• Title/Summary/Keyword: electronic skin

Search Result 249, Processing Time 0.025 seconds

Secondary Analysis on Ventilator-Associated Pneumonia and Pressure Injury

  • Hyun, Sookyung;Moffatt-Bruce, Susan;Newton, Cheryl;Kaewprag, Pacharmon
    • International Journal of Advanced Culture Technology
    • /
    • v.6 no.3
    • /
    • pp.211-215
    • /
    • 2018
  • Ventilator-associated pneumonia (VAP) is a lung infection that develops in patients receiving mechanical ventilation. VAP contributes to about 50% of hospital-acquired pneumonia in ICU settings. One of the recommendation of the Institute of for Healthcare Improvement ventilator bundle is HOB elevation. HOB elevation affects shearing forces and makes higher risk for pressure injury development. Pressure injury (PI) is localized damage to the skin over a bony prominence. PI prevention guidelines recommend that HOB positioning should be lower to reduce risk for PI development which contradicts VAP prevention guidelines for the HOB between 30 and 45 degrees for ICU patients. This presents a care dilemma and tension. The purpose of this study was to perform a secondary data analysis using cumulative electronic health record data in order to determine the association of HOB elevation with VAP and PI in ICU patients. A secondary data analysis was conducted to determine whether HOB elevation is associated with VAP and PI. HOB elevation was not likely to be associated with VAP prevention whereas it was likely to be related to PI development. This is somewhat contrary to popular data and publications. Prospective cohort study is desired to inform us in an evidence-based fashion what actually is optimal HOB elevation for ventilated patients in ICU settings.

The Estimation of Hand Pose Based on Mean-Shift Tracking Using the Fusion of Color and Depth Information for Marker-less Augmented Reality (비마커 증강현실을 위한 색상 및 깊이 정보를 융합한 Mean-Shift 추적 기반 손 자세의 추정)

  • Lee, Sun-Hyoung;Hahn, Hern-Soo;Han, Young-Joon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.7
    • /
    • pp.155-166
    • /
    • 2012
  • This paper proposes a new method of estimating the hand pose through the Mean-Shift tracking algorithm using the fusion of color and depth information for marker-less augmented reality. On marker-less augmented reality, the most of previous studies detect the hand region using the skin color from simple experimental background. Because finger features should be detected on the hand, the hand pose that can be measured from cameras is restricted considerably. However, the proposed method can easily detect the hand pose from complex background through the new Mean-Shift tracking method using the fusion of the color and depth information from 3D sensor. The proposed method of estimating the hand pose uses the gravity point and two random points on the hand without largely constraints. The proposed Mean-Shift tracking method has about 50 pixels error less than general tracking method just using color value. The augmented reality experiment of the proposed method shows results of its performance being as good as marker based one on the complex background.

A Study on the changes of electric charge induced by Apchim (押鍼) manipulation during acupuncture therapy (자침시(刺鍼時) 압침(押鍼)의 수기자극(手技刺戟)이 전위변화(電位變化)에 미치는 영향(影響))

  • Song, Moon-Young;Shim, Won-Bo;Kim, Young-Tae;Baek, Dae-Bong;Ahn, Sung-Hun;Kim, Kyoung-Sik;Sohn, In-Cheul
    • Korean Journal of Acupuncture
    • /
    • v.22 no.4
    • /
    • pp.9-27
    • /
    • 2005
  • Objective : hypothesis. First of all, there exists electric property in meridian and meridian point. Second of all, energy flowing in meridian is related with electric property. Third of all, there is electronic interaction between the operator who performs acupuncture therapy and the receiver who is given acupuncture therapy. Forth of all, acupuncture effects may depend on the electric capacity which is transferred between the operator and the receiver via acupuncture needle. Methods : Under the hypothesis, I studied the effects of electric charge in ST37(+) and ST39(-) generated by Apchim (押鍼) manipulation which was stimulated at ST36 point. And compared with data on the changes of electric charge from the hand of the operator during acupuncture stimulation. Electric charge induced via acupuncture needle from the operator may be important factor that causes the changes of electric charge in meridian and acupoint in the receiver. Therefore we investigated the changes of electric charge induced by the operator using Maclab 400 by the following methods. The one was in stable electric circle condition and the other was in unstable electric circle condition. In this experiments, the changes of electric charge from the stimulation type of Apchim manipulation performed in our lab condition in acupuncture therapy was induced at least three factor, one was the difference of bio-potentials between the operator and the receiver of acupuncture therapy, another was the depth of acupuncture insertion from the skin of the receiver the other was an electromyogram of the receiver. Results :The data imply that the first factor should make a capacitance current when the operator touched the acupuncture needle which was inserted in the receiver. Therefore, the results suggest that capacitance currents stimulus in electronic view may be important factor in acupuncture therapy between the operator and the receiver of acupuncture therapy.

