• 제목/요약/키워드: electrochemical quartz crystal microbalance(EQCM)

검색결과 21건 처리시간 0.026초

Construction of Low Noise Electrochemical Quartz Crystal Microbalance

  • 황의진;임영란
    • Bulletin of the Korean Chemical Society
    • /
    • 제17권1호
    • /
    • pp.39-42
    • /
    • 1996
  • A new oscillator for electrochemical quartz crystal microbalance (EQCM) was developed by using an operational amplifier without any LC component. The home-made EQCM using this oscillator showed only 0.02 Hz frequency noise at 0.3 s gate time when a 6 MHz AT-cut crystal was used. Pb underpotential deposition on gold substrate in nitric acid media was examined to demonstrate the performance of this EQCM. The derivative of frequency change could be obtained without averaging multiple scans.

Electrochemical Reactions of $C_{60}$ Films in the Presence of Water : An Electrochemical Quartz Crystal Microbalance Study

  • 서경자;신명순;전일철
    • Bulletin of the Korean Chemical Society
    • /
    • 제17권9호
    • /
    • pp.781-786
    • /
    • 1996
  • Mass transport behavior of C60 films on electrodes with different thicknesses has been studied by an Electrochemical Quartz Crystal Microbalance (EQCM) during electrochemical reduction-oxidation processes in the presence of water. C60 films were found to be reduced in the presence of water and they remains quite stable. In thin films, the mass on electrode decreased after a complete cycle while X-ray Photoelectron Spectroscopy (XPS) study does not support the existence or formation of C60-epoxides during electrochemical reduction processes in the presence of water or oxygen.

자기조립된 Viologen 단분자막의 모폴로지 관찰과 전하이동 특성 연구 (Study on Morphology Investigation and Electron-Transfer Property of Self-Assembled Viologen Monolayers)

  • 이동윤;박상현;권영수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.395-396
    • /
    • 2005
  • We fabricated self-assembled monolayers(SAMs) onto quartz crystal microbalance(QCM) using viologen, which has been widely used as electron acceptor and electron transfer mediator. We determined the time dependence to resonant frequency shift during self-assembly process and observed the morphology of self-assembled mono layers by STM and investigated the electrochemical behavior of SAMs by cyclic voltammetry. Electrochemical deposition of viologen was investigated using electrochemical quartz crystal microbalance(EQCM). The redox reactions of viologen were highly reversible and the EQCM has been employed to monitor the electrochemically induced adsorption of SAMs during the redox reactions.

  • PDF

Frequency-Distance Responses in SECM-EQCM: A Novel Method for Calibration of the Tip-Sample Distance$\S$

  • 신명선;전일철
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권11호
    • /
    • pp.1227-1232
    • /
    • 1998
  • The frequency response on the tip-sample distance in scanning electrochemical microscopy (SECM) that is combined with an electrochemical quartz crystal microbalance (EQCM) is described. The oscillation frequency of the EQCM increases rapidly when the SECM tip is very close to the substrate electrode surface. This frequency increase is reproducible regardless of the current feedback in SECM, which is attributed to the stress caused by the tip pressing the quartz crystal. It is useful to calibrate the tip-sample distance with respect to the frequency change when a combined system of SECM and EQCM (SECM-EQCM) is used. This method could be applied to several cases such as rigid metal electrode and non-conducting or partially conducting polymer coating prepared on the quartz crystal regardless of the feedback current.

EQCM을 이용한 아이코산티올 단분자막의 전기화학적 탈착 (The electrochemical desorption of an eicosanethiol monolayer by electrochemical quartz crystal microbalance)

  • 정진갑
    • 분석과학
    • /
    • 제8권3호
    • /
    • pp.383-389
    • /
    • 1995
  • A new approach for the measurement of the surface coverages of monomolecular films fabricated by spontaneous adsorption of thiol compounds on gold is described. It is based on the mass change measurement with EQCM for the reductive electrochemical desorption of thiol in aqueous KOH solution. The results were compared with that of charge calculation during electrochemical desorption. The surface coverage value for eicosanethiol agrees with that obtained by charge calculation of electrochemical reduction as well as that expected from a geometrical model of the compact monolayer.

  • PDF

자기조립된 Viologen 단분자막의 표면이미지 관찰과 계면전하이동 특성 연구 (Study on Morphology Investigation and Charge-transfer Property of Self-assembled Viologen Monolayers)

  • 박상현;이동윤;박재철;권영수
    • 한국전기전자재료학회논문지
    • /
    • 제19권3호
    • /
    • pp.246-249
    • /
    • 2006
  • We fabricated self-assembled monolayers(SAMs) onto quartz crystal microbalance(QCM) using viologen, which has been widely used as electron acceptor and electron transfer mediator. We determined the time dependence on resonant frequency shift during self-assembly process and observed the morphology of self-assembled monolayers by STM and investigated the electrochemical behavior of SAMs by cyclic voltammetry. Electrochemical deposition of viologen was investigated using electrochemical quartz crystal microbalance(EQCM). The redox reactions of viologen were highly reversible and the EQCM has been employed to monitor the electrochemically induced adsorption of SAMs during the redok reactions. The total frequency change was about 9.5 Hz, and 7.1 Hz. From the data, we could know the mass change was about 10.16 ng and 7.60 ng, respectively. Finally, the EQCM has been employed to monitor the electrochemically induced adsorption of self-assembled monolayers on Au surfaces.

