• 제목/요약/키워드: electromagnetic wave

검색결과 1,619건 처리시간 0.032초

전자파를 이용한 폐쇄배전반내 전력기기의 열화 온라인 진단시스템 개발 (Development of on-line system using electromagnetic wave for diagnosis of deteriorated power equipment in enclosed switchboard)

  • 강창원;최길수;이영상;강대수;김재철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.178-181
    • /
    • 2001
  • This paper presents the development of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise. Power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector, and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

폐쇄 배전반에서의 부분 방전 On-Line 열화 감시 시스템 개발 (Development of electromagnetic wave detecting equipment for diagnosis of partial discharge in enclosed switchboard)

  • 전광호;강창원;김재철;김광화;강대수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.318-320
    • /
    • 2000
  • This paper presents the develop-ment of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

전파무향실용 페라이트 전파흡수체의 설계 (A Design of Ferrite Electromagnetic Wave Absorber for Anechoic Chamber)

  • 이창우;김동일;김하근
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 1998년도 추계종합학술대회
    • /
    • pp.408-413
    • /
    • 1998
  • Electromagnetic wave absorbers for anechoic chamber are needed to broaden the useful frequency bandwidth, reduce the thickness, and decrease the weight. There are various absorbers proposed for the above conditions, but they could not decisively solve it the alone requirements. The Electromagnetic wave absorber made by a conventional ferrite tile has, for example, broadened the useful frequency bandwidth by the way of forming air layer(practically use urethane foam, etc.) on the ferrite tile. Therefore, an air layer is formed between a reflection plate and a sintered Ni-Zn ferrite tile of 7 mm in thickness, which has reflectivity less than -20 dB from 30 MHz to 600 MHz in bandwidth. Accordingly, in this paper, a broadened electromagnetic wave absorber will be designed, which has the reflection characteristics less than -20 dB from 30 MHz to 6000 MHz in the bandwidth. Then we will design a super broadband electromagnetic wave absorber by inserting square Ferrite Cylinders Type with the thickness less than 11 m and with the frequency band from 30 MHz to 6000 MHz under the above tolerance limits. The purpose of this research is on the development of a universal anechoic chamber for measuring radiated electromagnetic wave or immunity of electronic equipments, GTEM-cell, wall material for prevention TV ghost, etc.

  • PDF

전파무향실용 페라이트 전파흡수체의 설계 (Design of Ferrite Electromagnetic Wave Absorber for Anechoic Chamber)

  • 김동일;이창우;김하근;전상엽;정세모
    • 한국정보통신학회논문지
    • /
    • 제3권1호
    • /
    • pp.43-50
    • /
    • 1999
  • Electromagnetic wave absorbers for anechoic chamber are needed to broaden the useful frequency bandwidth, reduce the thickness, and decrease the weight. There are various absorbers proposed for the above conditions, but they could not decisively solve the above requirements. The Electromagnetic wave absorber made by a conventional ferrite tile has, for example, broadened the useful frequency bandwidth by the way of forming air layer. Therefore, an air layer is formed absorber between a reflection plate and a sintered Ni-Zn ferrite tile of 7 mm in thickness, which has reflectivity less than -20 dB from 30 MHz to 450 MHz in frequency band, far narrower than the aimed bandwidth. The purpose of this paper is on the development of a universal anechoic chamber for measuring radiated electromagnetic wave or immunity of electronic equipments, GTEM-cell, wall material for prevention of TV ghost, etc. Accordingly, in this paper, a broadened electromagnetic wave absorber is designed, which has the reflection characteristics less than -20 dB from 30 MHz to 5,430 or 8,000 MHz in the bandwidth. Then we will design a super broadband electromagnetic wave absorber by inserting square Ferrite Cylinders Type with the thickness less than 23.5 m in three-layed type and with the frequency band from 30 MHz to 5,430-8,000 MHz under the above tolerance limits.

  • PDF

십자형 슬롯을 가지는 적층형 초광대역 페라이트 전파흡수체의 설계 (Design of Super Wide-Band Electromagnetic Wave Absorbers Using Cross-Slotted Ferrite in the Double-Layered Type)

  • 김동일;전상엽
    • 한국전자파학회논문지
    • /
    • 제7권4호
    • /
    • pp.346-352
    • /
    • 1996
  • 초광대역 주파수 특성을 가지며, 제2층에 십자형 슬롯을 가지는 2층형 전파흡수체의 광대역 설계법을 제안하였다 이와같은 광대역 전파흡수체는 등가재료정수법을 적용한 이론 모델을 이용하여 설계할 수 있다. 제안한 모델을 바탕으로 30MHz~3,170MHz의 주파수 범위에서 우수한 반사감쇠 특성을 가지는 초광대역 전파흡수체를 설계하였다.

  • PDF

산업설비의 전자파 장해환경 분석 (Analysis of Electromagnetic Wave Interference Environment to Industrial Machinery)

  • 홍용규;김태현;김덕근;임장섭;문채주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1835-1837
    • /
    • 2001
  • The interference of electromagnetic waves in factory is increasing according with development of industrial society and many use of electrical machinery. Electromagnetic wave is defined as the electrical and magnetic field formed by electrical and electronic equipment used in daily lives, which indiscriminatingly affects the human health and operation of machinery. The electromagnetic spectrum ranges from the shorter wavelengths(including gamma and x-rays) to the longer wavelengths(including microwaves and broadcast radio waves). Radiation that is not absorbed or scattered in the atmosphere can reach and affect on the operation of machine. In this study, electromagnetic wave that is interfered to the machine and human is detected in factory, and decrease method of electromagnetic wave interference is studied.

