• Title/Summary/Keyword: electro-osmotic consolidation

Search Result 3, Processing Time 0.016 seconds

The Study on permeability enhancement in smear zone using electro-osmotic pressure (전기 삼투압을 이용한 교란영역의 투수성 개선에 관한 연구)

  • Ahn, Byung-Wook;Noh, Hee-Jeon;Kim, Hyun-Ki;Cho, Nam-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.435-441
    • /
    • 2008
  • More time is required for consolidating soft clay when its hydraulic conductivity around the vertical drains is reduced by soil disturbance. One of the methods to be proposed to solve such problem is the electro-osmotic flow application. This study presents the experimental results of model tests using a modified oedometer and a large-scale cylinder with a sand drain. Results show that the development of negative excessive pore water pressure due to the DC electrical field in saturated clay can be transformed to additional loads causing more consolidation settlement.

  • PDF

Effect of electrochemical treatment on consolidation of soft clay

  • Li, Xiaobing;Yuan, Guohui;Fu, Hongtao;Wang, Jun;Cai, Yuanqiang
    • Geomechanics and Engineering
    • /
    • v.15 no.4
    • /
    • pp.957-964
    • /
    • 2018
  • In this study, a method of electrochemical consolidation is applied. This method utilizes electro-osmosis, which is an effective ground improvement technique for soft clays, and soil treatment using lime, which is the oldest traditional soil stabilizer. The mechanism of lime treatment for soil involves cation exchange, which leads to the flocculation and agglomeration. Five representative laboratory tests-an electro-osmotic test and four electrochemical tests with various proportions of lime-were performed on dredged marine clay. The objectives of this study are to investigate the effect of electrochemical treatment and to determine the optimum dose for optimal consolidation performance of dredged marine clay. The results show that a better consolidation effect was achieved in terms of current, temperature, and vane shear strength by using electrochemical treatment. The best results were observed for the electrochemical test using 4% lime content.