• Title/Summary/Keyword: electronic equipment

검색결과 1,548건 처리시간 0.027초

Analysis of Geospatial Information Construction Efficiency by 3D Laser Scanner Integrated with Total Station (3D 레이저 스캐너와 토털스테이션 통합에 의한 공간정보 구축의 효율성 분석)

  • Park, Joon-Kyu;Lee, Keun-Wang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제18권12호
    • /
    • pp.638-643
    • /
    • 2017
  • The 3D laser scanner operates by measuring the distance from the sensor to the target and operates on the same principle as Electronic Distance Measuring (EDM). Recently, 3D laser scanning technology has been rapidly developed in line with the strongly increasing demand for 3D information acquisition. Therefore, it is now possible to more easily acquire geometric information of various objects existing in real space. In this study, we constructed geospatial information by using new equipment which integrated 3D laser scanner and total station, and we suggest the possibility of using new technology for geospatial information construction by comparing and analyzing with existing methods. In the study result, we demonstrated the efficiency of the geospatial information constructed by integration of 3D laser scanner and total station. The proposed method is expected to shorten the time required for data acquisition compared to the existing method using the existing total station. Furthermore, it is possible to use various methods such as cross section analysis and volume calculation using the acquired data. In the future, spatial information construction by integration of 3D laser scanner and total station will help improve work efficiency in related fields.

Comparative Analysis of pre and Post Digital X-ray Equipment Construction and Web-Based Wireless Network Environment Construction for Medical Screening Vehicles (Digital X-ray장비 구축 검진차량의 웹 기반 무선 네트워크 환경 구축 전과 후의 비교분석)

  • Ryu, Young-Hwan;Kweon, Dae-Cheol;Goo, Eun-Hoe;Dong, Kyung-Rae;Choi, Sung-Hyun;Jang, Young-Ill
    • Korean Journal of Digital Imaging in Medicine
    • /
    • 제12권2호
    • /
    • pp.103-111
    • /
    • 2010
  • A total of 200 hospital employees participated in this study from January 2009 to June 2010. For the survey, each participant was given necessary items for external health exams. Cronbach's alpha was calculated for the survey regarding wireless networks. There was a need for educating data processing workers in the medical field regarding fundamental information prior to wireless network construction. The reason is high scores would be collected, which would reflect knowledge regarding data processing used at hospitals and the differences between paper charts and electronic charts. However, low scores were obtained which reflected knowledge regarding the differences between wired and wireless networks and Mini-PACS. Time for each patient was shortened to a maximum of three minutes and minimum of one minute for treatment and transmitting medical images when comparing pre and post wireless network construction(p < 0.01). Scores from the pre and post construction survey increase 1.98, 1.65, and 1.43 points for activity in the health screening area, usage of space in the health screening vehicle, and patient information storage respectively(p < 0.05). The number of patients receiving external health screenings twelve times was 3,655 prior to construction of a wireless network system. However, the number increased to 4,265 after construction. The increasing percentage was 17% in total. Prior to construction, X-ray images were taken 527 times, but after construction of a wireless network, this number growed to 1,194 and it was 116% increase. The loss of patient's medical treatment charts was reduced from 19.8% to 18.7% after construction. We believe that educating medical workers on Mini-PACS and Mini-OCS Systems will not only increase their efficiency but also make patients receiving better treatment.

  • PDF

A Study on the Design of DICOM Integration Engine in the Ubiquitous Computing Environments (유비쿼터스 컴퓨팅 환경에서의 DICOM 설계에 대한 연구)

