• Title/Summary/Keyword: electrodermal activity

Search Result 56, Processing Time 0.033 seconds

Development of the Electrodermal Activity Monitoring System for the Evaluation of Train Driver's Arousal State (기관사의 각성상태 평가를 위한 소형 피부전기활성도 측정 시스템 개발)

  • Lim, Min-Gyu;Lee, Young-Jae;Lee, Kang-Hwi;Kang, Seung-Jin;Kim, Kyeung-Nam;Park, Hee-Jung;Yang, Heui-Kyung;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.9
    • /
    • pp.1286-1293
    • /
    • 2014
  • Typically, studies through the simulation system have been progressed, because the evaluation of the driver's arousal state about the service of a actual train has risk of safety for the driver. When configured event same as the real in simulation system, the ability to cope with an accident situation may be the same each other. But the difference in the state of tension or arousal will occur. In this study, requested to cooperate with the railways in order to escape from these constraints, and the target of the experiment was to real engineer service. I was set about experiment when the train was stopped as safe as possible. As a result, the beta wave of EEG signals that representing complex calculations or anxiety is increased rapidly on the basis of a flag station from at the time of departure. The size of the electrodermal activity signal in response to movement of the body gave a noticeable. In terms of HRV, if the train approach a flag station gradually and the R-R interval is narrowed. So that the driver can be estimated as arousal state. In accordance with this study, if the quantitative standard of arousal state be based on the driver's biosignals will provide, it will be able to take advantage of development the system that would prevent train accidents caused by human error.

Reliability and responsiveness of Equivital Lifemonitor and photoplethysmography based wristwatch for the assessment of physiological parameters during a simulated fatigue task

  • Anwer, Shahnawaz;Li, Heng;Umer, Waleed;Antwi-Afari, Maxwell Fordjour;Wong, Arnold YL
    • International conference on construction engineering and project management
    • /
    • 2020.12a
    • /
    • pp.257-264
    • /
    • 2020
  • Objective: To investigate test-retest reliability and responsiveness of Equivital Lifemonitor and photoplethysmography based wristwatch tools in assessing physiological parameters during a simulated fatigue task. Methods: Ten university students (Mean age, 30.6 ± 1.7 years) participated in this pilot study. Participants were asked to perform a 30-minute of a simulated fatigue task in an experimental setup in a lab. The physiological parameters (e.g., heart rate, heart rate variability, respiratory rate, electrodermal activity, and skin temperature) were measured at baseline and immediately after the fatigue task. An intraclass correlation coefficient (ICC2,1) was used to evaluate the test-retest reliability of each tool in assessing physiological measures. In addition, the responsiveness of each tool to measure changes from baseline to posttest was calculated using a standardized response mean. Results: The Equivital Lifemonitor has shown good to excellent test-retest reliability for the assessment of heart rate (ICC, 0.97), heart rate variability (ICC, 0.86), respiratory rate (ICC, 0.77), and local skin temperature (ICC, 0.76). However, photoplethysmography based wristwatch showed moderate to good test-retest reliability for the assessment of heart rate (ICC, 0.71), heart rate variability (ICC, 0.73), electrodermal activity (ICC, 0.80), and skin temperature (ICC, 0.72). A large standardized response mean (>0.8) indicates that both tools can capture the changes in heart rate, heart rate variability, respiratory rate, skin temperature, and electrodermal activity after a 30-minute of fatigue task. Conclusions: The Equivital Lifemonitor and photoplethysmography based wristwatch devices are reliable in measuring physiological parameters after the fatigue task. Additionally, both devices can capture the fatigue response after a simulated construction task. Future field studies with a larger sample should investigate the sensitivity and validity of these tools in measuring physiological parameters for fatigue assessment at construction sites.