수정진동자를 이용한 자기조립된 Viologen 유도체의 계면전하이동 특성 (Surface Charge Transfer of Self-Assembled Viologen Derivative Using Quartz Crystal Microbalance)

  • 박상현;류길용;이동윤;권영수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.256-257
    • /
    • 2005
  • We fabricated self-assembled monolayers(SAMs) onto quartz crystal microbalance(QCM) using viologen, which has been widely used as electron acceptor and electron transfer mediator. The viologen derivative exist in three redox states, namely. These redox reactions are highly reversible and can be cycled many times without significant side reactions, respectively. We studied the characteristics of charge transfer using different electrolyte solutions by electrochemical quartz crystal microbalance (EQCM). From the data, the redox peak currents were nearly equal charges during redox reaction and existed to an excellent linear interrelation between the scan rates and first redox peak currents. The redox reactions of viologen were highly reversible and the EQCM has been employed to monitor the electrochemically induced adsorption of SAMs during the redox reactions.

  • PDF

Characterization of Surface Films Formed Prior to Bulk Reduction of Lithium in Rigorously Dried Propylene Carbonate Solutions

  • 창석균;이효중;강헌;박수문
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권5호
    • /
    • pp.481-487
    • /
    • 2001
  • Surface films formed prior to bulk reduction of lithium have been studied at gold, platinum, and copper electrodes in rigorously dried propylene carbonate solutions using electrochemical quartz crystal microbalance (EQCM) and secondary ion mass spectrometry experiments. The results indicate that the passive film formation takes place at a potential as positive as about 2.0 V vs. Li/Li+ , and the passive film thus formed in this potential region is thicker than a monolayer. Quantitative analysis of the EQCM results indicates that electrogenerated lithium reacts with solvent molecules to produce a passive film consisting of lithium carbonate and other compounds of larger molecular weights. The presence of lithium carbonate is verified by SIMS, whereas the lithium compounds of low molecular weights, including lithium hydroxide and oxide, are not detected. Further lithium reduction takes place underneath the passive film at potentials lower than 1.2 V with a voltammetric current peak at about 0.6 V.

Imprinted Graphene-Starch Nanocomposite Matrix-Anchored EQCM Platform for Highly Selective Sensing of Epinephrine

  • Srivastava, Juhi;Kushwaha, Archana;Singh, Meenakshi
    • Nano
    • /
    • 제13권11호
    • /
    • pp.1850131.1-1850131.19
    • /
    • 2018
  • In this paper, an electrochemical sensor for epinephrine (EP), a neurotransmitter was developed by anchoring molecularly imprinted polymeric matrix (MIP) on the surface of gold-coated quartz crystal electrode of electrochemical quartz crystal microbalance (EQCM) using starch nanoparticles (Starch NP) - reduced graphene oxide (RGO) nanocomposite as polymeric format for the first time. Use of EP in therapeutic treatment requires proper dose and route of administration. Proper follow-up of neurological disorders and timely diagnosis of them has been found to depend on EP level. The MIP sensor was developed by electrodeposition of starch NP-RGO composite on EQCM electrode in presence of template EP. As the imprinted sites are located on the surface, high specific surface area enables good accessibility and high binding affinity to template molecule. Differential pulse voltammetry (DPV) and piezoelectrogravimmetry were used for monitoring binding/release, rebinding of template to imprinted cavities. MIP-coated EQCM electrode were characterized by contact angle measurements, AFM images, piezoelectric responses including viscoelasticity of imprinted films, and other voltammetric measurements including direct (DPV) and indirect (using a redox probe) measurements. Selectivity was assessed by imprinting factor (IF) as high as 3.26 (DPV) and 3.88 (EQCM). Sensor was rigorously checked for selectivity in presence of other structurally close analogues, real matrix (blood plasma), reproducibility, repeatability, etc. Under optimized conditions, the EQCM-MIP sensor showed linear dynamic ranges ($1-10{\mu}M$). The limit of detection 40 ppb (DPV) and 290 ppb (EQCM) was achieved without any cross reactivity and matrix effect indicating high sensitivity and selectivity for EP. Hence, an eco-friendly MIP-sensor with high sensitivity and good selectivity was fabricated which could be applied in "real" matrices in a facile manner.

전기구리도금에 미치는 Mercapto화합물의 전기화학적 특성 (The Electrochemical Characteristics of Mercapto Compounds on the Copper Electroplating)

  • 손상기;이유용;조병원;이재봉;이태희
    • 전기화학회지
    • /
    • 제4권4호
    • /
    • pp.160-165
    • /
    • 2001
  • 황산원자를 포함하는 mercapto화합물은 도금시 전착속도를 증가시키는 첨가제로 알려져 있는데, 이 중 4가지의 mercapto 화합물을 선정하여 농도를 변화시켜가며 Hull cell test, Haring-Blum cell test, cathodic polarization, EQCM(Electrochemical Quartz Crystal Microbalance)등을 이용하여 도금특성 및 throwing power를 알아보았다. Cathode polarization 및 EQCM을 통한 구리 전착량을 알아본 결과 4가지의 mercapto 화합물 중 3-mercapto-1-propanesulfonic acid가 activator로서 가장 적당하였으며, 그 농도가 20 ppm에서 throwing power를 증가시키고, 농도 및 활성 과전압이 오직 $Cl^-$만 포함되었을 때보다 cathodic scan시 100 mV 만큼 shift되어 증착속도를 증가시킴을 알 수 있었다.