  • Im, In-Chul;Ha, An-Rye;Kim, Chang-Soo;Hwang, In-Chul;Ok, Chi-Sang
    • Journal of radiological science and technology
    • /
    • 제28권4호
    • /
    • pp.307-315
    • /
    • 2005
  • In the ubiquitous computing environments, ICT industries of current society are developed in enormous growth. Medicine or patients with mobile devices can access at any time, any place. The medical procedures at the patient bedside are out of the scope of current systems, which means that patient record and image data access during the medical visit or the execution, recording and confirmation of the medicine prescriptions, still do not enjoy computerized support. Today, the exchange of medical images and clinical information is well defined by DICOM and HL7 standards. The DICOM independent terminal equipment image access system was developed in which a DICOM Engine acts as the gateway between a PACS DB and user's terminal. Implementation system is compatible with most currently available Integration system models. This paper presents a software technology where the medical and nursing staff will be equipped with any device connected by wire and wireless to a central server that provides access to the electronic patient records and that will actively inform about tasks pending distribution. The prototype described in this article implements a medical images and structured reports server that makes the search and recovery of data stored in the DICOM standard possible.

  • PDF

Exposure Dose of Thyroid, Breast, and Sexual Gland using a Personal Dosimeter in Multiple CT Examinations (다중 CT 검사 시 개인선량계를 이용한 갑상선, 유방, 생식선의 피폭선량)

  • Kim, Hae-Suk;Kim, Jang-Oh;Lee, Yoon-Ji;Heo, Sung-Hoe;Lee, Chang-Ho;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • 제14권4호
    • /
    • pp.345-351
    • /
    • 2020
  • In this study, a dose assessment was conducted on the exposure dose of thyroid, breast and sexual gland using a personal dosimeter in multiple CT examinations currently being conducted in health examinations. The dose assessment was measured by attaching TLD and EPD to the locations of the thyroid, breast and sexual gland during CT examinations of Brain, Brain + C-S, Brain + Low lung, Brain + L-S among CT items. The generated dose of equipment, CTDIvol and DLP, was measured. The study found that effective doses were rated 41.7% higher for thyroid TLD in Brain + C-S CT examinations than for the general public, 156% higher for EPD, 10% for breast EPD in Brain + Low Lung CT examinations, 124.4% higher for reproductive TLD and 339.8% higher for Brain + L-S CT examinations. The CTDIvol and DLP analysis results showed that C-S CTDIvol values were higher than the diagnostic reference levels at 0.6%, Low Lung CTDIvol values at 5.7%, DLP values at 11.8% and L-S CTDIvol values at 1.2%. In order to reduce the exposure dose of patients, indiscriminate examination is reduced and dose limit setting is needed in health examination.

Nickel Film Deposition Using Plasma Assisted ALD Equipment and Effect of Nickel Silicide Formation with Ti Capping Layer (Plasma Assisted ALD 장비를 이용한 니켈 박막 증착과 Ti 캡핑 레이어에 의한 니켈 실리사이드 형성 효과)

  • Yun, Sang-Won;Lee, Woo-Young;Yang, Chung-Mo;Ha, Jong-Bong;Na, Kyoung-Il;Cho, Hyun-Ick;Nam, Ki-Hong;Seo, Hwa-Il;Lee, Jung-Hee
    • Journal of the Semiconductor & Display Technology
    • /
    • 제6권3호
    • /
    • pp.19-23
    • /
    • 2007
  • The NiSi is very promising candidate for the metallization in 45 nm CMOS process such as FUSI(fully silicided) gate and source/drain contact because it exhibits non-size dependent resistance, low silicon consumption and mid-gap workfunction. Ni film was first deposited by using ALD (atomic layer deposition) technique with Bis-Ni precursor and $H_2$ reactant gas at $220^{\circ}C$ with deposition rate of $1.25\;{\AA}/cycle$. The as-deposited Ni film exhibited a sheet resistance of $5\;{\Omega}/{\square}$. RTP (repaid thermal process) was then performed by varying temperature from $400^{\circ}C$ to $900^{\circ}C$ in $N_2$ ambient for the formation of NiSi. The process temperature window for the formation of low-resistance NiSi was estimated from $600^{\circ}C$ to $800^{\circ}C$ and from $700^{\circ}C$ to $800^{\circ}C$ with and without Ti capping layer. The respective sheet resistance of the films was changed to $2.5\;{\Omega}/{\square}$ and $3\;{\Omega}/{\square}$ after silicidation. This is because Ti capping layer increases reaction between Ni and Si and suppresses the oxidation and impurity incorporation into Ni film during silicidation process. The NiSi films were treated by additional thermal stress in a resistively heated furnace for test of thermal stability, showing that the film heat-treated at $800^{\circ}C$ was more stable than that at $700^{\circ}C$ due to better crystallinity.

