The electron-capture detector (ECD) of gas chromatographs (GC) has been used widely in pesticide analysis. However, as ECD relies on radioactive material, it is troublesome to purchase and maintain. Therefore, potent replacements for ECD were investigated. A Pulsed-discharge detector (PDD) for ECD was tested and the analytical results of PDD (ECD mode), ${\mu}ECD$, and nitrogen-phosphorus detector (NPD) were compared for 107 pesticides including organochroline, organophosphorus, pyrethroids etc. The number of pesticides identified at the lowest limit of detection (LOD) was 36, 29, and 2 for PDD, ${\mu}ECD$, and NPD, respectively. The remaining pesticides showed same response to PDD and ${\mu}ECD$. The GC-PDD analysis of pesticides spiked into representative agricultural products (brown rice, spinach, and mandarin oranges) also showed good and/or equivalent recoveries using $GC-{\mu}ECD$.
Pesticide residues were extracted with 70% acetone and transferred to dichloromethane. Extracts were applied to open-column chromatography with florisil and alumina-N. The final extract was analyzed by gas chromatography with electron-capture detector(GC /ECD) and nitrogen-phosphorus detector(GC/NPD). Recoveries of the 17 organochlorine pegticides were ranged from 60.8 to 84.9% and those of 15 organophosphate pesticides, from 70.5% to 100.0%(except phosmet and azlnphos-methyls. The minimum detectable levels of this analytical method were low(0.021-0.058mg/kg).
Proceedings of the Korean Society of Soil and Groundwater Environment Conference
/
2005.04a
/
pp.199-201
/
2005
This paper describes a simple procedure for the quantitative analysis of 7 PCBs (polychlorinated biphenyls) in soils on the waste reclaimed land, The procedure involved sample clean up using silicagel column, acetonitrile partition and sulfuric acid procedures. The instrumental technique is applied GC/PDD(gas chromatography/pulsed discharge detector) and GC/ECD(gas chromatography/electron capture detector). Concentration of $sub-{\mu}g/g$ level was attainable with 20g soils on the waste reclaimed land.
A selective and sensitive method for the derivatization of total homocysteine (Hcy) and the related compounds in plasma by gas chromatograph (GC)-electron capture detector (ECD) has been developed. To determine total homocysteine, cysteine (Cys), and methionine (Met) in human plasma using GC-ECD, analytes were reduced and converted into their N(O,S)-ethylearbonyl pentafluoropropyl (PFP) ester by derivatization with ethyl chloroformate and pentafluoropropyl alcohol (PFP-OH) in plasma. The best derivatizing agent N(O,S)-ethyl carbonyl PFP ester, was chosen by comparing the sensitivity of derivatized analysis in GC-ECD. The derivatized analytes in plasma were extracted by chloroform, and subsequently back-extracted with hexane and analyzed by GC-ECD. The calibration carves ($R^2$ > 0.990) were linear over the range $5-50{\mu}mol/L$ of Hcy and Met, $40-400{\mu}mol/L$ of Cys spiked in plasma. The detection limit observed by the established method was below $0.5{\mu}mol/L$. This method is highly sensitive and specific in the analysis of Hcy, Cys, and Met. Therefore, we suggest that this method is appropriate in the analysis of trace concentration of Hcy, Cys, and Met in biological fluids.
To investigate the optimum condition of 3-monochloro-1, 2-propanediol(MCPD) analysis, gas chromatography with electron capture detector was used. Determination of MCPD derivatized with phenylboric acid was more effective than that of underivatized MCPD. In derivatization of MCPD with phenyl boric acid, there were no significantly different between boiling for 2min at 9$0^{\circ}C$ and vortexing for 5min at room temperature. Extrelut column was suitable for extraction of MCPD diluted in 20% NaCl solution and recovery rates were higher than direct extraction of MCPD with ethyl acetate. But, the method of direct extraction of MCPD with ethyl acetate was useful for rapid ants qualitative analysis. The sample extracted in soysauce(ganjang) was derivatized with phenylboric acid and analyzed by gas chromatography-mass selective detector. That was confirmed as MCPD-phenylboronate.
Proceedings of the Korean Environmental Sciences Society Conference
/
1997.10a
/
pp.37-39
/
1997
Pesticide residues were extracted with 70% acetone and transferred to dichloromethane. Extracts were applied to open-column chromatography with florisil and alumina-N, The final extract was analyzed by gas chromatography with electron-capture detector(GC/ECD) and nitrogen-phosphorus detector(GC/NPD). Recoveries of the 17 organochlorine pesticides were ranged from 60.8 to 84.9% and those of 15 organophosphorus pesticides, from 70.5 to 100.0%(except phosmet and azinphos-methyl). The minimum detectable levels of this analytical method were low (0.021-0.058 mg/kg).
