• 제목/요약/키워드: electricity generation

검색결과 1,056건 처리시간 0.188초

공학적인 지열시스템(EGS)을 이용한 지열발전 기술 (Geothermal Power Generation using Enhanced or Engineered Geothermal System(EGS))

  • 한정상;한혁상
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.3-32
    • /
    • 2008
  • The potential deep geothermal resources span a wide range of heat sources from the earth, including not only the more easily developed, currently economic hydrothermal resources; but also the earth's deeper, stored thermal energy, which is present anywhere. At shallow depths of 3,000~10,000m, the coincidence of substantial amounts heat in hot rock, fluids that heat up while flowing through the rock and permeability of connected fractures can result in natural hot water reservoirs. Although conventional hydrothermal resources which contain sufficient fluids at high temperatures and geo-pressures are used effectively for both electric and nonelectric applications in the world, they are somewhat limited in their location and ultimate potential for supplying electricity. A large portion of the world's geothermal resource base consists of hot dry rock(HDR) with limited permeability and porosity, an inadquate recharge of fluids and/or insufficient water for heat transport. An alternative known as engineered or enhanced geothermal systems(EGS), to dependence on naturally occurring hydrothermal reservoirs involves human intervention to engineer hydrothermal reservoirs in hot rocks for commercial use. Therefore EGS resources are with enormous potential for primary energy recovery using an engineered heat mining technology, which is designed to extract and utilize the earth's stored inexthermal energy. Because EGS resources have a large potential for the long term, United States focused his effort to provide 100GW of 24-hour-a-day base load electric-generating capacity by 2050.

  • PDF

에너지효율향상의무화제도의 국내 도입을 위한 기반구축 연구 - 에너지수요관리제도 및 절감률 산정 중심으로 - (A Study on Establishing Infrastructure Plans to Introduce an Energy Efficiency Resource Standards - Based on the Energy Demand Side Management and Energy Efficiency Potential -)

  • 홍성준;최봉하;이덕기;박수억;원종률
    • 한국수소및신에너지학회논문집
    • /
    • 제21권3호
    • /
    • pp.241-247
    • /
    • 2010
  • An Energy Efficiency Resource Standards (EERS) is a simple, market-based mechanism to encourage more efficient generation, transmission, and use of electricity, natural gas and heat. An EERS consists of electric, gas and/or heating energy savings targets for utilities, often with flexibility to achieve the target through a market-based trading system. In this paper, we make persons acquainted with EERS programs of foreign countries in these days. And we analyze domestic energy demand side management (DSM) programs in order to introduce an EERS program into the country successfully. Energy efficiency potential calculated in 2007 is one of the important factors for establishing an EERS program domestically. This study may provide basic data to set the amount of energy saving when an EERS program would be phased in.

변압기 이상음의 초음파 분석에 관한 연구 (A study on ultrasound analysis of the transformer strange signal)

  • 백화종;지석근
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2002년도 추계종합학술대회
    • /
    • pp.835-838
    • /
    • 2002
  • 동작되고 있는 고전압 기기는 전기의 독특한 특성 때문에 초음파 방출을 유발하는 특유한 소리를 방출한다. 초음파 방출이란 아킹, 코로나, 트래킹과 같은 전기적변화에 의해서 발생된다 고전압 전력 설비에서 아킹, 코로나, 트래킹은 여러 가지 장애를 일으킬 뿐만 아니라 인체에도 매우 치명적인 손상을 야기한다. 고전압 기기의 장애 요소를 방지하고 사전에 진단하기 위해 초음파 측정이 주목받게 되었지만 아직까지 기초적인 측정 데이터가 충분히 제시되어 있지 않은 실정이다. 본 논문에서는 변압기 설비에서 발생하는 초음파 이상음을 분석하고 분석한 자료를 표준 데이터화 하는데 그 목적을 둔다.