  • PDF

Practical Usage of Low-Temperature Metal Catalyst for the Destruction of Volatile Organic Compounds (VOCs) (휘발성 유기화합물(VOCs) 제거를 위한 저온금속촉매 실용화에 관한 연구)

  • Jung, Sung-Chul;Lee, Seung-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제34권6호
    • /
    • pp.397-405
    • /
    • 2012
  • In this study, performance evaluation of newly developed technology for the economical and safe removal of volatile organic compounds (VOCs) coming out from electronic devices washing operation and offensive odor induction materials was made. Metal oxidization catalyst has shown 50% of removal efficiency at the temperature of $220^{\circ}C$. Composite metal oxidization catalyst applied in this study has shown that the actual catalysis has started at the temperature of $100^{\circ}C$. Comprehensive analysis on the catalyst property using Mn-Cu metal oxidization catalyst in the pilot-scale unit was made and the removal efficiency was variable with temperature and space velocity. Full-scale unit developed based on the pilot-scale unit operation has shown 95% of removal efficiency at the temperature of $160^{\circ}C$. Optimum elimination effective rates for the space velocity was found to be $6,000hr^{-1}$. The most appropriate processing treatment range for the inflow concentration of VOCs was between 200 ppm to 4,000 ppm. Catalyst control temperature showed high destruction efficiency at $150{\sim}200^{\circ}C$ degrees Celsius in 90~99%. External heat source was not necessary due to the self-heat reaction incase of VOCs inflow concentration is more than 1,000 ppm. Equipment and fuel costs compared to the conventional RTO/RCO method can be reduced by 50% and 75% respectively. And it was checked when there was poisoning for sulfide and acid gas.

A Study on the SAR Measurement System Validation at 150 MHz Band (150 MHz 대역에서의 SAR 측정시스템의 유효성 연구)

  • Choi, Donggeun;Kim, Kihwea;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제24권10호
    • /
    • pp.1008-1016
    • /
    • 2013
  • SAR measurement which was applied only to the mobile phone has been expanded in the Korean radio regulation law to the portable wireless communication equipments within 20 cm from the human body since Jan. 2012. The two-way radio operating at 150 MHz frequency band was newly included following the revised radio regulation in the target equipment of measurement. SAR measurement system at 150 MHz satisfying this regulation is necessary accordingly for SAR conformity assessment. The international SAR measurement standard(IEC 62209-2) includes the evaluation method on frequencies above 300 MHz, and the commercial SAR measurement system can measure SAR above 300 MHz only. The size of the reference dipole antenna(760 mm, return loss: -27.57 dB) and flat phantom ($1,300 mm(L){\times}900 mm(W){\times}200 mm(H)$), targeted SAR values for numerical analysis(1 g: 1.08 W/kg, 10 g: 0.77 W/kg) for SAR validation evaluation at 150 MHz frequency are proposed in this paper. The suggested dipole antenna and flat phantom are assembled and used to verify the conformity assessment of commercial SAR measurement system. The measured SAR values of 1 g and 10 g were obtained respectively to be 1.13 W/kg, 0.81 W/kg, and they satisfied the effective range(within ${\pm}10$ %) of IEC international standard. The standards based on this study are expected to be used for the domestic SAR measurement standard and IEC(International Electrotechnical Commission) international standard.