  • PDF

Preparation and Electromagnetic Properties of an Electromagnetic Wave Absorber

  • Sun, Chang;Sun, Kangning;Pang, Laixue;Liu, Jian
    • Journal of Magnetics
    • /
    • 제21권1호
    • /
    • pp.61-64
    • /
    • 2016
  • In this study, we report the as-prepared MgO-doped $BaFe_{12}O_{19}$, which was prepared by calcination technique and high-energy ball milling process, as an electromagnetic wave absorber. The phase analysis of $BaFe_{12}O_{19}$ and the as-prepared MgO-doped $BaFe_{12}O_{19}$ was detected utilizing X-ray Diffractometer (XRD). The microstructure was characterized using Scanning Electron Microscope (SEM). By means of the transmission/reflection coaxial line method, the electromagnetic properties and microwave absorbing properties of the as-prepared electromagnetic wave absorber were studied. It is found that the electromagnetic wave absorber has a minimum reflection loss value of -41 dB at 4.27 GHz with a matching thickness of 2.6 mm. The experiment results revealed that the as-prepared electromagnetic wave absorber could find potential applications in many military as well as commercial industries.

A Study on Fabrication and Evaluation of Ferrite Electromagnetic Wave Absorber

  • Kim, Dong-Il;Bae, Jae-Young;Son, June-Young;Won, Young-Soo;Song, Jae-Man
    • Journal of electromagnetic engineering and science
    • /
    • 제1권1호
    • /
    • pp.95-99
    • /
    • 2001
  • According to the progress of the electronic industy and radio communication technologies, mankind might enjoy its abundant life On the other hand, many social problems such as EMI, and unnecessary electromagnetic wave occur due to the increased use of electromagnetic wave. Therefore, the organiztions such as CISPR, FCC, ANSl,etc. have provided the standard of electromagnetic wave enviroment for the countermeasure of the EMC. It had been required that the absorbing ability of an electromagnetic wave absorber is more than 20 dB, the bandwidth of which is required through 30 MHz to 1,000 MHz for satisfying the international standard about an anechoic chamber for EMI/EMS measurment. From November of 1998, however, the CISPRll has accepted the extended frequency band from 1 GHz to 18 GHz additionally in the bandwidth of EMI measurementent$^{[1]}$ . In this paper, we proposed a new type absorber satisfying the above requirements and carried out broadband design using the equivalent material constants method. Futheremore, the experiments were carried out over the frequency band from 30 MHz to 2 GHz, and hence, the validity of the proposed design theory was confirmed.

  • PDF

Advanced electromagnetic wave-based method for characterizing defects in cement-based structures using time domain reflectometry

  • Dongsoo Lee;Jong-Sub Lee;Young K. Ju;Yong-Hoon Byun
    • Computers and Concrete
    • /
    • 제33권5호
    • /
    • pp.621-630
    • /
    • 2024
  • This study presents novel electromagnetic wave-based methods for evaluating the integrity of cement-based structures using time domain reflectometry (TDR). Two cement-based plates with embedded rebars are prepared under sound and defective conditions. TDR tests are carried out using transmission lines with various numbers of artificial joints, and electromagnetic waves are measured to assess the integrity of the plates. The experimental results show that the travel time of electromagnetic waves is consistently longer in sound plates than in defective ones, and an increase in the reflection coefficients is observed in the defect zone of the defective plates. Electromagnetic wave velocities are higher in the defective plates, especially when connectors are present in the transmission line. A novel approach based on the area of the reflection coefficient provides larger areas in the defective plates, and the attenuation effect of the electromagnetic waves induces a difference in the areas of the reflection coefficient between the two defect conditions. An alternative method using the centroid of the defect zone slightly overestimates the location of the defect zone. The length of the defect zone is estimated using the defect ratio and wave velocities of cement, air, and plate. The length of the defect zone can also be calculated using the travel times within the plate, total measured length of the plate, and wave velocities in the cement and air. Therefore, the electromagnetic wave-based methods proposed in this study may be useful for estimating the location and length of defect zones by considering attenuation effects.

Coating Effects on Electromagnetic Wave Absorbers Prepared with Mn-Zn Ferrites

  • Song Jae-Man;Kim Dong-Il;Che Seung-Hun;Choi Yun-Seok;Kim Ki-Man;Rhyu Keel-Soo
    • Journal of electromagnetic engineering and science
    • /
    • 제5권4호
    • /
    • pp.161-165
    • /
    • 2005
  • We prepared Mn-Zn ferrite Electromagnetic(EM) wave absorbers. The Mn-Zn ferrite EM wave absorbers were coated with Sr ferrite powders and $Al(OH)_3$ powders. The coated Mn-Zn ferrite EM wave absorbers show improved absorption compared with non-coated Mn-Zn EM wave absorbers.