• 제목/요약/키워드: electrospray

검색결과 440건 처리시간 0.033초

Determination of Enalapril in Human Plasma by High Performance Liquid Chromatography-Electrospray Ionization Mass Spectrometry

  • Yoon, Kyung-Hwan;Kim, Won;Park, Jong-Sei;Kim, Hie-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권6호
    • /
    • pp.878-880
    • /
    • 2004
  • Revered-phase LC-electrospray ionization mass spectrometry was used to selectively determine enalapril from plasma with minimal sample preparation. Detection limit of the method was 1 ng/mL. Precision (within day and between days) and accuracy of the method at various concentrations were acceptable. The analytical technique was used for pharmacokinetic studies after administration of enalapril to human test subjects.

항균성 천연물질의 도포방법에 따른 에어필터 여재의 항균 특성 비교 (Comparison of Antibacterial Ability of Air Filter Media Treated with a Natural Antibacterial Agent by Three Treatment Methods)

  • 박선영;정재희;황기병;배귀남;김용표;노주원
    • 한국대기환경학회지
    • /
    • 제29권2호
    • /
    • pp.125-134
    • /
    • 2013
  • Various antimicrobial technologies have been developed to inactivate bioaerosols in indoor environments. In this study, air filter media were treated with a natural antibacterial agent of Sophora flavescens in order to inactivate the bacteria collected on the air filter. Three treatment methods were applied to manufacture the test antibacterial air filter media: electrospray, nebulization and dip-coating methods. In case of electrospray and nebulization processes, the size distribution of aerosolized natural antibacterial agent was measured using a scanning mobility particle sizer. Staphylococcus epidermidis bacteria were aerosolized to test inactivation of the filter media treated with a natural antibacterial agent. The pressure drop and the antibacterial efficiency of the filter media increased with increasing the mass loading of natural antibacterial agent in each treatment method. The antibacterial efficiency per loaded antibacterial agent mass by the electrospray method was the highest and the filter treated by the dip-coating method was the lowest among three treatment methods.

Focused Electrospray Deposition for Matrix-assisted Laser Desorption/Ionization Mass Spectrometry

  • Jeong, Kyung-Hwan;Seo, Jong-Cheol;Yoon, Hye-Joo;Shin, Seung-Koo
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권8호
    • /
    • pp.2293-2298
    • /
    • 2010
  • Focused electrospray (FES) deposition method is presented for matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. FES ion optics consists of two cylindrical focusing electrodes capped with a truncated conical electrode through which an electrospray emitter passes along the cylindrical axis. A spray of charged droplets is focused onto a sample well on a MALDI target plate under atmospheric pressure. The shape and size distributions of matrix crystals are visualized by scanning electron microscope and the mass spectra are obtained by time-of-flight mass spectrometry. Angiotensin II, bradykinin, and substance P are used as test samples, while $\alpha$-cyano-4-hydroxycinnamic acid and dihydroxybenzoic acid are employed as matrices. FES of a sample/matrix mixture produces fine crystal grains on a 1-3 mm spot and reproducibly yields the mass spectra with little shot-to-shot and spot-to-spot variations. Although FES greatly stabilizes the signals, the space charge due to matrix ions limits the detection sensitivity of peptides. To avoid the space charge problem, we adopted a dual FES/FES mode, which separately deposits matrix and sample by FES in sequence. The dual FES/FES mode reaches the detection sensitivity of 0.88 amol, enabling ultrasensitive of peptides by homogeneously depositing matrix and sample under atmospheric pressure.

정전분무법을 이용한 직접개미산 연료전지 전극촉매의 효율적인 분산 (Effective Dispersion of Electrode Catalysts for Direct Formic Acid Fuel Cells by Electrospray Method)

  • 권병완;김진수;권용재;한종희
    • 전기화학회지
    • /
    • 제11권4호
    • /
    • pp.262-267
    • /
    • 2008
  • 직접개미산 연료전지의 전극 촉매로 사용되는 귀금속 백금-루테늄 촉매를 정전분무법을 이용하여 효율적으로 분산하여 보았다. 전극에 도포된 촉매 양은 분사 시간에 따라 증가하였으나, 분사시간이 80분을 넘는 경우 촉매 응집으로 인하여 연료전지 성능은 감소하는 경향을 보였다. 상용 핸드스프레이로 전극 촉매를 $3.0\;mg/cm^2$ 분산한 경우 얻은 최대 출력밀도 $74\;mW/cm^2$와 비교하여 정전분무법은 적은 양인 $1.85\;mg/cm^2$의 촉매를 분산하고도 $72\;mW/cm^2$의 최대 출력밀도를 얻을 수 있었다.

Electrospray Tandem Mass를 이용한 혈중 글리퀴돈의 정량법 개발 및 생체이용률시험 (Electrospray Tandem Mass Spectrometry for the Quantification and Bioavailability Test of Gliquidone in Human Plasma)

  • 문철진;이은희;양송현;문해란
    • 약학회지
    • /
    • 제49권3호
    • /
    • pp.212-216
    • /
    • 2005
  • A rapid, sensitive and selective electrospray tandem mass spectrometric (ESI-LC/MS/MS) method for the quantitation of gliquidone in human plasma was developed. A bioavailability study of gliquidone tablet (30 mg gliquidone, Boehringer Ingelheim Korea Co.) was performed using the validated ESI-LC/MS/MS method. The dose of 30 mg of gliquidone (1 tablet) was orally administered to 9 healthy Korean subjects. After administration, blood was taken at 0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 7, 9, 12, 24, and 33 hour. The validation data were as follows; the standard curve was linear ($r^2$=0.999) over the concentration range of $10\~1000 ng/ml$. The coefficient of variation for intra- and inter-day assay were $8.30\~18.86$, and $2.19\~12.92\%$, respectively. The lower limit of quantification for gliquidone was 10 ng/ml. The pharmacokinetic parameters obtained were as follows; $AUC_t$ was 3861.17$\pm$1328.61 ng-hr/ml, $C_{max}$ was 831.02$\pm$227.99 ng/ml, $T_{max}$ was $2.94{\pm}0.77 hr,\;K_e$, was 0.19$\pm$0.06 1/hr, and $t_{l/2}$ was 4.47$\pm$3.52 hr. Based on the validated analytical method and pharmacokinetic parameters, a standard guideline of the bioavailability test of gliquidone dosage forms was prepared successfully and could be used for the bioequivalence test of gliquidone preparation.