  • PDF

Study in the Development of Motion Recognition Tap-water using Ultrasonic Sensors (초음파 센서를 이용한 모션 인식 수도꼭지 개발 및 연구)

  • Kim, Dong-Hyun;Ryu, Jae-Hoo;Ju, Jong-Soo;Ahn, Jong-Pil;Kim, Jae-Wook
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.2
    • /
    • pp.309-316
    • /
    • 2022
  • Advances in technology have improved people's lives comfortably and have developed more easily, safely and simply. We usually turn on hot water to set the temperature of the water in the bathroom and gradually adjust the temperature to find the temperature we want with our skin. In this situation, I thought, "What if there is a device that can see the temperature of water with my eyes and help with the interior of the bathroom while including a safe system," and tried to create a system that values stability. For example, if a child accidentally changes the temperature of the water to high temperature while washing, he or she can get burned. And the biggest purpose is to secure better safety by adding LCDs and LEDs so that we can visually know the temperature before feeling it tactilely. As a result of the experiment, there was no error between the temperature detected by the water temperature sensor and the temperature displayed on the LCD, and no error occurred up to 27 cm in the distance measurement experiment using the ultrasonic sensor. There has been an error of about 2% since 28cm or older, but there is no significant inconvenience in using it within the category of faucets.

The Characteristics of Temperature Variation in Electronic Warm Acupuncture Device (전기식 온침기의 온도 변화 특성에 관한 연구)

  • Ja-Ha Lee;Jeong-Hyun Moon;U-Ryeong Chung;Soo-Hwa Hong;Gyoungeun Park;Byung Wook Lee;Won-Suk Sung;Jong-Hwa Yoon;Eun-Jung Kim
    • Korean Journal of Acupuncture
    • /
    • v.40 no.4
    • /
    • pp.184-193
    • /
    • 2023
  • Objectives : The purpose of this study is to understand the temperature characteristics depending on the thickness and material of the needle used with the Electronic Warm Acupuncture Device (EWAD). Methods : We controlled experimental environment and measured temperature changes of a silicon phantom in which K-type thermocouples were inserted at depths of 2, 7 mm. EWAD perfomed with acupuncture needles of various thicknesses (0.25×60 mm, 0.40×60 mm, and 0.50×60 mm) and materials (Gold 0.40×50 mm). We set non-needle (only heated with EWAD skin heater) group as a control group. Results : The maximum temperature and temperature changes of 0.40 mm, 0.50 mm needle group were significantly higher than the non-needle group. The highest temperature range in all needle groups was 0.50 mm needle group (41.44±0.31℃). However, the 0.25 mm needle group was not significantly different from the non-needle group. Maximum temperature of gold needle group was significantly higher than stainless steel needle group. Temperature changes of gold needle group were higher than stainless steel group at the depth of 7 mm. Conclusions : It was found that needle thickness and material of acupuncture had an effect on the temperature of the EWAD. When performing EWAD treatment, consideration of thickness and material of acupuncture is needed. Future research is needed using phantoms that can reflect actual clinical situations and better mimic the human body.

Verification of wrinkle improvement effect by animal experiment of suture for skin wrinkle improvement by applying CO2 gas and RF radio frequency (CO2 gas와 RF 고주파를 적용한 피부 주름 개선용 봉합사 동물 실험에 따른 주름 개선 효과 검증)

