• Title/Summary/Keyword: electrospray tandem mass

Search Result 152, Processing Time 0.026 seconds

IN VIVO METABOLISM OF 2-METHYLAMINOETHYL-4,4'-DIMETHOXY-5,6,5',6'-DIMETHYLENEDIOXYBIPHENYL-2'-CARBOXY-2-CARBOXYLATE (DDB-S) BY LC/ESI TANDEM MASS SPECTROMETRY

  • Son, Jung-Hyun;Lee, Jae-Ick;Yang, Ryung;Kim, Dong-Hyun
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.251.2-251.2
    • /
    • 2002
  • 2-Methylaminoethyl- 4,4' -dimethoxy- 5, 5',6,6' -dimethylenedioxybiphenyl- 2' -carboxy- 2-carboxylate (DDB-S) is a synthetic compound derived from DDB. which is protects liver against carbon tetrachloride-, D-galactosamine-, thioacetamine-, and prednisolone- induced hepatic injury in experimental animals. We assessed the use of liquid chromatography/electrospray iontrap tandem mass spectrometry (LC/MS/MS) method to identify and quantify in vivo metabolites and to measure excretion. (omitted)

  • PDF

Simultaneous Determination of Statins in Human Urine by Dilute-and-Shoot-Liquid Chromatography-Mass Spectrometry

  • Jang, Haejong;Mai, Xuan-Lan;Lee, Gunhee;Ahn, Jae Hyoung;Rhee, Jongsook;Truong, Quoc-Ky;Vinh, Dinh;Hong, Jongki;Kim, Kyeong Ho
    • Mass Spectrometry Letters
    • /
    • v.9 no.4
    • /
    • pp.95-99
    • /
    • 2018
  • An innovative, simple, and rapid assay method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated for the simultaneous determination of eight statin drugs in human urine. A simple sample clean-up procedure using the "dilute and shoot" (DAS) approach enabled a fast and reliable analysis. The influence of the dilution factor was investigated to ensure detectability and reduce the matrix effect. Chromatographic separation was performed on a Phenomenex Kinetex C18 column ($50{\times}3.0mm$ i.d., $2.6{\mu}m$) using an elution gradient of mobile phase A composed of 0.1% acetic acid, and mobile phase B composed of acetonitrile, at a flow rate of 0.35 mL/min. Quantitation was performed on a triple quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode using electrospray ionization in positive ion mode. The total chromatographic run time was 15 min. The method was validated for selectivity, sensitivity, recovery, linearity, accuracy, precision, and stability. The present method was successfully applied to the analysis of Rosuvastatin in urine samples after oral administration to healthy human subjects.

Effects of Column Length and Particle Diameter on Phospholipid Analysis by Nanoflow Liquid Chromatography-Electrospray Ionization-Mass Spectrometry

  • Lee, Ju-Yong;Lim, Sang-Soo;Moon, Myeong-Hee
    • Mass Spectrometry Letters
    • /
    • v.2 no.3
    • /
    • pp.65-68
    • /
    • 2011
  • The effects of column length and particle size on the efficiency of separation and characterization of phospholipids (PLs) are investigated using nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry (nLC-ESI-MS-MS). Since PLs are associated with cell proliferation, apoptosis, and signal transduction, it is of increasing interests in lipidomics to establish reliable analytical methods for the qualitative and quantitative profiling of PLs related to biomarker development in adult diseases. Due to the complexity of PLs, the preliminary separation of PLs is necessary prior to MS analysis. In this study, length of capillary column and the particle size of reversed phase ($C_{18}$) packing materials are varied to find a reliable condition for the high speed and high resolution separation using 8 PL standard mixtures. From experiments, it was found that a capillary column of nLC-ESI-MS-MS analysis for PL mixtures can be minimized to a 5 cm long pulled tip column packed with 3 ${\mu}m$ $C_{18}$ particles without losing resolution.