  • PDF

최적조류계산을 이용한 한계손실계수의 전력시장 적용 (Marginal Loss Factor using Optimal Power flow in Power Market)

  • 신동준;고용준;이효상;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권8호
    • /
    • pp.379-384
    • /
    • 2002
  • In the competitive electricity market, various pricing methods are developed and practiced in many countries. Among these pricing methods, marginal loss factor(MLF) can be applied to reflect the marginal cost of network losses. For the calculation of MLF, power flow method has been used to calculate system loss deviation. However, this power flow method shows some shortcomings such as necessity of regional reference node, and absence of an ability to consider network constraints like line congestion, voltage limit, and generation output limit. The former defect might affects adversely to the equity of market participants and the latter might generate an inappropriate price signals to customers and generators. To overcome these defects, the utilization of optimal power flow(OPF) is suggested to get the system loss deviation in this paper. 30-bus system is used for the case study to compare the MLF results by the power flow and the OPF method for 24-hour dispatching and pricing, Generator payment and customer charge are compared with these two methods also. The results show that MLF by OPF reflects the power system condition more faithfully than that of by the conventional power flow method

Research into The Future Development of the Hybrid System for Buoy

  • Lee, Ji-Young;Kim, Jong-Do;Lee, Jong-Ho;Lee, Jin-Yeol;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.583-591
    • /
    • 2007
  • This paper reports the performance of a 150W PV-wave hybrid system with battery storage in buoy. This system was originally designed to meet a new hybrid ower system for buoy in Korea. In the case or lighted buoys and lighthouses, a light failure alarm system of wireless radio is attached so that light failures are immediately notified to the office. At lighthouse offshore fixed lights and light buoys where commercial electricity is not available, the power source depends on solar system and batteries. This power system has a various problems. Therefore energy derived from the sunshine, wind and waves has been used as the energy source lot aids to navigation. Recently a hybrid system of combining the solar, wind and the wave generator is a favorable system lot the ocean facilities like lighthouse and buoy. The hybrid system in this paper is intended for variable DC load like light, communication system in the buoy and includes a PV-wane generation system and battery. This is composed a high efficiency charging algorithm, switching converter and controller. This paper includes discussion on system reliability, power quality, and effects of hybrid system in the buoy. Simulation and experimental results show excellent performance.

일체형원자로의 신개념 안전계통 실증을 위한 실험적 연구 (Experimental Study on Design Verification of New Concept for Integral Reactor Safety System)

  • 정문기;최기용;박현식;조석;박춘경;이성재;송철화
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2053-2058
    • /
    • 2004
  • The pressurized light water cooled, medium power (330 MWt) SMART (System-integrated Modular Advanced ReacTor) has been under development at KAERI for a dual purpose : seawater desalination and electricity generation. The SMART design verification phase was followed to conduct various separate effects tests and comprehensive integral effect tests. The high temperature / high pressure thermal-hydraulic test facility, VISTA(Experimental Verification by Integral Simulation of Transient and Accidents) has been constructed to simulate the SMART-P (the one fifth scaled pilot plant) by KAERI. Experimental tests have been performed to investigate the thermal-hydraulic dynamic characteristics of the primary and the secondary systems. Heat transfer characteristics and natural circulation performance of the PRHRS (Passive Residual Heat Removal System) of SMART-P were also investigated using the VISTA facility. The coolant flows steadily in the natural circulation loop which is composed of the steam generator (SG) primary side, the secondary system, and the PRHRS. The heat transfers through the PRHRS heat exchanger and ECT are sufficient enough to enable the natural circulation of the coolant.