  • Jeong, Jin-Hyoung;Shin, Un-Seop;Song, Mi-Hui;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.3
    • /
    • pp.226-234
    • /
    • 2020
  • As the average life expectancy of human beings is extended in addition to the entry of the aging society, there is a tendency for the interest in the appearance of men and women in modern society to increase. The most external judgment of human aging is the wrinkles on the facial skin. People are undergoing various procedures to have clean, wrinkled, and resilient healthy skin. Many thread lifting procedures are being implemented because they tend to want simple and effective procedures during the procedure. In this study, in order to improve lifting effect in thread lifting, animal experiments were conducted to confirm the improvement of wrinkles by injecting RF high frequency and CO2 gas into existing PDO suture procedures. The experimental groups consisted of natural aging groups, PDO treatment groups, groups with RF high frequency in PDO procedures, groups with CO2 gas injected into PDO procedures, and groups with CO2 gas and RF injected simultaneously into PDO procedures. The individuals in the natural aging group had an average wrinkle depth of 0.408mm before the procedure, and the average wrinkle depth of the 10th week was 0.68mm. The depth of wrinkles in the PDO treatment group averaged 0.384mm before the procedure, and 0.348mm on the 10th week after the procedure. The average crease depth of pre-procedure objects injected with RF high frequency in PDO was 0.42mm, and the average crease depth for 10 weeks was 0.378mm. The average crease depth of the CO2 gas injected into the PDO was 0.4mm before the procedure, and the average crease depth was reduced to 0.332mm in the 10th week after the procedure. On average, the number of objects injected with CO2 gas and RF high frequency in the PDO procedure decreased to 0.412mm before and 0.338mm in the 10th week after the procedure. The procedure of injecting CO2 gas and RF into the PDO suture showed the highest reduction rate of 17.96%.

Developed an output device for high-frequency cosmetic medical equipment using micro multi-needle (마이크로 멀티니들을 이용한 고주파 피부미용 의료기기를 위한 출력 장치 개발)

  • Kim, Jun-tae;Joo, Kyu-tai;Cha, Eun Jong;Kim, Myung-mi;Jeong, Jin-hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.394-402
    • /
    • 2021
  • The entry of an aging society and the extension of human life expectancy, the increasing interest in women's social advancement and men's appearance, and the natural interest in K-culture through media media, while receiving worldwide attention, Focus on K-Bueaty. Recently, looking at the occupation of the medical tourism field, in the case of aesthetic medicine tourism such as molding and dermatology, it has gained popularity not only in Asia such as China and Japan, but also in North America and Europe. The first external confirmation of human aging is the wrinkles on the skin of the face. Clean, wrinkle-free, elastic and healthy skin is a desire of most people. Skin condition and condition such as focused ultrasonic stimulation (HIFU: High Intensity Focused Utrasound) and low frequency, high frequency (RF: Radio Frequency), galvanic therapy using microcurrent, cryotherapy using rapid cooling, etc. Depending on the method of management, the effect of the treatment differs depending on the output and the stimulation site, etc., even in the treatment of medical equipment and beauty equipment using the same mechanism. In this research, in order to develop invasive high-frequency dermatological devices using a large number of beauty medical devices and microneedles of beauty devices, the international standards IEC 60601-2 (standards for individual medical devices) and MFDS (Ministry of) We designed and developed a high-frequency output device in compliance with the high-frequency stimulation standard announced in the Food and Drug Safety (Ministry of Food and Drug Safety). The circuit design consists of an amplifier (AMP: Amplifier) using Class-A Topology and a power supply device using Half-Bridge Topology. As a result of measuring the developed high-frequency output device, an average efficiency of 63.86% was obtained, and the maximum output was measured at 116.7W and 50.67dBm.

Review of Clinical and Experimental Studies on External Application Treatment for Atopic Dermatitis in the Korean Literature (아토피 피부염 외용제에 관련된 국내 임상 및 실험 논문 고찰)

