Simultaneous measurement of velocity and temperature fields in micro-scale flow and its application to electrokinetic flow (마이크로 스케일 유동에서의 속도장 온도장 동시 측정 기법과 동전기 유동에의 적용)

  • Lee, Beom-Joon;Jin, Song-Wan;Kim, Young-Won;Yoo, Jung-Yul
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2585-2590
    • /
    • 2007
  • In this paper, a technique of simultaneously measuring the velocity and the temperature in micro-scale flow is proposed. This method uses particle tracking velocimetry (PTV) for measuring the velocity and laser induced fluorescence (LIF) for measuring the temperature. To measure the accurate velocity and temperature, images for PTV and for LIF are separated by using two light sources and a shutter which is synchronized with a camera. By using only one camera, measurement system can be simplified and the error from complicate optical system can be minimized. Error analyses regarding the concentrations of fluorescent dye and particle and the light source fluctuation are also conducted. It is found that the error of the temperature and the velocity highly depends on the concentration of fluorescent particles which are used for PTV. This technique is applied to the simultaneous measurement of the velocity and the temperature in the electrokinetic flow. It is found that the velocity and temperature vary with the electric field strength and the concentration of electrolyte.

  • PDF

Simultaneous Measurement of Velocity and Temperature Fields in Micro-Scale Flow and Its Application to Electrokinetic Flow (마이크로 스케일 유동에서의 속도장 온도장 동시 측정 기법과 동전기 유동에의 적용)

  • Lee, Beom-Joon;Jin, Song-Wan;Kim, Young-Won;Yoo, Jung-Yul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.7 s.262
    • /
    • pp.644-652
    • /
    • 2007
  • In this paper, a technique of simultaneously measuring the velocity and the temperature in micro-scale flow is proposed. This method uses particle tracking velocimetry (PTV) for measuring the velocity and laser induced fluorescence (LIE) for measuring the temperature. To measure the accurate velocity and temperature, images for PTV and for LIE are separated by using two light sources and a shutter which is synchronized with a camera. By using only one camera, measurement system can be simplified and the error from complicate optical system can be minimized. Error analyses regarding the concentrations of fluorescent dye and particle and the light source fluctuation are also conducted. It is found that the error of the temperature and the velocity highly depends on the concentration of fluorescent particles which are used for PTV. This technique is applied to the simultaneous measurement of the velocity and the temperature in the electrokinetic flow. It is found that the velocity and temperature vary with the electric field strength and the concentration of electrolyte.

Electroosmotic Flows in Microfluidic Chips

  • Yang R.-J.;Fu L.-M.;Lee G.-B.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.123-125
    • /
    • 2003
  • Understanding the physics of electroosmotic flow is important to the optimum design and operation of microfluidic systems. Recent development on the topic in our group is summarized in this presentation. Applications to the variable-volume-Injection, micro flow switch, electrokinetic focusing, and flow cytometer will be presented with our novel design and control.

  • PDF

Semi-pilot Study of Electrokinetic Process for Phenanthrene Removal from Kaolinite

  • Lee, You-Jin;Park, Ji-Yeon;Kim, Sang-Joon;Lee, Young-Cheol;Yang, Ji-Won
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.215-218
    • /
    • 2004
  • The electrokinetically enhanced soil flushing had a great potential to improve the removal efficiency of polycyclic aromatic hydrocarbons (PAHs) from low permeable soils. A semi-pilot study of surfactant-enhanced electrokinetic process was investigated for the removal of phenanthrene from kaolinite. A nonionic surfactant, Tergitol 15-S-12 at 10 g/L was introduced as a flushing agent and 0.001M of sodium chloride was used as an electrolyte. When the constant voltage of 100 V was applied to the system for 25 days, only 0.66 kWh of electric power was consumed and the amount of electroosmotic flow was 6.9 L. The removal efficiency of phenanthrene was about 40 % and it can be improved by increasing the ion concentration of the flushing solution or the applied voltage.

  • PDF

Development and Validation of Numerical Program for Predicting Electrokinetic and Dielectrophoretic Phenomena in a Microchannel (미소채널 내 전기역학 및 유전영동 현상 해석을 위한 수치 프로그램 개발 및 검증)

  • Kwon, Jae-Sung;Maeng, Joo-Sung;Song, Simon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.4
    • /
    • pp.320-329
    • /
    • 2007
  • Electrokinesis and dielectrophoresis are important transport phenomena produced by external electric field applied to a microchannel containing a conductive fluid. We developed a CFD code to predict electrokinetic and dielectrophoretic flows in a microchannel with a uniform circular post array. Using the code, we calculated particle velocities driven by electrokinesis and dielectrophoresis, and conducted Monte Carlo simulations to visualize the particle motions. The code was validated by comparing the results with those from previous studies in literature. At a low electric field, electrokinesis and diffusion is the dominant transport mechanism. At a moderate electric field, dielectrophoresis is balanced with electrokinesis and diffusion, resulting in flowing filaments of particles in the microchannels. However, dielectrophoresis overwhelms the flow at a high electric field and traps particles locally. These results provide useful insight for optimizing design parameters of a microfluidic chip for biochemical analysis, especially for development of on-chip sample pretreatment techniques using electrokinetic and dielectrophoretic effects.