Development and Validation of an Analytical Method for Glucuronolactone in Energy Drinks by Hydrophilic Interaction Liquid Chromatography-electrospray Tandem Mass Spectrometry

  • Oh, Mi Hyune;Lim, Moo Song;Chai, Jeung Young;Kim, Eun Jung;Cho, Joong Hoon;Lim, Chul Joo;Choi, Sun Ok
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.2
    • /
    • pp.89-95
    • /
    • 2017
  • A rapid, sensitive analytical method for glucuronolactone in beverages was developed and validated using hydrophilic interaction liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HILIC-ESI-MS/MS). To determine the optimum analytical conditions for glucuronolactone, three different kinds of HILIC columns and two mobile phases with different pH values were examined. An amide-bonded stationary phase with a pH 9 acetonitrile-rich mobile phase was the best condition in terms of column retention, ESI-MS/MS response area, and signal-to-noise ratio. After extraction, glucuronolactone was separated through the HILIC amide column and detected by negative ESI-MS/MS in selected reaction monitoring (SRM) mode. Nine energy drinks sold in Korea were spiked with glucuronolactone at a concentration of 5 ng/mL; the Monster $Energy^{TM}$ sample showed the smallest peak area and its signal-to-noise ratio was used for method validation. Good linearity was obtained in the concentration range from 20 to 1500 ng/mL with a correlation coefficient > 0.998. The developed method had a limit of detection (LOD) of 6 ng/mL and a limit of quantitation (LOQ) of 20 ng/mL. The recovery of this method at concentration of 20, 100, 500, and 1000 ng/mL was 96.3%-99.2% with relative standard deviations (RSD) of 1.6%-14.0%. A reproducibility precision assessment at concentration of 100 and 500 ng/mL was carried out among three laboratories. The recovery of that evaluation was 95.1%-102.3% with RSD of 2.7%-7.0%. An analysis of variance indicated that there was no difference between the recovery results of the three laboratories at the 5% significance level. The validated method is applicable to inspecting beverages adulterated with glucuronolactone in Korea.

Pentafluorophenylprophyl Ligand-based Liquid Chromatography-Tandem Mass Spectrometric Method for Rapid and Reproducible Determination of Metformin in Human Plasma

  • Yang, Jeong Soo;Oh, Hyeon Ju;Jung, Jin Ah;Kim, Jung-Ryul;Kim, Tae-Eun;Ko, Jae-Wook;Lee, Soo-Youn;Huh, Wooseong
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3284-3288
    • /
    • 2013
  • This paper describes first development and validation of pentafluorophenylprophyl ligand-based liquid chromatography coupled to tandem mass spectrometry (PFPLC-MS/MS) method to determine metformin, a highly polar compound, in human plasma. Metformin and Phenformin (internal standard) were extracted from human plasma 50 ${\mu}L$ with a single-step protein precipitation. The chromatographic separation was performed using a linear gradient elution of mobile phase involving 5.0 mM ammonium formate solution with 0.1% formic acid (A) and acetonitrile (B) over 3.0 min of run time on a Phenomenex Luna PFP column. The detection was performed using a triple-quadrupole tandem mass spectrometer (Waters Quattro micro) with electrospray ionization in the mode of positive ionization and multiple-reaction monitoring (MRM). The developed method was validated with 5.0 ng/mL of lower limit of quantification (LLOQ). The calibration curve was linear over 5-3000 ng/mL of the concentration range ($R^2$ > 0.99). The specificity, selectivity, carry-over effect, precision, accuracy and stability of the method met the acceptance criteria. The method developed in this study had had rapidness, simplicity and ruggedness. The reliable method was successfully applied to high throughput analysis of real samples for a practical purpose of a pharmacokinetic study.

Investigation of Angiotensin Glycosylation by MALDI-TOF and ESI Tandem Mass Spectrometry

  • Park, Soo-Jin;Park, Deok-Hie;Sul, Soo-Hwan;Oh, Sung-Hwan F.;Park, In-Sook;Chung, Doo-Soo;Kim, Hie-Joon;Kim, Min-Sik;Lee, Sang-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.12
    • /
    • pp.1791-1800
    • /
    • 2004
  • Angiotensin I, a model decapeptide, was glycosylated and partially hydrolyzed with HCl (6 N, 80 $^{\circ}C$, 4 h), aminopeptidase, and carboxypeptidase Y. A single peptide mass map obtained from truncated peptides in the partial acid hydrolysate of angiotensin and its glycosylation product mixture by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry enabled sequencing of angiotensin by a combinatorial procedure. MALDI-TOF and electrospray ionization (ESI) tandem mass spectrometric results indicate that both the N-terminal amino group of aspartic acid and the guanidinium group of the second residue arginine are glycosylated.