  • PDF

Emotional and autonomic responses to IAPS-based stimulation : Effects of 1/f music and white noise on electrodermal and cardiorespiratory variables during the post-stress recovery (국제정서사진체계 ( IAPS ) 를 이용한 정서 및 자율신경계 반응 연구 : 1/f 음악 및 white noise가 스트레스 회복단계에서의 피부전기반응 및 심박호흡계 반응에 미치는 영향)

  • ;Estate Sokhadze
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1997.11a
    • /
    • pp.228-232
    • /
    • 1997
  • The special interest should be paid to the analysis of the influences of positive emotions in terms of their possible effects on the dyanmics of autonomic. recovery after the negative affective stimualtion. Taking into account emotion-specific autonomic response patterning and dissociation of parameters of autonomic arousal during experience of both positive and negative emotional states, this problem seems a challenging one. In present study several autonomic parameters were analyzed altogether, namely inedices of electrodermal activity, heart rate and respitation rate during consecutive combination or both IAPS-based visual affective and auditory stimulation. The aim of the study was analysis of patterns of electrodermal and cardiorespiratory responses during emotional states evoked by negative affective visual stimulation followed by positive or neutral auditory one with intention to identify if the latter is able to facilitate post-stress recovery and enhance restoration of pre-arousal levels. The main orientation was dirdcted towards the further application of experimentally induced comfort emotions for dampening the negative consequences of exposure to stressful stimuli.

  • PDF

Auditory Evoked Skin Potential in Normal Subjects (정상 성인에서 청성유발 피부전위)

  • Heo, Seung-Deok;Jung, Dong-Keun;Suh, Duk-Joon;Kim, Gwang-Nyeon;Kim, Gi-Ryon;Kang, Myung-Koo;Kim, Lee-Suk
    • Speech Sciences
    • /
    • v.12 no.2
    • /
    • pp.81-88
    • /
    • 2005
  • Electrodermal activity(EDA) is a bio-electric signal which occurs at the skin surface during the sweating. EDA reflects the activity of the sympathetic axis of the autonomic nervous system. EDA is associated with the eccrine sweat gland at the palmar and plamar surface. This study was aimed to characterize the relationship between EDA and auditory stimulus intensities. Acoustic stimulus used in this study were 500 Hz, 1 kHz, 2 kHz of narrow band noise, which were representative of speech frequencies in audible range. Stimulus intensity between 90 and 30 dB in 10 dB within dynamic range. After deriving the minimum stimulus intensity(threshold of skin potential) which elicited skin potential, and then the latency and amplitude were derived from waveform of skin potential, each latency and amplitude were compared to stimulus intensity. The waveform of skin potential were recorded stably, and the threshold of skin potential appeared nearly the hearing threshold level of the participant. The latency was decreased and the amplitude was increased according to the increase of the stimulus intensity. These results suggest that auditory evoked skin potential can be applicable to auditory assessment and audiological diagnosis tool.

  • PDF

Basic Emotions Elicited by Korean Affective Picture System Can be Differentiated by Autonomic Responses

  • Sohn, Jin-Hun;Estate Sokhadze;Lee, Kyug-Hwa;Imgap Yi
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.04a
    • /
    • pp.370-379
    • /
    • 2000
  • Autonomic responses were analyzed in 323 college students exposed to visual stimulation with Korean Affective Picture System (KAPS). Cardiac, vascular and electrodermal variables were recorded during 30 sec of viewing affective pictures. The same slides intended to elicit basic emotions (fear, anger, surprise, disgust, sadness, happiness) were presented to subjects in 2 trials with different experimental context. The first time slides were shown without any instructions (passive viewing), while during the second with instruction to exert efforts to magnify experienced emotion induced by pictures (active viewing). The aim of the study was to differentiate autonomic manifestations of emotions elicited by KAPS stimulation and to identify the role of instructed emotional engagement on physiological response profiles. The obtained results demonstrated reproducibility of responses in both trials with different contexts. Pairwise comparison of physiological responses in emotion conditions revealed the most pronounced differentiation for "ear-anger" and "fear-sadness" pairs (in electrodermal and HR variability parameters). "Fear-surprise" pair was also well differentiable. The typical response profile for all emotions included HR acceleration (except happiness and surprise), an increase of electrodermal activity, and a decrease of pulse volume. Higher cardiovascular and electrodermal reactivity to fear observed in this study, e.g., as compared to data with IAPS as stimuli, can be explained by cultural relevance and higher effectiveness of KAPS as stimuli, can be explained by cultural relevance and higher effectiveness of KAPS in producing certain emotions such as fear in Koreans.