Electrokinetic-Fenton Process for Removal of Phenanthrene (동전기-펜턴 공정을 이용한 phenanthrene 오염토양의 정화)

  • 양지원;박지연;김상준;이유진;기대정
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.1
    • /
    • pp.47-53
    • /
    • 2004
  • Feasibility of electrokinetic process combined with Fenton-like reaction was investigated for the removal of phenanthrene from contaminated soil. Transport of hydrogen peroxide by electroosmosis and decomposition of phenanthrene by Fenton-like reaction were observed in a model system. Electrical potential gradient and electroosmotic flow (EOF) at 10 mA were higher than those at 5 mA. High accumulated EOF resulted in high removal efficiency of phenanthrene because the large amount of hydrogen peroxide was transfered through the soil. Removal efficiency of phenanthrene by water washing was 8.5% for 7 days. The highest removal efficiency including phenanthrene decomposition was 95.6% for 14 days. After the operation, soil samples with removal efficiency of 95.6% showed low concentrations of phenanthrene and its intermediates. From this result, it was presumed that phenanthrene was decomposed to small molecules or mineralized to water and carbon dioxide due to continuous supply of hydrogen peroxide by electroosmotic flow.

Effects of Electric Current and Potential on the Electrokinetic Removal of Heavy Metals from an Abandoned Mine Tailings

  • Shin, Hyun-Moo;Lee, Chang-Eun
    • Journal of Environmental Science International
    • /
    • v.13 no.2
    • /
    • pp.149-159
    • /
    • 2004
  • In the removal of heavy metals from the mine deposit using electrokinetic processes, the effects of operation under both constant current and constant potential conditions were estimated. The results of soil pH distributions for DDW-20 V and DDW-100 mA cases after the electrokinetic remediation tests were observed. In the former case, soil pH was not much changed and kept to almost constant value just little higher than initial soil pH of 3.52, except near the cathode, which was about pH 5. While in the latter case, soil pHs of anode and the cathode regions were less than pH 3 and about 6, respectively. The electroosmotic flow to the cathode increased rapidly till 10 hrs and decreased steadily and then maintained to constant rate until the end of operation at constant current condition. Electric potential gradient was continuously increased to as much as 34.375 V/cm. At the steady state, values of the apparent electric conductivity for DDW-20 V and DDW-100 mA were around 40 ${\mu}\textrm{s}$/cm and 30 ${\mu}\textrm{s}$/cm, respectively. In the DDW-100mA test, Cu, Cd, and Zn except Pb showed the tendency of moving toward the cathode. While in the DDW-20 V case, it was observed that Cu, Zn, and Pb except Cd were not moved to any directions. The results of the tests demonstrated that the electrokinetic soil remediation process could be operated better under constant current condition than constant electric potential condition.

산업단지내 독성유기화합물 및 중금속으로 오염된 토양의 정화복원기술 상용화 연구

  • 김수곤;손규동;박지연;최희철;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.31-34
    • /
    • 2004
  • Feasibility of electrokinetic(EK)-Fenton process and Ozone chemical oxidation were investigated for tile removal of organic contaminants and heavy metals from the contaminated soil. In EK-Fenton process, accumulated electroosmotic flow(EOF) was 80 L for 26 days. Removal efficiency of TPH, As, and Ni were 61%, 36%, and 47%, respectively. The concentration of As was high near the anode due to the transport of anionic As toward the anode, while the concentration of Ni was high near the cathode by the movement of cationic Ni to the cathode. Field scale application of in-situ ozonation was carried out for removal of TPH in 3-D test cell (3 m$\times$2 m$\times$2 m). After 25 days of ozone injection, more than 80% of removal rate was observed through the test cell.

  • PDF

3차원 토양 실험장치에서 동전기-펜턴 공정의 전기삼투흐름 모사

  • 박지연;김상준;이유진;기대정;양지원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.158-161
    • /
    • 2003
  • Removal of phenanthrene by electrokinetic method combined with Fenton-like process was studied in a model system. The scale of reactor was 100cm in length, 100cm in width, and 70cm in height. The distance between electrodes was 70cm. Indonesia kaoline was selected as a model soil. When constant voltage of 100 V was applied to this system, current decreased from 200 mA to 100 mA for 14 days. Total accumulated EOF was about 55,000 mL. The concentration of phenanthrene near anode was very low because direction of electroosmosis was from anode to cathode and hydrogen peroxide was supplied to anode reservoir. Phenanthrene concentration was increased as the location was far from anode because hydrogen peroxide was gradually decomposed and then the rate of hydroxyl radical production was decreased.

  • PDF

전압일정과 전류일정 조건에서의 동전기 정화 현상에 관한 해석

  • 김병일;김기년;이호진;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.203-206
    • /
    • 2004
  • To analysis the electrokinetic phenomena in the ground dependent on the way of applied electric power, such as constant current and constant voltage, the governing equations are derived considering advection, diffusion, ionmigration, and then they were formulated using by finite difference method. The developed program is verified by comparing the tested and predicted results reported in present papers. The results indicate that the slightly small electrical potential is predicted for constant current and for constant voltage pH near to the cathode was small than the test results. But the other predictions including the final suction, pH of electrolyte and cumulative flow are similar to the test results and predictions.

  • PDF