• Title/Summary/Keyword: electropolymerization

Search Result 54, Processing Time 0.02 seconds

Deposition of Alkali Metal Ions at Polypyrrole Film Electrodes Modified with Fullerene (플러렌으로 수식된 피를 고분자 피막전극에 알카리 금속이온의 포집)

  • Cha Seong-Keuck;Lee Sangchun
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.1
    • /
    • pp.16-20
    • /
    • 2004
  • To electropolymerize Polypyrrole(ppy) film modified with fullerene $ions(full^-)$ the cell, Au/5 mM pyrrole, 1mM fullerene, 0.1M $TBABF_4,\;CH_2Cl_2/Pt$, was employed to Prepare the wafer-like type of $electrode/ppy(full^-)ppy(full^-){\ldots}$ electrodes. They were applied to deposit alkali metal ions with the cell of Au(quartz crystal analyzer; QCA)/ppy$(full^-)$, 0.01M metal ion(aq.)/Pt. The depositing rate constant of each ion for $Li^+,\;Na^+,\;K^+,\;Rb^+\;and\;Cs^+$, determined from the first order equation was $1.60\times10^{-8},\;3.13\times10^{-11},\;1.38\times10^{-9},\;2.71\times10^{-11}\;and\;2.98\times10^{-12}mo1.s^{-1}$ respectively. The calculated stoichiometry of the ions determined by quartz crystal microbalance(QCM) at the electrodes was $Li_7C_{60},\;Na_4C_{60},\;K_3C_{60},\;Rb_1C_{60}\;and\;Cs_1C_{60}$ respectively.

Pathogen-Imprinted Polymer Film Integrated probe/Ti3C2Tx MXenes Electrochemical Sensor for Highly Sensitive Determination of Listeria Monocytogenes

  • Xiaohua, Jiang;Zhiwen, Lv;Wenjie, Ding;Ying, Zhang;Feng, Lin
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.431-437
    • /
    • 2022
  • As one of the most hazardous and deadliest pathogens, Listeria monocytogenes (LM) posed various serious diseases to the human being, thus designing effective strategy for its detection is of great significance. In this work, by preparing Ti3C2Tx MXenes nanoribbon (Ti3C2TxR) as carrier and selecting thionine (Th) acted simultaneously as signal probe and functional monomer, a LM pathogen-imprinted polymers (PIP) integrated probe electrochemical sensor was design to monitor LM for the first time, that was carried out through the electropolymerization of Th on the Ti3C2TxR/GCE surface in the existence of LM. Upon eluting the templates from the LM imprinted cavities, the fabricated PIP/Ti3C2TxR/GCE sensor can rebound LM cells effectively. By recording the peak current of Th as the response signal, it can be weakened when LM cell was re-bound to the LM imprinted cavity on PIP/Ti3C2TxR/GCE, and the absolute values of peak current change increase with the increasement of LM concentrations. After optimizing three key parameters, a considerable low analytical limit (2 CFU mL-1) and wide linearity (10-108 CFU mL-1) for LM were achieved. In addition, the experiments demonstrated that the PIP/Ti3C2TxR sensor offers satisfactory selectivity, reproducibility and stability.

Recent Applications of Molecularly Imprinted Polymers (MIPs) on Screen-Printed Electrodes for Pesticide Detection

  • Adilah Mohamed Nageib;Amanatuzzakiah Abdul Halim;Anis Nurashikin Nordin;Fathilah Ali
    • Journal of Electrochemical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.1-14
    • /
    • 2023
  • The overuse of pesticides in agricultural sectors exposes people to food contamination. Pesticides are toxic to humans and can have both acute and chronic health effects. To protect food consumers from the adverse effects of pesticides, a rapid monitoring system of the residues is in dire need. Molecularly imprinted polymer (MIP) on a screen-printed electrode (SPE) is a leading and promising electrochemical sensing approach for the detection of several residues including pesticides. Despite the huge development in analytical instrumentation developed for contaminant detection in recent years such as HPLC and GC/MS, these conventional techniques are time-consuming and labor-intensive. Additionally, the imprinted SPE detection system offers a simple portable setup where all electrodes are integrated into a single strip, and a more affordable approach compared to MIP attached to traditional rod electrodes. Recently, numerous reviews have been published on the production and sensing applications of MIPs however, the research field lacks reviews on the use of MIPs on electrochemical sensors utilizing the SPE technology. This paper presents a distinguished overview of the MIP technique used on bare and modified SPEs for the detection of pesticides from four recent publications which are malathion, chlorpyrifos, paraoxon and cyhexatin. Different molecular imprint routes were used to prepare these biomimetic sensors including solution polymerization, thermal polymerization, and electropolymerization. The unique characteristics of each MIP-modified SPE are discussed and the comparison among the findings of the papers is critically reviewed.

Analysis of the Redox Reaction for Polypyrrole Thin Film by Using a Quartz Crystal Analyzer (수정진동자 분석기(QCA)를 이용한 폴리피롤 박막의 산화-환원반응 해석)

  • Chang, Sang-Mok;Kim, Jong-Min;Park, Ji-Sun;Son, Tae-Il;Hiroshi, Muramatsu
    • Applied Chemistry for Engineering
    • /
    • v.9 no.1
    • /
    • pp.44-51
    • /
    • 1998
  • In this work, the in-situ viscoelastic characteristics of electropolymerized polypyrrole (PPy) thin film were investigated in the electrolyte solutions of $NaClO_4$, $LiClO_4$, and $KClO_4$ by using quartz crystal analyzer (QCA). One side of quartz crystal was used as a working electrode mounted in a special fabricated QCA electrochemical ceil. The resonant frequency and resonant resistance diagram (F-R diagram) was used to interpret the viscoelastic characteristics of Pby thin film and compared with AFM photograph. The resonant frequency, resonant resistance, and current were measured to analyze the redox reaction behaviors when the cyclic voltammetry was performed using AT-cut quartz crystal electrode coated with galvanostatically polymerized Ppy film. The result suggests that the Ppy film polymerized onto the crystal behaves as a rigid elastic layer at the initial stage of electropolymerization, while the film becomes a viscoelastic layer the polymerization proceeds further. At the same time, the film thickness increases and some morphological changes take place due to the penetration of electrolyte solution into the film. These phenomena take place when cyclic voltammetry was performed using different electrolyte solution compared with polymerization process.

  • PDF