• Title/Summary/Keyword: electro fusion

Search Result 51, Processing Time 0.03 seconds

A Study of Electro-foaming Fusion Wrap for Polyethylene Sewer Pipe (폴리에틸렌 하수관 연결용 전기발포융착 이음관에 관한 연구)

  • Kye, Hyoung-San;Joo, Kyung-Hoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.343-354
    • /
    • 2012
  • A electro-foaming fusion wrap fitting for polyethylene sewer pipe was built and foaming mechanism has been studied. A foaming sheet, supporting sheet and clamping band is assembled into a all-in-one structured electro-foaming fusion wrap fitting. To specify foaming and fusion of electro-foaming fusion wrap for PE sewer pipe, series of fusion tests were performed in various conditions. A parallel plate compression test up to 50 % of inner diameter deflection has been performed to check integrity of fusion quality and it was found that there were no visible signs of crack in wrapped area of fitting. Also air tightness test based on KS M 3511-2 has been performed to evaluate perfectness of wrap fusion quality and we found there were no pressure drop up to 10 times higher value than KS standard regulation.

HY Simplified Synthetic Test Facility (한양대학교 간이차단 합성시험설비구축)

  • Chang, Yong-Moo;Hwang, Ryul;Kim, Cheol-Ho;Lee, Bang-Wook;Koo, Ja-Yoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.220-220
    • /
    • 2009
  • We are developing of the evaluation technique and system for testing the performance of circuit breaker using Simplified Synthetic circuit. This facility specification is up to 90[kApeak] and up to 300[kVpeak]. It is possible to verify the interrupting capability by using low-energy and reduce the development period and the cost.

  • PDF

HY 1600kV/70kA Impulse Voltage/Current Test Facility (한양대학교 1600kV/70kA 충격 전압/전류 시험설비 구축)

  • Chang, Yong-Moo;Kim, Cheol-Ho;Hwang, Ryul;Lee, Bang-Wook;Koo, Ja-Yoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.229-229
    • /
    • 2009
  • This Impulse Voltage and Current Test System is designed for performing of impulse voltage tests with Lightning impulse voltage 1.2/50(LI) up to 1520kV peak value and switching impulse voltages 250/2500(SI) up to 1120kV peak valu acc. to IEC 60060-1, and furthermore for impulse current test, e.g. testing of arrester sections($U_{res}$=95kV)with current impulses 4/10 and 8/20 up to 70kA peak value.

  • PDF

Temperature dependent electro-optical studies of liquid crystal in Fringe Field Switching (FFS), In-plane switching (IPS), and Patterned Vertical Alignment (PVA) modes

  • Jo, Eun-Mi;Srivastava, Anoop Kumar;Kim, Mi-Young;Kim, Sung-Min;Lee, Seung-Hee;Ji, Seung-Hoon;Lee, Gi-Dong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.320-323
    • /
    • 2008
  • In this paper, electro-optical characteristic of Nematic Liquid crystal (LC) with varying temperature in different LCD modes, namely Fringe Field Switching (FFS), In-plane switching (IPS), and Patterned Vertical Alignment (PVA) modes are investigated and compared. Electro optic me asurements suggest that rate of change of transmission with temperature in FFS mode was lowest and much more thermally stable as compared to IPS and PVA m odes. However the electro-optical characteristic of patterned vertical alignment (PVA) mode was most affected by changing temperature. The measured threshold voltage was found to be much more thermally stable in FFS and IPS modes than that of PVA mode.

  • PDF

Temperature Dependence of the Electro-optic Characteristics in the Liquid Crystal Display Switching Modes

  • Jeon, Eun-Jeong;Srivastava, Anoop Kumar;Kim, Mi-Young;Jeong, Kwang-Un;Choi, Jeong-Min;Lee, Gi-Dong;Lee, Seung-Hee
    • Journal of Information Display
    • /
    • v.10 no.4
    • /
    • pp.175-179
    • /
    • 2009
  • As the physical properties of nematic liquid crystals vary with respect to temperature, the performances of liquid crystal displays (LCDs) are highly dependent on temperature. Additionally, it is well known that the electro-optic characteristics of LCDs, such as transmittance and threshold voltage, also rely on the LCD switching modes. The temperature dependence of the electro-optic characteristics of the wide-viewing-angle LCD modes, such as in-plane switching (IPS), multidomain vertical alignment by patterned electrode (PVA), and fringe-field switching (FFS), have been studied, and the results showed that the FFS mode has lower temperature dependence compared to the IPS and PVA modes. Since the liquid crystal (LC) reorients in different ways in each mode, this result is associated with the temperature dependence of LC's bend and twist elastic constants, and also with the position of the main reorientation, either in the middle or on the surface of the LC layer.

