• Title/Summary/Keyword: electron cyclotron resonance (ECR)

Search Result 91, Processing Time 0.025 seconds

Construction of an Electron Cyclotron Resonance Plasma Apparatus (ECR 플라즈마 장치의 제작)

  • 오수기;정근모
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.1
    • /
    • pp.32-36
    • /
    • 1992
  • An ECR plasma apparatus is designed and constructed. The gradient of magnetic field in microwave cavity was adjusted to provide an ECR plasma stream by electro magnetic lenz system. Employing a yoke arround the electro magnets, the magnetic field intensity was increased by 50% with the same electric current. Characteristics of the ECR plasma discharged in the apparatus were investigated by Langmuir probe method. The variations of electron temperature and electron density along chamber axis were analysed.

  • PDF

Growth and Electrical Characteristics of Ultrathin $SiO_2$ Film Formed in an Electron Cyclotron Resonance Oxygen Plasma (ECR 산소 플라즈마에 의한 $SiO_2$ 박막의 성장 거동 및 전기적 특성)

  • 안성덕;이원종
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.3
    • /
    • pp.371-377
    • /
    • 1995
  • Silicon oxide films were grown on single-crystal silicon substrates at low temperatures (25~205$^{\circ}C$) in a low pressure electron cyclotron resonance (ECR) oxygen plasma. The growth rate of the silicon oxide film increased as the temperature increased or the pressure decreased. Also, the thickness of the silicon oxide film increased at negative bias voltage, but not changed at positive bias voltage. The growth law of the silicon oxide film was approximated to the parabolic form. Capacitance-voltage (C-V) and current density-electric field (J-E) characteristics were studied using Al/SiO2/p-Si MOS structures. For a 10.2 nm thick silicon oxide film, the leakage current density at the electric field of 1 MVcm-1 was less than 1.0$\times$10-8Acm-2 and the breakdown field was higher than 10 MVcm-1. The flat band voltage of Al/SiO2/p-Si MOS capacitor was varied in the range of -2~-3 V and the effective dielectric constant was 3.85. These results indicate that high quality oxide films with properties that are similar to those of thermal oxide film can be fastly grown at low temperature using the ECR oxygen plasma.

  • PDF

Effects of electrode configurations on uniformity of copper films on flexible polymer substrate prepared by ECR-MOCVD (ECR-MOCVD에 의해 연성 고분자 기판에 제조된 구리막의 균일도에 전극의 형태가 미치는 영향)

  • 전법주;이중기
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.34-46
    • /
    • 2004
  • Copper films were prepared by using ECR-MOCVD(Electron Cyclotron Resonance Metal Organic Chemical Vapor Deposition) coupled with a DC bias system. The DC bias is connected to the electrode which placed 1∼3cm above the polymer substrate. The pulse electrical field around the electrode attracts the positive charged copper ions generated from the dissociation of copper precursor, $Cu(hfac)_2$, under ECR plasma. Condensation of supersaturated copper ions in the space between the electrode and substrate, makes it possible to deposit copper film on the polymer substrate even at room temperature. In this study, optimization of the electrode configuration was carried out in order to obtain the uniform films. The uniformity of the deposited films were closely related to the parameters of electrode geometry such as electrode shape, thickness, grid size and the spacing between electrodes. The most uniform copper film was observed with the electrode that enabled uniform electrical field distribution across the whole dimension of electrode.

A Study on the Optimal Magnet for ECR (ECR 용 최적 마그네트에 관한 연구)

  • Kim, Y.T.;Kim, Y.J.;Kim, K.S.;Lee, Y.J.;Son, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.649-652
    • /
    • 1992
  • ECR(Electron Cyclotron Resonance) occure at ${\omega}_c$=${\omega}$, ${\omega}_c$:electron cycltron frequency, ${\omega}$:electromagnetic wave frequency. ECR system have several merit, 1) power transefer efficiency 2) low neutral gas pressure (below 1 mTorr) 3) high plasma density($10^{12}$ $cm^{-3}$). It is applicated variously in the field of semiconductor and new materials as the manufacturing equipment. Magnetic field in ECR system contruct resonance layer (${\omega}$=2.45GHz, $B_z$=875 Gauss) and control plasma. Plasma is almost generated at resonance layer. If the distance between substrate and resonance layer is short, uniformity of plasma is related with profile of resonance layer. Plasma have the property "Cold in Field", so directonality of magnetic field is one of the control factors of anisotropic etching. In this study, we calculate B field and flux line distribution, optimize geometry and submagnet current and improve of magnetic field directionality (99.9%) near substrate. For the purpose of calculation, vector potential A(r,z) and magnetic field B(r,z), green function and numerical integration is used. Object function for submagnet optimization is magnetic field directionality on the substrate and Powell method is used as optimization skim.

