• Title/Summary/Keyword: electromagnetic susceptibility (EMS)

Search Result 22, Processing Time 0.025 seconds

Electromagnetic Susceptibility Analysis of Phase Noise in VCOs (위상 잡음 이론을 적용한 전압 제어 발진기의 전자파 내성 분석)

  • Hwang, Jisoo;Kim, SoYoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.5
    • /
    • pp.492-498
    • /
    • 2015
  • As the integration of circuit components increases steadily, various EMS(Electromagnetic Susceptibility) problems have emerged from integrated circuits and electrical systems. The electromagnetic susceptibility of VCOs(Voltage Controlled Oscillator) is especially critical in RF systems. Therefore, in this paper, through the phase noise theory that models electrical oscillators as linear time variant systems, the EMS characteristics of representative VCO -ring VCO and LC VCO- with 1.2 GHz of reference oscillating frequency are analyzed under the existence of the electromagnetic noise coupled in power supply. An simulation algorithm is developed to extract impulse response function based on the phase noise theory. When there is no supply noise, the magnitude of the jitter of two oscillators were similar to around 2.1 ps, but in presence of supply noise, the jitter was significantly lower in LC VCOs than ring VCOs.

Study on Methods of Missile Electromagnetic Susceptibility (EMS) Test (유도탄 전자기 내성 시험에 대한 고찰)

  • Lee, Dae-Hyun;Oh, TaeckKeun;Oh, Se-kwon;Kim, Hyung-Jae;Park, Dong-Hyun
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.5
    • /
    • pp.423-429
    • /
    • 2020
  • In this paper, the electromagnetic compatibility (EMC) test standard is described, and the purpose and test configuration for the electromagnetic susceptibility (EMS) test of the missile component and the missile system are confirmed. The test configuration and specifications are suggested by the configuration of the missile component and the missile system based on the US military standards MIL-STD-461F and MIL-STD-464C, and explained that the ungrounded state, the final operating state of the missile component and the missile system, was constructed. In addition, the methods for checking the steady state and the points to be considered during the immunity test were introduced.

Electromagnetic Susceptibility Analysis of I/O Buffers Using the Bulk Current Injection Method

  • Kwak, SangKeun;Nah, Wansoo;Kim, SoYoung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.2
    • /
    • pp.114-126
    • /
    • 2013
  • In this paper, we present a set of methodologies to model the electromagnetic susceptibility (EMS) testing of I/O buffers for mobile system memory based on the bulk current injection (BCI) method. An efficient equivalent circuit model is developed for the current injection probe, line impedance stabilization network (LISN), printed circuit board (PCB), and package. The simulation results show good correlation with the measurements and thus, the work presented here will enable electromagnetic susceptibility analysis at the integrated circuit (IC) design stage.

Proposing a low-frequency radiated magnetic field susceptibility (RS101) test exemption criterion for NPPs

  • Min, Moon-Gi;Lee, Jae-Ki;Lee, Kwang-Hyun;Lee, Dongil
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.1032-1036
    • /
    • 2019
  • When the equipment which is related to safety or important to power production is installed in nuclear power plant units (NPPs), verification of equipment Electromagnetic Susceptibility (EMS) must be performed. The low-frequency radiated magnetic field susceptibility (RS101) test is one of the EMS tests specified in U.S NRC (Nuclear Regulatory Commission) Regulatory Guide (RG) 1.180 revision 1. The RS101 test verifies the ability of equipment installed in close proximity to sources of large radiated magnetic fields to withstand them. However, RG 1.180 revision 1 allows for an exemption of the low-frequency radiated magnetic susceptibility (RS101) test if the safety-related equipment will not be installed in areas with strong sources of magnetic fields. There is no specific exemption criterion in RG 1.180 revision 1. EPRI TR-102323 revision 4 specifically provides a guide that the low-frequency radiated magnetic field susceptibility (RS101) test can be conservatively exempted for equipment installed at least 1 m away from the sources of large magnetic fields (>300 A/m). But there is no exemption criterion for equipment installed within 1 m of the sources of smaller magnetic fields (<300 A/m). Since some types of equipment radiating magnetic flux are often installed near safety related equipment in an electrical equipment room (EER) and main control room (MCR), the RS101 test exemption criterion needs to be reasonably defined for the cases of installation within 1 m. There is also insufficient data regarding the strength of magnetic fields that can be used in NPPs. In order to ensure confidence in the RS101 test exemption criterion, we measured the strength of low-frequency radiated magnetic fields by distance. This study is expected to provide an insight into the RS101 test exemption criterion that meets the RG 1.180 revision 1. It also provides a margin analysis that can be used to mitigate the influence of low-frequency radiated magnetic field sources in NPPs.

Design Technology of the Wideband Power Amplifier for Electromagnetic Susceptibility Measurement (EMS 측정용 광대역 전력 증폭기 설계기술에 관한 연구)

  • 조광윤;류근관;홍의석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.8B
    • /
    • pp.1464-1471
    • /
    • 1999
  • A wide-band high power amplifier to use for radiated electromagnetic field immunity testing of EMS(Electromagnetic Susceptibility) standards has to meet IEC1000-4-3 specification in the frequency bandwidth of 80MHz to 1000MHz. The power amplifier to be described in this paper consists of driving and power stages with wide-band matched circuits by estimated impedances. The mismatching protection circuit is inserted in it to prevent from damage of power device when the output port of power amplifier is opened or shorted by user's mistake. The characteristics of the power amplifier are obtained output power over 100watts, gain over 40dB and flatness of $\pm$0.3dB in the frequency range of 80 ~300MHz. The harmonics suppression characteristics is measured over 20dBc. This wide-band high power amplifier can be useful fur radiated electromagnetic field immunity testing of IEC 1000-4-3 standard.

