• Title/Summary/Keyword: electrical therapy

Search Result 617, Processing Time 0.026 seconds

Trends and Analysis of Cancer Incidence for Common Male and Female Cancers in the Population of Punjab Province of Pakistan during 1984 to 2014

  • Masood, Khalid;Masood, Andleeb;Zafar, Junaid;Shahid, Abubaker;Kamran, Mujahid;Murad, Sohail;Masood, Misbah;Alluddin, Zafar;Riaz, Masooma;Akhter, Naseem;Ahmad, Munir;Ahmad, Fayyaz;Akhtar, Javaid;Naeem, Muhammad
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.13
    • /
    • pp.5297-5304
    • /
    • 2015
  • Background: The Pakistan Atomic Energy Commission Cancer Registry (PAECCR) program has made availability of a common cancer incidence database possible in Pakistan. The cancer incidence data from nuclear medicine and oncology institutes were gathered and presented. Materials and Methods: The cancer incidence data for the last 30 years (1984-2014) are included to describe a data set of male and female patients. The data analysis concerning occurrence, trends of common cancers in male and female patients, stage-wise distribution, and mortality/follow-up cases is also incorporated for the last 10 years (2004-2014). Results: The total population of provincial capital Lahore is 9,800,000. The total number of cancer cases was 80,390 (males 32,156, females 48,134). The crude incidence rates in PAECCR areas were 580.8/$10^5$ during 2010 to 885.4/$10^5$ in 2014 (males 354.1/$10^5$, females 530.1/$10^5$). The cancer incidence rates for head and neck (15.70%), brain tumors (10.5%), and non-Hodgkin lymphoma (NHL, 9.53%) were found to be the highest in male patients, whereas breast cancer (46.7%), ovary tumors (6.80%), and cervix (6.31%) cancer incidence rates were observed to be the most common in female patients. The age range distribution of diagnosed and treated patients in conjunction with the percentage contribution of cancer patients from 15 different cities of Punjab province treated at the Institute of Nuclear Medicine and Oncology, Lahore are also included. Leukemia was found to be the most common cancer for the age group of 1-12 years. It has been identified that the maximum number of diagnosed cases were found in the age range of 51-60 years for males and 41-50 years for female cancer patients. Conclusions: Overall cancer incidence of the thirty years demonstrated that head and neck and breast cancers in males and in females respectively are the most common cancers in Punjab province in Pakistan, at rates almost the highest in Asia, requiring especial attention. The incidence of brain, NHL, and prostate cancers among males and ovarian and cervix cancers among females have increased rapidly. These data from a major population of Punjab province should be helpful for implementation of appropriate planning, prevention and cancer control measures and for determination of risk factors within the country.

Blood Flow Changes in the Masseter Muscle and Overlying Skin Following Various Functional Waves of Transcutaneous Electrical Nerve Stimulation (경피신경자극치료기(TENS)의 기능별 주파수에 따른 교근과 피개상피의 혈류변화에 관한 연구)

  • Cho, Sung-Guk;Auh, Q-Schick;Chun, Yang-Hyun;Hong, Jung-Pyo
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.1
    • /
    • pp.115-122
    • /
    • 2009
  • The following results were obtained, after experimenting on change of masseter muscle and bloodstream epithelium with Transcutaneous Electrical Nerve Stimulator(TENS), among 16 male adults. 1. According to applying TENS, it was observed that bloodstream in muscle increases at 1.5, 3.0 Hz. 2. According to applying TENS, it was observed that concentration of moving blood cells in muscle increase at 1.5, 3.0, 6.0 Hz. 3. According to applying TENS, it was observed that velocity of bloodstream in muscle increases only at 1.5 Hz 4. Through experiment, applying TENS at level of 6.0 and 10.0 Hz, all bloodstream, concentration of moving blood cells, and velocity of bloodstream increasing rates were lower in muscle compared to of them in overlying epithelium; and especially increasing bloodstream and its velocity were most frequent at 6.0 Hz, and bloodstream of 10.0 Hz. From the results above when a physical therapy of TENS is carried out the frequency of 1.5, 3.0 H is effective, and as the frequency increases it is disadvantageous to the muscle.

Experience with the Application of Magnetic Resonance Diagnostic $Analyser^{(R)}$ -A case of reflex sympathetic dystrophy- (자기공명분석기에 의한 반사성 교감신경성 위축증의 치험)

