method reduced sample preparation time compared to that with conventional amino acid analyzer and liquid chromatography, with high sensitivity and good reproducibility.

  • PDF

Simultaneous analysis of sulfonamides in beef and pork by high performance liquid chromatography and electrospray ionization mass spectrometry (HPLC와 LC/MS에 의한 식육내 잔류 설파제의 동시 분석법)

  • 정봉수;박준조;금모래;김인경;박병옥;한정희
    • Korean Journal of Veterinary Service
    • /
    • v.27 no.1
    • /
    • pp.17-29
    • /
    • 2004
  • A multiresidual analysis was performed to determine 12 sulfonamides(sulfacetamide, sulfadiazine, sulfisomidine, sulfathiazole, sulfapyridine, sulfamerazine, sulfamethazine, sulfamonomethoxine, sulfisoxazole, sulfamethoxazole, sulfaquinoxaline, and sulfadimethoxine) in beef and pork simultaneously. The multiresidual analysis for the sulfonamides currently used was able to analyze 5 kinds of sulfonamides at the same time. The method of this 12 sulfonamides multiresidual analysis in this study was matrix solid-phase dispersion(MSPD) by high performance liquid chromatography (HPLC) and liquid chromatography mass spectrometry (LC/MS). The recovery rate of the materials was measured by MSPD method with 3 different extraction solvents; Dichloromethane, DCM: Ethylacetate(3:1), DCM:EA(9:1). Also, samples (84 beef and 205 pork samples) which were positive by EEC-4 plate test from 2001 to 2003 were tested to investigate the kinds of sulfonamides using HPLC. The results from the study were as follows; 1. The recovery rate of the materials was measured by MSPD method with 3 different extraction solvents; Dichloromethane, DCM:Ethylacetate(3:1), DCM:EA(9:1). The method of extraction solvent with DCM:ethyl acetate(9:1) was the most excellent(87.7∼99.3%) in separation and reappearance. 2. In the LC/MS analysis. of sulfonamides, signal to noise ratio was showed relatively high in the positive mode and special ion in the quality analysis was determined via [M+H]$\^$+/ and m/z 156. A spectrum of sulfonamides was showed from all 12 sulfonamides. 3. The samples positive by the EEC-4 plate, a screening test method, were categorized by sulfonamides through Charm II and confirmed the kinds of sulfonamides through HPLC. 1) Among 84 beef samples positive by EEC-4 plate, 20 samples were positive by Charm II and identified as 7 sulfamethazine, 9 sulfadimethoxine, 1 sulfamonomethoxine and 3 unknown status. 2) Among 205 pork samples positive by EEC-4 plate, 42 samples were positive by Charm II and identified as 19 sulfamethazine, 1 sulfadimethoxine, 4 sulfamonomethoxine and 5 unknown status.

Simple and Sensitive Liquid Chromatography Electrospray Ionization Mass Spectrometry Method for Determination of Glycoalkaloids in Potato (Solanum tuberosum L.)

  • Kim, Jae-Kwang;Bae, Shin-Cheol;Baek, Hyung-Jin;Seo, Hyo-Won;Ryu, Tae-Hun;Kim, Jung-Bong;Won, So-Youn;Sohn, Soo-In;Kim, Dong-Hern;Kim, Sun-Ju;Cho, Myoung-Rae
    • Food Science and Biotechnology
    • /
    • v.18 no.1
    • /
    • pp.113-117
    • /
    • 2009
  • A method was developed using enhanced liquid chromatography coupled with electrospray ionization mass spectrometry for the analysis and quantitation of 2 main potato glycoalkaloids, $\alpha$-chaconine, and $\alpha$-solanine, without any pre-concentration or derivatisation steps. Calibration curves generated by this technique exhibited a linear dynamic range from 0.025 to $50{\mu}g/mL$ and from 0.05 to $50{\mu}g/mL$ for $\alpha$-chaconine and $\alpha$-solanine, respectively. Matrix effects were evaluated by comparing calibration curves measured in matrix-matched and solvent-based systems. Ion suppression due to matrix effects was weak and extraction recoveries of 88 to 114% were obtained in different sample matrices spiked with analyte concentrations ranging from 15 to $35{\mu}g/mL$. Potatoes that had been genetically modified to tolerate glufosinate contained the same glycoalkaloid levels as their non-transgenic counterpart. We suggest complementing compositional comparison assessment strategy by validating quantitative analytical methods for the toxic glycoalkaloids in potato plants.

Determination of Glimepiride in Human Plasma by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry

  • Kim, Ho-Hyun;Chang, Kyu-Young;Lee, Hee-Joo;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.1
    • /
    • pp.109-114
    • /
    • 2004
  • A sensitive method for quantitation of glimepiride in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Glipizide was used as an internal standard. Glimepiride and internal standard in plasma sample was extracted using diethyl etherethyl acetate (1 : 1). A centrifuged upper layer was then evaporated and reconstituted with the mobile phase of acetonitrile-5 mM ammonium acetate (60:40, pH 3.0). The reconstituted samples were injected into a $C_{18}$ reversed-phase column. Using MS/MS in the multiple reaction monitoring (MRM) mode, glimepiride and glipizide were detected without severe interference from human plasma matrix. Glimepiride produced a protonated precursor ion ([M+H]$^+$) at m/z 491 and a corresponding product ion at m/z 352. And the internal standard produced a protonated precursor ion ([M+H]]$^+$) at m/z 446 and a corresponding product ion at m/z 321. Detection of glimepiride in human plasma by the LC-ESI/MS/MS method was accurate and precise with a quantitation limit of 0.1 ng/mL. The validation, reproducibility, stability, and recovery of the method were evaluated. The method has been successfully applied to pharmacokinetic studies of glimepiride in human plasma.

Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

  • Hur, Yeoun;Tae, Sookil;Koh, Yun-Joo;Hong, Sung-Hyun;Yoon, Young Ho;Jang, Haejong;Kim, Sooji;Kim, Kyeong Ho;Kang, Seung Woo;Lee, Youngshin;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • v.5 no.2
    • /
    • pp.42-48
    • /
    • 2014
  • A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI-MS/MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column ($150mm{\times}2.0mm$, $4{\mu}m$) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/v) at a flow rate of $450{\mu}L$/min. Porphyrins and the internal standard (IS), coproporphyrin I-$^{15}N_4$, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.

Determination of a Novel Antiangiogenic Agent KR-31831 in Rat Plasma by Liquid Chromatography-Tandem Mass Spectrometry

  • Kim, Sook-Jin;Lee, Seung-Seok;Ji, Hye-Young;Lee, Hong-Il;Lee, Seon-Kyoung;Yi, Kyu-Yang;Yoo, Seong-Eun;Hwang, Jeong-Sook;Lee, Hye-Suk
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.217.2-217.2
    • /
    • 2003
  • A liquid chromatography-tandem mass spectrometric (LC/MS/MS) method was developed for the determination of a new anti-angiogenic drug KR-31831 in rat plasma. KR-31831 and internal standard, KR-31543 were extracted from rat plasma with dichloromethane at basic pH. A reverse-phase LC separation was performed on Luna C8 column with the mixture of acetonitrile-ammonium formate (10 mM, pH 4.5) (67:33, v/v) as mobile phase. The detection of analytes was performed using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. (omitted)

  • PDF

Mass Spectrometric Determination of Zn2+ Binding/Dissociation Constant for Zinc Finger Peptides

  • Lee, Choong Sik;Park, Soo Jin;Lee, Jae Young;Park, Sungsu;Jo, Kyubong;Oh, Han Bin
    • Mass Spectrometry Letters
    • /
    • v.6 no.1
    • /
    • pp.7-12
    • /
    • 2015
  • In the present study, we proposed a simple ESI-MS model for determining $Zn^{2+}$ binding (or dissociation) constants for zinc finger peptides (ZFPs) with a unique ${\beta}{\beta}{\alpha}$ fold consensus. The ionization efficiency (response) factors for this model, i.e., ${\alpha}$ and ${\beta}$, could be determined for ZiCo ZFP with a known $Zn^{2+}$ binding constant. We could determine the binding constants for other ZFPs assuming those with a ${\beta}{\beta}{\alpha}$ consensus conformation have the same ${\alpha}/{\beta}$ response ratio. In general, the ZPF dissociation constants exhibited $K_d$ values of $10^{-7}{\sim}10^{-9}M$, while $K_d$ values for a negative control non-specific $Zn^{2+}$ peptides were high, e.g., $5.5{\times}10^{-6}M$ and $4.3{\times}10^{-4}M$ for BBA1 and melittin, respectively.

Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of ε-Acetamidocaproic Acid in Rat Plasma

  • Kim, Tae Hyun;Choi, Yong Seok;Choi, Young Hee;Kim, Yoon Gyoon
    • Toxicological Research
    • /
    • v.29 no.3
    • /
    • pp.203-209
    • /
    • 2013
  • A simple and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of ${\varepsilon}$-acetamidocaproic acid (AACA), the primary metabolite of zinc acexamate (ZAC), in rat plasma by using normetanephrine as an internal standard. Sample preparation involved protein precipitation using methanol. Separation was achieved on a Gemini-NX $C_{18}$ column ($150mm{\times}2.0mm$, i.d., 3 ${\mu}m$ particle size) using a mixture of 0.1% formic acid-water : acetonitrile (80 : 20, v/v) as the mobile phase at a flow rate of 200 ${\mu}l/min$. Quantification was performed on a triple quadrupole mass spectrometer employing electrospray ionization and operating in multiple reaction monitoring (MRM) and positive ion mode. The total chromatographic run time was 4.0 min, and the calibration curves of AACA were linear over the concentration range of 20~5000 ng/ml in rat plasma. The coefficient of variation and relative error at four QC levels were ranged from 1.0% to 5.8% and from -8.4% to 6.6%, respectively. The present method was successfully applied for estimating the pharmacokinetic parameters of AACA following intravenous or oral administration of ZAC to rats.

Identification of IY81149 and Its Metabolites in the Rat Plasma Using the On-Line HPLC/ESI Mass Spectrometry

  • Myung, Seung-Woon;Min, Hye-Ki;Jin, Chang-Bae;Kim, Myung-Soo;Lee, Seung-Mok;Chung, Gi-Ju;Park, Seong-Jun;Kim, Dong-Yeon;Cho, Hyun-Woo
    • Archives of Pharmacal Research
    • /
    • v.22 no.2
    • /
    • pp.189-193
    • /
    • 1999
  • Reversed-phase high-performance liquid chromatography/mass spectrometry (HPLC/MS) with an eletcrospray ionization (ESI) interface was applied to the identification of metabolites of IY81149 in the rat plasma. Fragments obtained using collision-induced dissociation (CID) in both positive and negative modes were utilized to elucidate the structure of metabolites. The eluent from the conventional HPLC column was split and directly introduced into an ESI-mass spectrometer for the identification of the structures. the CID technique allowed the sensitive identification of sulfonyl-IY81149 and hydroxy-IY81149 from the rat plasma.

  • PDF