The simultaneous analytical method for 37 residual pesticides was developed by a gas chromatography with $^{63}$ Ni electron capture detector. Pesticides added in soybean sample were extracted with 70% acetone in water and methylene chloride in oder, and then cleaned up via open-column apparatus packed with florisil and alumina N. The Ultra-2 fused capillary column was used to separate the products. The resolution between the last isomeric peak of cypermethrin (56.398 min) and the first isomeric peak of flucythrinate (56.421 min) was not satisfactory and the last isomeric peak of fenvalerate(58.783 min) and the first isomeric peak of fluvalinate(58.835 min) was overlapped. Except for $\alpha$-BHC, dichlofluanid, captan, and captafol, most recoveries were showed over 70%.
For the risk assessment of human exposure to volatile halogenated hydrocarbons, a dynamic purge trap/on-column cryofocusing method using capillary gas chromatograph-$^{63}Ni$ electron capture detector and thermal desorption unit was applied to analyze the free forms, metabolites of 1, 1, 2-trichloroethylene and 1, 1, 2, 2-tetrachloroethylene. The urine sample was diluted with distilled water, hydrolyzed and sealed. Then the inert gas was infused to purge out free 1, 1, 2-trichloroethylene, free 1, 1, 2, 2-tetrachloroethylene and urichloroethanol. These compounds were trapped to $Tenax^R$ / GC-gas trap device throughout clean up tube. Being undertectable to gas chromatograph directly, trichloroacetic acid was methyl esterificated and trapped in the manner above mentioned. The optimal incubation time to get best recovery of methyl ester was 4 hours at $60^circ$C. The concentrations of free volatile halogenated hydrocarbons and their metabolites in urine were obtained of free volatile halogenated hydrocarbons and their metabolites in urine were obtained from 5 healthy volunteers. This analytical method is expected to make the biological monitoring more precise and convenient.
An, Jung-Hyeok;Lee, Seog-Jong;Lee, Woan;Kim, Joon-Bum;Lee, Gwang-Chun;Kwon, Young-Du;Jeon, Choong;Park, Kwang-Ha
Analytical Science and Technology
/
v.19
no.2
/
pp.155-162
/
2006
In this study, a series of experiments were conducted using a standard solution containing ${\alpha}$ and ${\beta}$-endosulfan to follow the removal effect of residual pesticides on soil and aqueous solution. An analytical method for residual pesticides was established by a gas chromatography equipped Ultra II[$(30m{\times}0.25mm(ID){\times}0.25{\mu}m$] capillary column and a ${\mu}$-electron capture detector(${\mu}$-ECD). Recovery rates of residual pesticides for soil samples were 96-100%. The amount of ${\alpha}$ and ${\beta}$-endosulfan that was spread in the soil was checked for various period of time. It indicated that the amount was reduced to 73 and 61%, respectively. When the water spread amount increased from 10 to 100 mL, ${\alpha}$-endosulfan was eliminated from 45 to 85% and while ${\beta}$-endosulfan from 44 to 88%. Removal rates of ${\alpha}$-endosulfan and ${\beta}$-endosulfan were 99% and 98% respectively within 30 minutes. It was assumed that the organic salts and strong alkali elements contained in the pesticide degradator hydrolyzed the residual pesticide.
Sohn H. J.;Lee S. K.;Cho B. G.;Kim S. J.;Lee N. Y.;Choi D. S.;Jeong M. S.;Bae H. R.;Yang J. W.
Proceedings of the Ginseng society Conference
/
2002.10a
/
pp.238-252
/
2002
In order to screen out indicators for the discrimination of ginseng habitat, some physical and chemical characteristics of Korean red ginsengs (94 kinds) and Chinese red ginsengs (50 kinds) were analyzed by using a rheometer, an electronic nose system, a combined technique of solid phase micro-extraction (SPME) and gas chromatograph equipped with an electron capture detector (GC/ECD), an X-ray fluorescence spectrometer (XRF), an inductively coupled plasma mass spectrometer (ICP/MS), a near infrared spectrometer (NIRs) and high performance liquid chromatography equipped with evaporative light scattering detector (HPLC/ELSD). The results are summarized as follows: (i) The rhizome strengths of Korean red ginsengs were significantly higher than those of Chinese red ginsengs. (ii) The electronic nose patterns of Korean red ginsengs were significantly different from those of Chinese red ginsengs. (iii) Some unidentified peaks were detected not in the headspace of Korean red ginsengs but in the headspace of Chinese red ginsengs when the headspace volatiles prepared by the SPME technique were analyzed by GC/ECD. (iv) Either the content ratios of K to Ca or Mn to Fe were significantly different between Korean red ginsengs and Chinese red ginsengs. (v) The reflectance ratios of NIRs wavenumbers such as $904\;cm^{-1}\;to\;1088\;cm^{-1}$ for Korean red ginsengs were significantly different from those for Chinese red ginsengs. (vi) The content ratios of ginsenoside-Rg to ginsenoside-Re of Korean red ginsengs were significantly higher than those of Chinese red ginsengs. These results indicate that the rhizome strength, the electronic nose pattern, the occurrence of ECD-sensitive headspace volatile components, the content ratios of K to Ca and Mn to Fe, the NIRs pattern and the content ratio of ginsenoside-Rg to -Re may be indicators for the discrimination of ginseng habitat.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.