Quantitative Analysis of the Seventeen Marker Components in Dangguisu-san Using Ultra-performance Liquid Chromatography Coupled to Electrospray Ionization Tandem Mass Spectrometry (LC-MS/MS를 이용한 당귀수산 추출물 중 17종 성분의 함량분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • YAKHAK HOEJI
    • /
    • v.58 no.3
    • /
    • pp.158-164
    • /
    • 2014
  • Dangguisu-san is a well-known traditional Korean herbal medicine prescription and has been widely used to treat ecchymosis, blood stagnation, and pain resulting from physical shock in Korea. In this study, an ultra-performance liquid chromatography-electrospray ionization-mass spectrometer method was established for the simultaneous determination of the 17 biomarker components in Dangguisu-san. All analytes were separated on an UPLC BEH $C_{18}$ ($100{\times}2.1$ mm, $1.7{\mu}m$) column and maintained at $45^{\circ}C$. The mobile phase consisted of two solvent systems, 0.1% (v/v) formic acid in water (A) and acetonitrile (B) by gradient flow. The injection volume was $2.0{\mu}l$ and the flow rate was 0.3 ml/min with detection at mass spectrometer. Calibration curves of the 17 biomarker components were acquired with $r^2$ values ${\geq}0.9951$. The values of limit of detection and quantification of all analytes were 0.02~6.32 ng/ml and 0.05~18.95 ng/ml, respectively. The amounts of the 17 components in Dangguisu-san sample were $3.17{\sim}13,224.50{\mu}g/g$.

Oligomer Complexes of the (VQIVYK + NNQQNY) and (VQIVYK + LYQLEN) Mixing Solutions

  • Jung, Yeon-Ji;Shin, Min-Ji;Kim, Ho-Tae
    • Mass Spectrometry Letters
    • /
    • v.10 no.1
    • /
    • pp.32-37
    • /
    • 2019
  • The ${\pi}-{\pi}$ interactions of the peptide-dimer and peptide-trimer complexes were investigated in the (VQIVYK + LYQLEN) and (VQIVYK + NNQQNY) mixing solutions. The results showed that tyrosine (Y) residues were critical in the formation of hetero peptide-dimers and -trimers during the early oligomerization process. We used collision-induced dissociation (CID) along with electrospray ionization mass spectroscopy (ESI-MS) to obtain the structural information of the hetero-dimers and -trimers. We chose three amyloidogenic peptides-VQIVYK, NNQQNY, and LYQLEN-from tau protein, yeast prion-like protein Sup35, and insulin chain A, respectively. Hetero-dimer, -trimer, -tetramer, and -pentamer complexes were observed in the mass spectra. The tandem mass spectrum of the hetero-dimer and hetero-trimer showed two different fragmentation patterns (covalent and non-covalent bond dissociation). Y-Y interaction structures were also proposed for the hetero-dimer and -trimer complexes.

Identification And Quantification of Steroidal Saponins in Polygonatum Species by HPLC/ESI/MS

  • Ahn, Mi-Jeong;Kim, Jin-Woong
    • Archives of Pharmacal Research
    • /
    • v.28 no.5
    • /
    • pp.592-597
    • /
    • 2005
  • An HPLC/Esl/MS method has been developed to identify and quantify the spirostanol glycosides in the rhizomes of five Polygonatum species. The relative distribution of two steroidal saponins in each extract was established using the selective ion monitoring (SIM) mode via an electrospray ionization (ESI) source. It was found that there were significant differences in the amount of spirostanol glycosides among the Polygonatum Species. The results showed that this method could be used to identify the steroidal saponins in the extracts and differentiate Polygonatum species with high sensitivity and reproducibility in a short time. Fragmentation patterns of the two reference compounds were also discussed with the electrospray ionization multi-stage tandem mass spectroscopy (ESI-MS$^n$).