• Title/Summary/Keyword: electrochemical parameters

Search Result 339, Processing Time 0.03 seconds

Electrochemical Impedance Analysis of Polyaniline-Film on Tungsten Electrodes (텅스텐 전극에 입힌 폴리아닐린의 전기화학적 임피던스)

  • Chon, Jung-Kyoon;Min, Byoung Hoon
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.1
    • /
    • pp.37-43
    • /
    • 1996
  • The electrochemical impedance spectra of polyaniline film coated on tungsten electrodes by cyclic voltammetry have been measured in 0.1 M aqueous sulfuric acid solution. An electrochemical cell composed of large redox capacitance and low resistance of PANI-film in series was in agreement with the conductive behavior reported at these potentials. When the PANI was coated on bare tungsten, the electrolytic resistance was only observed. However, on the oxidized tungsten instead of bare tungsten, the resistance of tungsten oxide and the contact resistance between PANI and tungsten oxide were additionally observed. Equivalent electrical circuits have been deduced from the impedance data. It was therfore possible to obtain the parameters of the ionic mass transport within the film.

  • PDF

Theoretical and Experimental Studies on the Adsorption of N-[(E)-Pyridin-2-ylmethylidene] Aniline, a Schiff Base, on Mild Steel Surface in Acid Media

  • N, Mohanapriya.;M, Kumaravel.;B, Lalithamani.
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.117-131
    • /
    • 2020
  • The adsorption of N-[(E)-Pyridin-2-ylmethylidene] aniline, a Schiff base, on to mild steel surface in 1M HCl and 0.5 M H2SO4 solutions and the consequent corrosion protection were studied employing weight loss method, electrochemical impedance spectroscopy and potentiodynamic polarization measurements. DFT calculations were performed to investigate its interaction with the metal surface at the atomic level to understand its inhibition mechanism. The adsorption process is well described by the Langmuir isotherm. The thermodynamic parameters indicated that the adsorption is spontaneous and the interaction of the inhibitor at the mild steel surface is mainly through physisorption. The Ra values obtained in AFM studies for the uninhibited and inhibited sample in HCl media respectively are 0.756 and 0.559 ㎛, and that in H2SO4 media are 0.411 and 0.406 ㎛. The lesser roughness values of the inhibited sample shows the adsorption of the molecules onto the mild surface. The inhibition efficiencies were found to improve with concentration of the inhibitor and the maximum efficiency was observed at 400ppm in all the investigation methods adopted. The inhibitor was found to exhibit a higher efficiency in HCl media (95.7%) than in H2SO4 (92.8%). The theoretical and experimental results are found to be in good agreement.

An Electrochemical Evaluation on the Corrosion Resistance of Heavy Anticorrosive Paint(II) (중방식 도료의 내식성에 관한 전기 화학적 평가(II))

  • Sung, Ho-Jin;Kim, Jin-Kyung;Lee, Myung-Hoon;Kim, Ki-Joon;Moon, Kyung-Man
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.382-387
    • /
    • 2005
  • An electrochemical evaluation on the corrosion resistance for heavy anticorrosive paint was carried out for 5 kinds of heavy anticorrosive paints such as High solid epoxy(HE), Solvent epoxy(SE), Tar epoxy(TE), Phenol epoxy(PE), and Ceramic epoxy(CE) as parameters of DFT(Dry Film Thickness, 25${\mu}m$50${\mu}m$, solution condition(Flow of Nonflow). Corrosion current density of HE(DFT 50${\mu}m$ in case of flow condition was larger than that of nonflow condition. However, their values of the other anticorrosive paints were decreased compared to the nonflow condition. The values of AC impedance were increased with increasing of DFT regardless of kinds of anticorrosive paints. And the polarization resistance of cyclic voltammogram showed a good tendency to correspond with well the values of AC impedance measurement. HE and CE had a relatively good corrosion resistance than other heavy anticorrosive paint.