  • PDF

Exploratory Study on Sympathetic Skin Response to Physical and Psychological Stimulation (신체적 자극과 심리적 자극에서 교감신경피부반응에 대한 탐색연구)

  • Gi-Ryun Kim;Dong-Keun Jung
    • Journal of Biomedical Engineering Research
    • /
    • v.45 no.1
    • /
    • pp.37-42
    • /
    • 2024
  • In this study, we explored the possibility of using sympathetic skin response (SSR), a type of electrodermal activity (EDA), as a method of evaluating a subject's responsiveness to physical or psychological stimulation. To provide physical and psychological stimulation, walking on an acupressure plate and a roller coaster virtual reality experience wearing an HMD (head mounted display) were used. Walking on an acupressure plate significantly increased the SSR signal compared to walking on the bare floor. Additionally, it was observed that the SSR response significantly increased while the subject was wearing an HMD and experiencing a roller coaster compared to the resting state of sitting on a chair. The SSR response to physical or psychological stimulation increased in all subjects, but the degree of reactivity differed. These experimental results suggested that sympathetic skin response (SSR) is a useful tool as a biosignal that can be used to evaluate the human body's responsiveness to physical stimulation or psychological stimulation using virtual reality.

The role background noise intensity on Physiological activity during performance of mental task (인지과제 수행시 배경 소음의 크기에 따른 생리적 반응차)

  • Sohn Jin-Hun;Sokhadze Estate M.;Min Yoon-Ki;Lee Kyung-Hwa;Choi Sangsup
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.269-273
    • /
    • 1999
  • Combination of mental stress task with noise background is a traditional tool employed in psychophysiology. However, intensity of background noise is a factor affecting both performance on test and psychophysiological responses associated with stress evoked by mental load in noisy environment. In the current study on 7 subjects we analyzed the influence of white noise (WN) intensity (55, 70, and 85 dB[A] ) on psychophysiological responses during word recognition test performed on noise background. There were recorded following physiological variables: electrodermal activity (EDA) , namely, skin conductance level (SCL), skin conductance response (SCR) amplitude (SCR-A), rise time and total number of SCRs (N-SCR); cardiovascular activity, e.g., heart rate (HR), respiratory sinus arrhythmia (RSA) index, pulse transit time (PTT), finger pulse volume (PV), skin temperature (SKT) and respiratory activity, such as respiration rate (RESP-R) and inspiration wane amplitude (RESP-A) during baseline resting state and 40 s long performance on 3 similar Korean word recognition tests with different WN intensity (55, 70, and 85 dB). Electrodermal responses (SCR-A, SCL, N-SCR) demonstrated gradual increment with increased intensity of noise, and this increase of response magnitude with higher intensity of noise was typical also for r skin temperature (phasic SKT decrease) and pulse volume (phasic and tonic PV decrease). However, some cardiovascular and respiratory responses did not exhibit same tendency of gradual increase of reactivity , namely HR, as well as RESP-R and RESP-A showed decrement of response magnitudes. Important finding in terms of cardiovascular reactivity was that 55 and 70dB evoked similar profiles, while 85dB WN resulted in significantly different profile of reactions, suggesting that there exists a threshold level after which intensive auditory stimulation elicits psychophyslological responses pattern of different quality. There are discussed potential autonomic mechanism involved in mediation of observed physiological responses.

  • PDF

Inferring Pedestrian Level of Service for Pathways through Electrodermal Activity Monitoring