  • Min, Deul Le;Park, Eun Jung;Kang, Kyung Ha
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.27 no.1
    • /
    • pp.36-49
    • /
    • 2013
  • Objectives The goal of this review is to investigate clinical and experimental studies on external application treatment for atopic dermatitis in Korean literature and to propose for the better method of clinical studies in order to seek more effective treatment. Methods Electronic researches were performed with KTKP, OASIS, National Assembly Library, Korean Medicine Database, KISS, DBpia, and KISTI. Results and Conclusions In Twenty six studies, the numbers of clinical and experimental studies are respectively 10 (38.46%) and 16 (61.54%). The numbers of studies that used herbal complex were 20 (76.92%), and out of that, 6 studies had used a single herbal medicine (23.08%). The external application with oriental medicine for the atopic dermatitis used with Phellodendri Cortex (7), Sophorae Radix (6), Scutellariae Radix (6), Lonicerae Flos (5), Coptidis Rhizoma (5) and so on. Among the clinical studies, the 5 studies were double-blind and randomized-controlled study (50%). The numbers of studies that used Hanifin and Rajka Diagnostic Criteria (1980) were 6 (60%), and that used the Diagnostic Criteria in Korean Atopic Dermatitis (2005) were 4 (40%). Among the clinical studies, categories to evaluate of atopic dermatitis are respectively SCORAD Index (80%), Total IgE (80%), Eosinophil count (70%) and so on. All of the clinical studies (100%) showed a statistically significant decline in atopic dermatitis according to the SCORAD Index, Modified SCORAD Index, the Clinic index score. Among the experimental studies, the numbers of studies that used NC/Nga mice were 9 (56.25%), and out of that 5 studies used BALB/c mice (31.25%). Most of the studies (68.75%) used DNCB as allergy inducing materials. The scales for evaluation of atopic dermatitis were Clinical skin severity score, Histopathologic examination, Immunohematologic examination, safety test and so on. In 12 cases (75%) of experimental studies, the IgE level of experimental group showed a statistically significant decline after using external application. In 8 study cases (50%), Clinical skin severity score of experimental group showed a statistically significant decline after using external application.

Prevalence of common medical disorders among dog breeds examined in primary-care veterinary clinics at Jeollabuk-Do, Republic of Korea (전라북도 지역 동물병원에 내원한 반려견의 주요 품종별 질환 양상 조사)

  • Kim, Eunju;Choe, Changyong;Yoo, Jae Gyu;Oh, Sang-Ik;Jung, Younghun;Cho, Ara;Kim, Suhee;Do, Yoon Jung
    • Korean Journal of Veterinary Service
    • /
    • v.41 no.2
    • /
    • pp.97-104
    • /
    • 2018
  • Recently, demographic studies of veterinary medical database have been conducted to understand patterns of disease occurrence. Understanding incidence of breed-related disease would provide appropriate guidance for future health care strategies and offer useful information for early diagnosis of disease. However, in veterinary medicine, theses research has not yet been investigated in the Republic of Korea. The purpose of this study was to investigate the prevalence of common medical disorders among dog breeds examined at primary-care veterinary clinics in Jeollabuk-Do, Republic of Korea. The data were analyzed based on World Health Organization's International Classification of Disease. A total 13,176 medical records of canine patients were analyzed from six primary veterinary clinics in Jeollabuk-Do from January to December 2016. Results showed that the most common health problems were 'disease of skin' (17.7%); followed by 'diseases of digestive system' (12.26%), 'preventive medicine' (10.08%), and 'diseases of ear and mastoid process' (10.4%). In seven out of ten breeds, the most common medical disorder was skin disease. For poodle such as Pomeranian and Chihuahua, digestive system disease was most prevalent. On the other hand, respiratory system disease was found to be higher in Pomeranian than other breeds; while ear and mastoid process disease was most common for Maltese and Poodle. This study can help owners, breeders, and veterinarians prevent and manage various diseases of popular breeds in Jeollabuk-Do in the future.

A Study on the Comparison of Detected Vein Images by NIR LED Quantity of Vein Detector (정맥검출기의 NIR LED 수량에 따른 검출된 정맥 이미지 비교에 관한 연구)

  • Jae-Hyun, Jo;Jin-Hyoung, Jeong;Seung-Hun, Kim;Sang-Sik, Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.485-491
    • /
    • 2022
  • Intravenous injection is the most frequent invasive treatment for inpatients and is widely used for parenteral nutrition administration and blood products, and more than 1 billion procedures are used for peripheral catheter insertion, blood collection, and other IV therapy per year. Intravenous injection is one of the difficult procedures to be performed only by trained nurses with intravenous injection training, and failure can lead to thrombosis and hematoma or nerve damage to the vein. Accordingly, studies on auxiliary equipment capable of visualizing the vein structure of the back of the hand or arm are being published to reduce errors during intravenous injection. This study is a study on the performance difference according to the number of LEDs irradiating the 850nm wavelength band on a vein detector that visualizes the vein during intravenous injection. Four LED PCBs were produced by attaching NIR filters to CCD and CMOS camera lenses irradiated on the skin to acquire images, sharpen the acquired images using image processing algorithms, and project the sharpened images onto the skin. After that, each PCB was attached to the front end of the vein detector to detect the vein image and create a performance comparison questionnaire based on the vein image obtained for performance evaluation. The survey was conducted on 20 nurses working at K Hospital.