  • PDF

Electrochemical determination of hydrogen peroxide using carbon paste biosensor bound with butadiene rubber (부타디엔 고무로 결합된 탄소반죽 바이오센서를 이용한 과산화수소의 전기화학적 정량)

  • Yoon, Kil-Joong
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.505-510
    • /
    • 2010
  • When polybutadiene dissolved in toluene was a binder of carbon powder, the volatility of solvent just after electrode fabrication assured the mechanical solidity of the carbon paste electrode. This characteristic met the qualifications for practical use of carbon paste electrodes. A new enzyme electrode bound with butadiene rubber was constructed. In order to confirm whether it shows quantitative electrochemical behaviors or not, its electrochemical kinetic parameters, e.g. the symmetry factor, the exchange current density, the capacitance of double layer, the time constant, the maximum current, the Michaelis constant and other factors were investigated. These experimental facts showed that butadiene rubber is a recommendable binder for practical use of a carbon paste electrode.

Palladium Layers on an Au(111) Nanoparticle and Their Catalytic Activity to Formic Acid Oxidation

  • Kim, Byeong-Gwon;Seo, Dae-Ha;Song, Hyeon-Jun;Gwak, Ju-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.206-206
    • /
    • 2011
  • Nanoparticles have been received great attention from many researchers for several decades because of their good and unique properties. In particular, researches in the field of synthesis of bimetallic nanoparticles showed good results for the past ten years. In this research, Pd thinlayer on Au nanoparticles were synthesized by electrochemical deposition method. Well-defined Au(111) nanoparticles were synthesized by solution based reduction method. Electrochemical deposition conditions for Pd thinlayer on Au(111) nanoparticles surface were carefully regulated by controlling parameters of cyclic voltammetry. To calculate exact mass and surface area catalytic activities of deposited Pd thinlayer on Au(111) nanoparticle, electrochemically active surface area (ECSA) and mass of the deposited Pd thinlayer were measured by cyclic voltammetry in 0.1 M HClO4 solution. Afterward, catalytic activities of the deposited Pd thinlayer were measured in 0.1 M HClO4 + 0.2 M formic acid solution. In case of less negative deposition potential, the amounts of deposited Pd mass and surface area were small. However, mass and ECSA activity of the deposited Pd to oxidize formic acid were increased.

  • PDF

CHARACTERISTICS OF LOW-TEMPERATURE PROCESSED DYE-SENSITIZED SOLAR CELL BY ELECTROCHEMICAL IMPEDANCE AND PHOTOCURRENT-PHOTOVOLTAGE TRANSIENT SPECTROSCOPY

  • Li, Yuelong;Lee, Doh-Kwon;Kim, Kyung-Kon;Ko, Min-Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.381-381
    • /
    • 2011
  • In this study, a TiO2 colloidal sol was synthesized by sol-gel process, which was used as a "glue" agent to enhance interconnection of TiO2 particles in low temperature process for plastic dye sensitized solar cell. The crystalline phase of this TiO2 glue is pure anatase with average particles size of 5 nm, which was characterized by powder X-ray diffraction and high revolution-TEM. The viscous alcoholic paste without any organic binder was prepared from the mixture of commercial P25 powder and glue. Paste composition and sintering process parameters were optimized for high photovoltaic performance based on low temperature process. The electrochemical impedance spectroscopy and photocurrent-photovoltage transient spectroscopy were also employed to investigate the mechanism of electron transport in this binder free TiO2 film system.

  • PDF

Effect of Preparation Parameters of Sulfur Cathodes on Electrochemical Properties of Lithium Sulfur Battery

  • Zhao, Xiaohui;Kim, Dul-Sun;Ahn, Hyo-Jun;Kim, Ki-Won;Jin, Chang-Soo;Ahn, Jou-Hyeon
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.3
    • /
    • pp.169-174
    • /
    • 2010
  • Sulfur cathodes were prepared by ball milling method with different types of electronic conductors and binders in different ball milling time. The sulfur cell with a cathode prepared in 45 min ball milling time gave an initial discharge capacity of 794mAh/g with Super-P as an electronic conductor and poly(vinylidene fluoride) as a binder. The cathode with multi-walled carbon nanotube as an electronic conductor showed an initial discharge capacity of 944 mAh/g and a discharge capacity of 300 mAh/g after 20 cycles. Cathodes with poly(ethylene oxide) and poly(vinylidene fluoride) as binders showed different cycle performance.