  • PDF

Experimental Research of an ECR Heating with R-wave in a Helicon Plasma Source

  • Ku, Dong-Jin;An, C.Y.;Park, Min;Kim, S.H.;Wang, S.J.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.274-274
    • /
    • 2012
  • We have researched on controlling an electron temperature and a plasma collision frequency to study the effect of collisions on helicon plasmas. So, we have designed and constructed an electron cyclotron resonance (ECR) heating system in the helicon device as an auxiliary heating source. Since then, we have tried to optimize experimental designs such as a magnetic field configuration for ECR heating and 2.45GHz microwave launching system for its power transfer to the plasma effectively, and have characterized plasma parameters using a Langmuir probe. For improving an efficiency of the ECR heating with R-wave in the helicon plasma, we would understand an effect of R-wave propagation with ECR heating in the helicon plasma, because the efficiency of ECR heating with R-wave depends on some factors such as electron temperature, electron density, and magnetic field gradient. Firstly, we calculate the effect of R-wave propagation into the ECR zone in the plasma with those factors. We modify the magnetic field configuration and this system for the effective ECR heating in the plasma. Finally, after optimizing this system, the plasma parameters such as electron temperature and electron density are characterized by a RF compensated Langmuir probe.

  • PDF

Study on the Fabrication and Characterization of Compact ECR Plasma System (Compact ECR plasma장치의 제작 및 특성 연구)

  • 윤민기;박원일;남기석;이기방
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.4
    • /
    • pp.84-91
    • /
    • 1994
  • A compact electron cyclotron resonance(ECR) plasma system composed of a microwave generator and a magnet coil was fabricated. A Langmuir single probe was used to investigate the plasma characteristics of the system through I-V measurements. The performance of the compact ECR plasma system was tested for the case of silicon etching reaction with $CF_{4}/O_{2}$(30%) mixed gas. Electron density and etch rate increased to maximum values and then decreased with increasing argon gas pressure, but electron temperature changed in the opposite way. The electron density and the electron temperature of argon gas plasma were 0.85${\times}~5.5{\times}10^{10}cm^{-3}$ and 4.5~6.0 eV, respectively, in the pressure range from $3{\times}10^{4}$ to 0.05Torr. The etch rate reached a maximum value at the position of 2.5cm from the bottom of plasma cavity. Etch rate uniformity was $\pm$6% across 6cm wafer. Anisotropic index was 0.75 at 1.5${\times}10^{-4}$Torr.

  • PDF

Room Temperature Fabrication of Silicon Oxide Thin Films by ECR PECVD (ECR PECVD 에 의한 상온 실리콘 산화막 형성)

  • 이호영;전유찬;주승기
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.4
    • /
    • pp.462-467
    • /
    • 1993
  • ECR PECVD(Electron Cyclotron Resonance Plasma Enhanced Chemical Vapor Deposition )장치를 이용하여 (100) 실리콘 기판 위에 실리콘 산화막을 상온에서 증착하였다. 기체 유량비(SiH4/O2)가 막의 성질에 미치는 영향을 고찰하여 최적의 증착 조건을 도출하였다. 기체 유량비가 0.071일 때 비가역 파괴 전장은 9~10MV/cm 이었고, 4~5MV/cmm의 전장하에서 누설 전류는 ~10-11 A/$ extrm{cm}^2$이었다. 이러한 수치들은 액정 표시 소자용 박막 트랜지스터와 같이 저온의 제조공정이 요구되는 소자를 만들기에 충분하다.

  • PDF

Microwave Electric Field and Magnetic Field Simulations of an ECR Plasma Source for Hyperthermal Neutral Beam Generation

  • Lee, Hui-Jae;Kim, Seong-Bong;Yu, Seok-Jae;Jo, Mu-Hyeon;NamGung, Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.501-501
    • /
    • 2012
  • A 2.45 GHz electron cyclotron resonance (ECR) plasma source with a belt magnet assembly configuration (BMC) was developed for hyperthermal neutral beam (HNB) generation. A plasma source for high flux HNB generation should be satisfied with the requirements: low pressure operation, high density, and thin plasma. The ECR plasma source with BMC achieved high density at low operation pressure due to electron confinement enhancement caused by high mirror ratio and drifts in toroidal direction. The 2.45 GHz microwave launcher had a circularly bended WR340 waveguide with slits. The microwave E-field profile induced by the microwave launcher was studied in this paper. The E-field profile was a cups field perpendicular to B-filed at ECR zone. The optimized E-field profile and B-field were found for effective ECR heating.

  • PDF