  • Lee, Heejung;Hwang, Sungjoo
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.1247-1248
    • /
    • 2022
  • Due to rapid urbanization and population growth, it has become crucial to analyze the various volumes and characteristics of pedestrian pathways to understand the capacity and level of service (LOS) for pathways to promote a better walking environment. Different indicators have been developed to measure pedestrian volume. The pedestrian level of service (PLOS), tailored to analyze pedestrian pathways based on the concept of the LOS in transportation in the Highway Capacity Manual, has been widely used. PLOS is a measurement concept used to assess the quality of pedestrian facilities, from grade A (best condition) to grade F (worst condition), based on the flow rate, average speed, occupied space, and other parameters. Since the original PLOS approach has been criticized for producing idealistic results, several modified versions of PLOS have also been developed. One of these modified versions is perceived PLOS, which measures the LOS for pathways by considering pedestrians' awareness levels. However, this method relies on survey-based measurements, making it difficult to continuously deploy the technique to all the pathways. To measure PLOS more quantitatively and continuously, researchers have adopted computer vision technologies to automatically assess pedestrian flows and PLOS from CCTV videos. However, there are drawbacks even with this method because CCTVs cannot be installed everywhere, e.g., in alleyways. Recently, a technique to monitor bio-signals, such as electrodermal activity (EDA), through wearable sensors that can measure physiological responses to external stimuli (e.g., when another pedestrian passes), has gained popularity. It has the potential to continuously measure perceived PLOS. In their previous experiment, the authors of this study found that there were many significant EDA responses in crowded places when other pedestrians acting as external stimuli passed by. Therefore, we hypothesized that the EDA responses would be significantly higher in places where relatively more dynamic objects pass, i.e., in crowded areas with low PLOS levels (e.g., level F). To this end, the authors conducted an experiment to confirm the validity of EDA in inferring the perceived PLOS. The EDA of the subjects was measured and analyzed while watching both the real-world and virtually created videos with different pedestrian volumes in a laboratory environment. The results showed the possibility of inferring the amount of pedestrian volume on the pathways by measuring the physiological reactions of pedestrians. Through further validation, the research outcome is expected to be used for EDA-based continuous measurement of perceived PLOS at the alley level, which will facilitate modifying the existing walking environments, e.g., constructing pathways with appropriate effective width based on pedestrian volume. Future research will examine the validity of the integrated use of EDA and acceleration signals to increase the accuracy of inferring the perceived PLOS by capturing both physiological and behavioral reactions when walking in a crowded area.

  • PDF

AUTONOMIC MECHANISMS OF AN ACUTE STRESS RESPONSE DURING WORD RECOGNITION TASK PERFORMANCE WITH INTENSE NOISE BACKGROUND (백색소음하의 단어재인검사 수행에 따른 자율신경계 스트레스 반응)

  • ;;;Estate Sokhadze
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1999.03a
    • /
    • pp.127-132
    • /
    • 1999
  • Cardiovascular, respiratory and electrodermal responses to acute stress episodes modeled by combined presentation of intense white noise and performance of word recognition task with noise background were studied in 15 college students. Experimental procedure consisted in sessions with white noise, word recognition task presentation with noise background and test with noise background. Recorded physiological variables were analyzed in terms of their sensitivity to detect activation of sympathetic and parasympathetic branches of autonomic nervous system and thus reflect autonomic arousal level during shout-term stress-inducing experimental manipulations. It was shown that performance of effortful mental task with noise background elicited significant physiological responses typical for active coping behavior, namely electrodermal arousal and increased cardiovascular activity. this response profile was more profound as compared to white noise only or attending task in noise background. However, all physiological responses were mostly phasic, without long-term tonic changes, since almost all variables recovered to their initial baseline levels, suggesting that dominant autonomic mechanisms in transient acute stress episodes were of parasympathetic nature (withdrawal in stress with subsequent activation in restoration period), while sympathetic contribution was not long-lasting. Nevertheless, increased number of stressors and their longer exposure may result in higher profile of tonic sympathetic arousal and reduced functional role of vagal mechanisms in autonomic balance regulation.

  • PDF

Portable arousal control system using electrodermal activities (피부 전기활동을 이용한 휴대형 각성도 측정 및 제어 시스템)

  • Ko, Han-Woo;Lee, Woan-Kyu;Kim, Youn-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.55-64
    • /
    • 1996
  • To control arousal level using physiological index, electrodermal activity signal was detected and separated into skin impedance level and response. Arousal state decision and control algorithm was studied to implement and evaluate real time portable arousal control system. The implemented system can detect and control arousal state from initial drowsy state. This system will be applicable to the evaluation of the effect of warning signal, driver's drowsy detecting system, and sleep study.

  • PDF