전기분사를 이용한 의료용 금속 임플란트의 생분해성 PLGA 고분자 코팅 (Biodegradable PLGA Polymer Coating on Biomedical Metal Implants Using Electrospraying)

  • 조성배;박철호;박귀덕;정동준;한동근
    • 폴리머
    • /
    • 제33권6호
    • /
    • pp.620-624
    • /
    • 2009
  • 의료용 금속 임플란트는 우수한 기계적 강도를 바탕으로 결손된 신체 부위의 보강, 대치, 회복을 위해 임상적으로 사용되고 있지만, 낮은 생체적합성 및 독성 때문에 염증 및 후기 혈전증, 재협착의 문제점을 가지고 있다. 이런 단점을 보안하기 위한 다양한 표면처리 기술 중, 본 연구에서는 금속표면에 생분해성 고분자인 poly (lactic-co-glycolic acid) (PLGA)를 이용하여 전기분사 코팅(electrospray coating) 기술을 검토하였다. 전기분사와 용액 인자들의 기초적인 조사를 바탕으로, 코팅 필름의 표면형상은 방울이 날아가는 거리, 용매의 비등점, 방울의 크기에 밀접한 관련이 있다. 고분자 필름의 두께는 분사량에 선형적으로 비례를 하였다. 이 결과는 전기분사된 고분자 방울이 계속적으로 고분자 필름 위에 적층되는 것을 보여준다. 따라서, 전기분사 코팅기술은 스텐트와 같은 의료용 금속 임플란트에 있어서 표면 형상 조절, 나노/마이크로 두께의 단/다중층의 고분자 필름을 제조하는데 적용될 수 있다.

배가스 내 미세먼지 제거를 위한 고성능 집진 기술에 대한 연구 (A Study on High performance Electrical Precipitation Technology for PM Removal in Exhaust Gas)

  • 김소연;김민성;최상미;정민규;이진욱
    • 플랜트 저널
    • /
    • 제18권1호
    • /
    • pp.50-54
    • /
    • 2022
  • 미세먼지 배출 허용 기준이 강화됨에 따라 화력발전소, 제철소, 산업용 열병합 발전소 등 배가스 배출 시설의 미세먼지 제거를 위해 고효율 집진장치 수요가 급증하고 있다. 본 연구에서는 기존 전기집진기에 정전분무 기술을 도입하여 단점을 보완하고 성능을 향상시키는 연구를 진행 중이다. 정전분무는 매우 미세한 액적을 생성하는 목적으로 주로 사용되어왔지만, 집진을 목적으로 할 때는 그 유량이 10mL/min으로 65 ~ 200배에 달하는 고유량 조건이 필요하다. 고유량의 정전분무는 저유량과는 완전하게 다른 분무 형상이 나타나며 코로나 방전 사진 촬영, 그림자 촬영법 등 다양한 촬영을 통하여 이를 가시화하였다.

  • PDF

정전분무법에 의한 결함없는 ZIF-7 박막의 제조 (Preparation of Crack-free ZIF-7 Thin Films by Electrospray Deposition)

  • ;김진수
    • 멤브레인
    • /
    • 제23권4호
    • /
    • pp.278-282
    • /
    • 2013
  • ZIF 재료는 독특한 기체 분리 특성을 포함한 물리적, 화학적 특성 때문에 큰 관심을 받아왔다. 본 연구에서는 ${\alpha}$-alumina 지지체 위에 결함 없고 연속적인 ZIF-7 막을 형성하는 새롭고 효율적인 방법이 연구되었다. 지지체 위에 시딩(seeding)을 하지 않고 직접 ZIF-7 박막을 합성하는데 정전분무법이 처음으로 적용되었다. 이 방법은 전구체 용액을 직접 정전분무함으로 ${\alpha}$-alumina 지지체에 ZIF-7 박막을 형성할 수 있었다. ZIF-7 박막은 XRD, FE-SEM, 단일 기체 투과 장치 등을 이용해 분석하였다.

정전분무법을 이용한 염료감응형 태양전지의 $TiO_2$ 박막 특성에 관한 연구 (A study on the characteristics of $TiO_2$ electrode in dye-sensitized solar cells using electrospray method)

  • 장진주;홍지태;이동길;이경준;손민규;김진경;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1423_1424
    • /
    • 2009
  • Dye sensitized solar cells(DSC) have been very economical and easy method to convert solar energy to electricity. DSC can reach low costs in future outdoor power applications. However, to commercialize the DSC, there are still many shortages to overcome such as a low efficiency in a large size DSC. In this study, DSCs were fabricated by an electrospray coating method for the $TiO_2$ thin film. They were compared with DSCs prepared by conventional coating methods. We conducted an experiment to obtain the optimized parameters of voltage, flow rate, incident angle and distance in the electrospray method. After we manufactured $TiO_2$ film using that way, we could analyze the characteristics of DSC through SEM, UV curve, EIS.

  • PDF