An Experimental Study on the Effect of Supporting Vest for Musculoskeletal Disorders in Low Back (허리 근골격계질환 예방 보조 조끼의 효과에 대한 실험적 연구)

  • Kim, Yun-Jeong;Jang, Jee-Hun;Cho, Yoe-han;Jeong, Jin-Hyoung;Cheong, Ha-Young;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • 제13권3호
    • /
    • pp.219-225
    • /
    • 2020
  • With the aging population, the prevalence of musculoskeletal disorders in the elderly continues to increase. In addition, musculoskeletal disorders are the third most common social and economic loss among occupational illnesses in Workers' compensation insurance benefits as of 2015 standard and are also common among workers. In this study, a vest that can assist in the prevention and treatment of musculoskeletal disorders of the waist was produced, and it is intended to confirm the presence or absence of the effect through experiments. Diseases of the waist are closely related to core muscles. Therefore, the produced vest was made in a form that supports the core muscles. Before and after wearing the vest for effectiveness verification, the While performing 10-times of the Mackenzie exercises, a waist extension exercise, collected the EMG data of the internal oblique, Rectus abdominis, and Erector spinae, which correspond to the core muscles. The collected data were analyzed through the electromyography analysis program RM-3 to obtain RMS values for 10-times measurements of each muscle and to compare the average values. After comparing the data, to verify the significance, the technical statistical value of the measurement result was calculated and the average difference was verified through PASW ver18.0, And the paired t-test is performed on the experimental results to perform statistical processing. and Statistical processing was performed by setting the significance level to α=.05.

Development of the Standard Model of a Stated Period Check and Precise Safety Diagnosis in the Research Lab for Prevention to Electrical Accidents (전기사고방지를 위한 연구실험실 정기점검/정밀안전진단 표준모델개발)

  • Lee, Dong-Yoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제12권2호
    • /
    • pp.858-864
    • /
    • 2011
  • There is no standard model for a Stated Period Check and a Precise Safety Diagnosis to remove electric fire and shock in the university Lab and institute. Especially, the research for the Stated Period Check and the Precise Safety Diagnosis of the Lab related to electrical field is very weak currently, and it is very necessary to build a detail safety plan. This paper informs the specific standard guideline of the safety check list, method and equipment and it shows the way to evaluate safety grade too. This paper also provides the information of R&D process through the analysis of electrical safety check list of ordinary R&D Lab. It shows a new detail guideline to R&D Lab, and the new guideline removes existing problem and deliver the effective standard model to each R&D Lab. The standard model developed in this research adopts the clear guideline of each check list for the electrical environment of current R&D Lab. This standard model can be applied for every R&D Lab to detect routine safety check and detail safety check immediately. This Research will generally improve not only the effective safety check, but also the safety level for R&D Lab to prevent the electrical accidents.

A Basic Study on Sorting of Black Plastics of Waste Electrical and Electronic Equipment (WEEE) (폐가전의 검정색 플라스틱 재질선별에 관한 기초 연구)

  • Park, Eun Kyu;Jung, Bam Bit;Choi, Woo Zin;Oh, Sung Kwun
    • Resources Recycling
    • /
    • 제26권1호
    • /
    • pp.69-77
    • /
    • 2017
  • Used small household appliances(small e-waste) consists of a variety of complex materials and components. The small e-waste is mainly composed of plastics and an important potential source of waste plastic. The black plastics, particularly are very difficult to separate by resin type and therefore these are mainly recycled in the form of a mixtures. In the present study, the sorting technologies such as gravity and electro static separation, near-infrared ray(NIR) and IR/Raman optical sorting separation on mixture of black plastics were analyzed and their limitations on sorting process were also investigated. The Laser Induced Breakdown Spectroscopy(LIBS) spectrum of each black plastics was used for identification of black plastics by resin type, and after analyzing the normalization operation, Principal Component Analysis(PCA) was carried out. The spectrum data was optimized through PCA process. In order to improve the identification accuracy and sorting efficiency of black plastics, it is necessary to design a classifier with high efficiency and to improve the performance and reliability of the classifier by applying the field of intelligent algorithms.