Electrochemical Investigation of Acetaminophen with a Carbon Nano-tube Composite Film Electrode

  • Li, Chunya;Zhan, Guoqing;Yang, Qingdan;Lu, Jianjie
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.11
    • /
    • pp.1854-1860
    • /
    • 2006
  • Electrochemical behaviors of acetaminophen at a muti-wall carbon nano-tube composite film modified glassy carbon electrode were investigated by cyclic voltammetry, linear sweep voltammetry and chronocoulometry. Compared with that obtained at the unmodified electrode, the peak currents were enhanced significantly, and the oxidation peak shifted towards more negative potential with the reduction peak shifted positively. The peak-to-peak separation turned narrow, and suggested that the reversibility was improved greatly. Experimental parameters, such as scan rate, pH and accumulation conditions were optimized. It was found that a maximum current response can be obtained at pH = 5.0 after accumulation at -0.50 V for 80 s. The oxidation peak current was found to be linearly related to acetaminophen concentration over the range of $5.0{\times}10^{-7}\;\sim\;1.0{\times}10^{-4}$ mol $L^{-1}$ with a detection limit of $5.0{\times}10^{-8} $mol $L^{-1}$. A convenient and sensitive electrochemical method was developed for the determination of acetaminophen in a commercial paracetamol oral solution. Its practical application demonstrated that it has good selectivity and high sensitivity.

Determination of Optimum pH of Enzyme by Electrochemical Method (전기화학적 방법에 의한 효소의 최적 pH 결정)

  • Yoon, Kil-Joong;Lee, Beom-Gyu;Kwon, Hyo-Shik
    • Analytical Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.41-48
    • /
    • 2000
  • A biosensor for the determination of hydrogen peroxide was constructed by immobilizing of porcine small instestinal tissue in a plain carbon paste, and the effect of varying the $H_2O_2$ concentration and pH on the rate of catalytic reaction was evaluated. For the mathematical simplicity, no mediator was added. Electrochemical properties and the maximal rate could be derived from the quantitative analysis of the observed phenomena related to the electrode reaction. Also, pH dependence of the Michaelis constant enabled to calculate various thermodynamic parameters and subsequently to design a electrochemical method to determine the optimum pH of enzyme.

  • PDF

Characterization of Ceramic Oxide Layer Produced on Commercial Al Alloy by Plasma Electrolytic Oxidation in Various KOH Concentrations

  • Lee, Jung-Hyung;Kim, Seong-Jong
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.2
    • /
    • pp.119-124
    • /
    • 2016
  • Plasma electrolytic oxidation (PEO) is a promising coating process to produce ceramic oxide on valve metals such as Al, Mg and Ti. The PEO coating is carried out with a dilute alkaline electrolyte solution using a similar technique to conventional anodizing. The coating process involves multiple process parameters which can influence the surface properties of the resultant coating, including power mode, electrolyte solution, substrate, and process time. In this study, ceramic oxide coatings were prepared on commercial Al alloy in electrolytes with different KOH concentrations (0.5 ~ 4 g/L) by plasma electrolytic oxidation. Microstructural and electrochemical characterization were conducted to investigate the effects of electrolyte concentration on the microstructure and electrochemical characteristics of PEO coating. It was revealed that KOH concentration exert a great influence not only on voltage-time responses during PEO process but also on surface morphology of the coating. In the voltage-time response, the dielectric breakdown voltage tended to decrease with increasing KOH concentration, possibly due to difference in solution conductivity. The surface morphology was pancake-like with lower KOH concentration, while a mixed form of reticulate and pancake structures was observed for higher KOH concentration. The KOH concentration was found to have little effect on the electrochemical characteristics of coating, although PEO treatment improved the corrosion resistance of the substrate material significantly.