Study on electro-optic characteristics of FFS mode using a positive LC (양의 액정을 이용한 Fringe Field Switching mode의 전기-광학 특성 연구)

  • Woo, Chang-Woo;Ha, Kyung-Su;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.171-171
    • /
    • 2010
  • Electro-optic characteristics of liquid crystal display using fringe field switching(FFS) device depend on many parameters such as cell retardation, electrode structure, rubbing angle, cell gap and dielectric anisotropy. In this paper, the light efficiency of FFS mode will be analyzed to confirm the electro-optic characteristics according to positive dielectric anisotropy such as transmittance, operating voltage and response time.

  • PDF

Investigation on High Transmittance Vertical Alignment (VA) display associated with Surface Polymer Stabilization (표면 고분자 안정화를 이용한 고 광효율 VA 디스플레이 연구)

  • Kim, Woo-Il;Kim, Sung-Min;Cho, In-Young;Kim, Dae-Hyun;Kwon, Dong-Won;Jeong, Yeon-Hak;Ryu, Jae-Jin;Kim, Kyeong-Hyeon;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.39-40
    • /
    • 2009
  • The patterned vertical alignment (PVA) display showed good electro-optic properties such as wide viewing angle, fast response time, high Contrast Ratio. However, the device has patterned electrode on both top and bottom electrodes which requires high accuracy of assembling of top and bottom substrates in order to exhibit a high performance. So, they have disadvantage about low yield. In order to resolve these problem, in this paper, we studied about top substrate pattern free vertical alignment device associated with surface polymer stabilization using the UV curable monomer. This method shows simple progress, low cost and good electro-optic properties such as high transmittance and fast response time.

  • PDF

Development of an Integrated Power Market Simulator for the Korean Electricity Market

  • Hur Jin;Kang Dong-Joo;Moon Young-Hwan
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.4
    • /
    • pp.416-424
    • /
    • 2005
  • At present, the Korean electricity industry is undergoing restructuring and the Cost Based-generation Pool (CBP) market is being operated in preparation of a Two Way Bidding Pool (TWBP) market. In deregulated electricity industries, an integrated power market simulator is one of the tools that can be used by market participants and market operators analyzing market behaviors and studying market structures and market codes. In this regard, it is very important to develop an electricity market simulator that reflects market code providing a market operation mechanism. This paper presents the development of an integrated market simulator, called the Power Exchange Simulator (PEXSIM), which is designed to imitate the Korean electricity market considering the various features of the market operating mechanism such as uniform price and constrained on/off payment. The PEXSIM is developed in VB.NET and composed of five modules whose titles are M-SIM, P-SIM, O-SIM, T-SIM and G-SIM interfacing the Access database program. To verify the features and the performance of the PEXSIM, a small Two Way bidding market with a 12-bus system and a One Way bidding market for generator competition will be presented for the electricity market simulations using PEXSIM.

Study on Electro-opt ic Characteristics in the Optically Compensated Splay Cell with UV-curable Reactive Mesogen

  • Kim, Seong-Su;Jeon, Eun-Jeong;Lee, Myong-Hoon;Lee, Seung-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.327-329
    • /
    • 2008
  • We have studied the optically compensated splay (OCS) mode using reactive mesogen monomer to reduce critical voltage, setting voltage and phase transition time from initial bend to splay state. The high pretilt angle from vertical alignment was formed through the polymerization of UV curable RM monomer at the surfaces. In this way, orientation of the LC with OCS can be achieved without setting voltage.

  • PDF

Classification of Fused SAR/EO Images Using Transformation of Fusion Classification Class Label

  • Ye, Chul-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.6
    • /
    • pp.671-682
    • /
    • 2012
  • Strong backscattering features from high-resolution Synthetic Aperture Rader (SAR) image provide useful information to analyze earth surface characteristics such as man-made objects in urban areas. The SAR image has, however, some limitations on description of detail information in urban areas compared to optical images. In this paper, we propose a new classification method using a fused SAR and Electro-Optical (EO) image, which provides more informative classification result than that of a single-sensor SAR image classification. The experimental results showed that the proposed method achieved successful results in combination of the SAR image classification and EO image characteristics.