  • PDF

제한요소를 고려한 가스터빈-가압형 SOFC 하이브리드 시스템의 성능특성 해석 (Analysis of Performance Characteristics of Gas Turbine-Pressurized SOFC Hybrid Systems Considering Limiting Design Factors)

  • 양원준;김동섭;김재환
    • 설비공학논문집
    • /
    • 제16권11호
    • /
    • pp.1013-1020
    • /
    • 2004
  • The hybrid system of gas turbine and fuel cell is expected to produce electricity more efficiently than conventional methods, especially in small power applications such as distributed generation. The solid oxide fuel cell (SOFC) is currently the most promising fuel cell for the hybrid system. To realize the conceptual advantages resulting from the hybridization of gas turbine and fuel cell, optimized construction of the whole system must be the most important. In this study, parametric design analyses for pressurized GT/SOFC systems have been peformed considering probable practical limiting design factors such as turbine inlet temperature, fuel cell operating temperature, temperature rise in the fuel cell and soon. Analyzed systems include various configurations depending on fuel reforming type and fuel supply method.

The Application of Project control Techniques to Process Control: The Effect of Temporal Information on Human Monitoring Tasks

  • Parush, A.;Shtub, A.;Shavit, D.
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제3권1호
    • /
    • pp.10-14
    • /
    • 2001
  • We studied the use of time-related information, with and without prediction, to support human operators performing moni-toring and control tasks in the process. Based on monitoring and control techniques used for Project Management we developed a display design for the process industries. A simulated power plant was used to test the hypothesis that availability of predictions along with information on past trends can improve the performances of the human operator handling faults. Several designs of dis-plays were tested in the experiment in which human operators had to detect and handle two types of faults(local and systems wide) in the simulated electricity generation process. Analysis of the results revealed that temporal data, with and without prediction, signifi-cantly reduced response time. Our results encourage the integration of temporal information and prediction in displays used for the control processes to enhance the capabilities of the human operators. Based on the analysis we proposed some guidelines for the de-signer of the human interface of a process control system.

  • PDF

격자 구조의 실내 환경을 고려한 LED 무선 통신 채널 특성에 관한 연구 (A Study of LED Wireless Communication Channel Characteristics considering Latticed Indoor Circumstance)

  • 이정훈;강장묵;조주필;김윤현;김진영;차재상
    • 한국인터넷방송통신학회논문지
    • /
    • 제11권4호
    • /
    • pp.203-207
    • /
    • 2011
  • LED(Lighting emitted diode)는 전기 에너지를 빛으로 변환하는 효율이 좋고 수명이 길어서 차세대 조명으로 관심 받고 있으며, 최근에 자동차의 후미등, 신호등, 실내등에 사용되고 있다. 부가적인 기능으로서 LED를 이용하여 데이터 정보를 조명과 동시에 전송하는 융합(Convergence) 기술에 대한 연구가 진행되고 있다. 본 논문에서는 실내 환경을 1mm 단위의 격자 형태로 분할하고 LED에서 출발한 광입자가 격자에 도달한 후에 반사되어 직선 운동을 하다가 포토다이오도(PD)에 도달하는 원리를 이용하여 LED 무선 채널의 특성을 연구한다.

다중 물 분사 노즐이 장착된 감온밸브의 해석 연구 (An Analysis Study on Desuperheater valve attachment on Multi Water Spray Nozzles)

  • 이덕구;조행훈;조남철;이채문
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.74-79
    • /
    • 2009
  • The generation of electric power and plant facilities have been attempting to improve energy efficiency with many efforts as those being basis of our country's economy. In particular, the CHP(Combined Heat Power plant) system, is producing the electricity and process steam, has generally been using for the cogeneration plants. When CHP system operates, the steam has to maintain the high temperature and high pressure in order to have high efficiency of electric power production as much as possible. In addition, the exhausted steam from the turbine has to reform proper temperature to use the needed process. The major purpose of desuperheater is that the superheated steam changes into the saturated steam because it is more efficient and suitable for using the process, furthermore, it is more convenient and stable regarding the process temperature control. The design of the desuperheater obtained through the experiment and preceding analysis. This paper is verified by analysis that water spray nozzle(${\Phi}$=28mm) shows the best ability under the real power plant condition.

  • PDF