  • PDF

Immunity Test for Semiconductor Integrated Circuits Considering Power Transfer Efficiency of the Bulk Current Injection Method

  • Kim, NaHyun;Nah, Wansoo;Kim, SoYoung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.2
    • /
    • pp.202-211
    • /
    • 2014
  • The bulk current injection (BCI) and direct power injection (DPI) method have been established as the standards for the electromagnetic susceptibility (EMS) test. Because the BCI test uses a probe to inject magnetically coupled electromagnetic (EM) noise, there is a significant difference between the power supplied by the radio frequency (RF) generator and that transferred to the integrated circuit (IC). Thus, the immunity estimated by the forward power cannot show the susceptibility of the IC itself. This paper derives the real injected power at the failure point of the IC using the power transfer efficiency of the BCI method. We propose and mathematically derive the power transfer efficiency based on equivalent circuit models representing the BCI test setup. The BCI test is performed on I/O buffers with and without decoupling capacitors, and their immunities are evaluated based on the traditional forward power and the real injected power proposed in this work. The real injected power shows the actual noise power level that the IC can tolerate. Using the real injected power as an indicator for the EMS test, we show that the on-chip decoupling capacitor enhances the EM noise immunity.

Development of Leakage Current Sensing Controller in Consideration of Industrial EMS (산업용 EMS를 고려한 누설전류 센싱 컨트롤러의 개발)

  • Park, Sung-Won;Roh, Inh-Bae;Kim, Sang-Dong;Park, Ji-Ho;Kim, Dong-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.70-71
    • /
    • 2009
  • In recent years, a importance of EMS(Electromagnetic Susceptibility) is increased with the spread of a communication device significantly. The compatibility of EMS is evaluated by conduction and radiation of EMI(Electromagnetic Interference). In this paper, a leakage current sensing controller which is considered of industrial EMS is developed. The developed system is consisted of power module, sensing module of leakage current, processer module, display module and communication module. The developed system is evaluated the compatibility of EMS by conduction and radiation of EMI. In evaluation results, the developed system is compatible to the standard of industrial EMS.

  • PDF

릴레이 개폐서지가 프로세서 제어기기에 미치는 전자기적 영향에 관한 연구

  • 안상윤;정재희;민경찬
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.05a
    • /
    • pp.245-250
    • /
    • 1998
  • 각종 전기ㆍ전자기기에서 발생하는 불요 전자파는 노이즈(Noise) 또는 고조파로 불려지고 있는데 이러한 전자파 규제 항목은 크게 두가지(EMI/EMS)로 대분 된다. EMI(Electro magnetic Interference)는 전자파 장해로서 기기 자체에서 발생하는 전자파의 양을 제한하는 것이고 EMS(Electromagnetic Susceptibility)의 경우는 전자파 내성으로서 각종 외부에서 기기 내부로 침입하는 전자기적 에너지에 의하여 기기가 오작동하지 않는 능력을 평가하는 것을 말하며 이 것들을 총칭하여 전자파 적합성(EMC, Electromagnetic Compatibility)라고 정의한다. (중략)

  • PDF

Broad-Band Design of Ferrite One-body EM Wave Absorbers for an Anechoic Chamber

  • Kim, Dong-Il;Son, June-Young;Park, Woo-Keun;Park, Dong-Han
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.2
    • /
    • pp.51-55
    • /
    • 2004
  • With the progress of the electronics industry and radio communication technology, certain problems, such as electromagnetic interference(EMI), have arisen due to the increased use of electromagnetic(EM) waves. International organizations such as CISPR, FCC, and ANSI have provided the standards for the EM wave environment and for the countermeasure of the electromagnetic compatibility(EMC). EM wave absorbers are used for constructing an anechoic chamber to test and measure EMI and electromagnetic susceptibility(EMS). In this paper, we have designed an one-body EM(electromagnetic) wave ferrite absorber, based on the equivalent material constants method for both normally and obliquely incident waves, whose absorption abilities are superior to that of the conventional ones. The fabricated absorber has a thickness of 27.68 mm and shows an absorption ability over 20 ㏈ in the frequency from 30 MHz to 6 ㎓.

A Study on the EMS Analysis of Image Variations for EUT (EUT의 영상변화에 의한 EMS 해석에 관한 연구)

  • Yun, Ki-Bang;Lee, Chang-Bok;Jung, Ki-Beom;Kim, Ki-Doo
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.2
    • /
    • pp.76-83
    • /
    • 2002
  • In this paper, we developed the real-time automation program for the immunity test according to the determination of the EUT image, and analyzed the image of standard PC monitor and the monitor image affected by the electromagnetic field. The image change detection algorithm was realized for the real-time determination of the malfunction, and we attempted to obtain the consistent results for the electromagnetic immunity measurement. We showed the possibility to determine the immunity of the PC monitor and other equipment by performing the image change detection of EUT, and the experimental results for the EUT immunity determination of EMS (Electro-Magnetic Susceptibility, IEC 61000-4-3) are also proposed in line with the international standard and domestic trends.