  • Kim, Jin-Soo;Kwak, Su-Dal;Kim, Jun-Soon;Ok, Sy-Young;Cha, Young-Deog;Park, Wook
    • The Korean Journal of Pain
    • /
    • v.6 no.2
    • /
    • pp.275-279
    • /
    • 1993
  • Reflex sympathetic dystrophy is a syndrome characterized by persistent, burning pain, hyperpathia, allodynia & hyperaesthesia in an extremity, with concurrent evidence of autonomic nervous system dysfunction. It generally develops after nerve injury, trauma, surgery, et al. The most successful therapies are directed towards blocking the sympathetic intervention to the affected extremity by regional sympathetic ganglion block or Bier block with sympathetic blocker; other traditional treatments include transcutaneous electrical stimulation, immobilization with cast & splint, physical therapy, psychotherapy, administration of sympathetic blocker, calcitonin, corticosteroid and analgesic agents. The purpose of this report is to evaluate and describe the effects of magnetic resonance following unsatisfactory results with traditional treatments of RSD. A 17 year old female patient, 1 year earlier, had received excision and drainage of pus at the right femoral triangle due to an injury caused by a stone. Afterwards, she experienced burning pain, knee joint stiffness, and muscle dystrophy of the right thigh, especially when standing and walking. Despite a year of number of traditional treatments such as: lumbar sympathetic block, continuous epidural analgesia, transcutaneous electrical stimulation, & administration of predisolone, her pain did not improve. Surprisingly, the patients was able to walk free from pain and difficulty after just one application of magnetic resonance. The patient has been successfully treated with further treatment of two to three times a week for approximately ten weeks. More recently, magnetic resonance has been demonstrated to produce effective results for the relief of pain in a variety of diseases. From our experiences we recognize magnetic resonance as a therapeutic modality which can provide excellent results for the treatment of RSD. It has been suggested that polysynaptic reflex which are disturbed in RSD may be modulated normally on the spinal cord level through the application of magnetic resonance.

  • PDF

Self-management techniques and subsequent changes in pain and function in patients with chronic low back pain (만성 요통 환자의 자가 관리 요법에 따른 통증 및 기능의 변화)

  • Choi, Jun Hyun;Kim, Eun-Shil;Yoon, Yong-Soon;Kim, Ka-Eun;Lee, Mi-Hyun;Jang, Hong-Young
    • Journal of Digital Convergence
    • /
    • v.18 no.10
    • /
    • pp.547-555
    • /
    • 2020
  • To investigate the effects of self-management programs for chronic low back pain (LBP), 63 subjects were assigned to three groups; self-exercise group (SEG), hot pack and low-frequency electrical stimulation group (HEG), and thermo-massage group (TMG). Parameters were the pain numeric rating scale (PNRS), Oswestry Disability Index (ODI), Roland Morris Disability Questionnaire (RMDQ) and Relapse frequency (RF). PNRS, ODI and RMDQ of SEG and TMG sustained effectiveness, however, PNRS, which improved after treatment in HEG, worsened in 6 month. Between the groups, all parameters were better in SEG and TMG compare to HEG. Exercise and thermo-massage can be considered as useful self-management performed at home to prevent the relapse of chronic LBP.

Development of a Pacemaker with a Ventricular Assist Device for End-Stage Heart Failure Patients (말기 심질환 환자를 위한 심실보조장치용 심박조율기의 개발)

  • Kim, Yoo-Seok;Park, Sung-Min;Choi, Seong-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1205-1211
    • /
    • 2011
  • In this paper, we developed a pacemaker that can increase the efficacy of a left ventricular assist device (LVAD) and increase the survival rate for patients suffering end-stage heart failure. Because LVAD patients can experience arrhythmia, the pacemaker incorporated into the LVAD has the important role of sustaining sufficient blood circulation during arrhythmia. The electrode of the pacemaker is located at the apex of the left ventricle, where the VAD's inlet cannula is connected. This is efficient placement, in that the electrode can transmit electrical stimulation directly to the Purkinje fibers of the myocardium. The pacemaker can change the stimulation rate from 0 bpm to 191.4 bpm when a button is pressed on the external control module, and the pacemaker normally stimulates the heart at 60 bpm with 0.25 J of energy. We performed animal experiments to evaluate the performance and reliability of the combination of the LVAD and pacemaker. At pacemaker stimulation rates of 86.4 bpm, 100.2 bpm, 126.6 bpm, we recorded the ECGs, aortic pressures, and flow rates to analyze the heart loads.

Simulation of the High Frequency Hyperthermia for Tumor Treatment (종양치료용 고주파 열치료 인체적용 시뮬레이션)

  • Lee, Kang-Yeon;Jung, Byung-Geun;Kim, Ji-won;Park, Jeong-Suk;Jeong, Byeong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.3
    • /
    • pp.257-263
    • /
    • 2018
  • Hyperthermia supplies RF high-frequency energy above 1MHz to the tumor tissue through the electrodes. And the temperature of the tumor tissue is increased to $42^{\circ}C$ or more to cause thermal necrosis. A mathematical model can be derived a human body model for absorption and transmission of electromagnetic energy in the human model and It is possible to evaluate the distribution of temperature fields in biological tissues. In this paper, we build the human model based on the adult standard model of the geometric shape of the 3D model and use the FVM code. It is assumed that Joule heat is supplied to the anatomical model to simulate the magnetic field induced by the external electrode and the temperature distribution was analyzed for 0-1,200 seconds. As a result of the simulation, it was confirmed that the transferred energy progressively penetrates from the edge of the electrode to the pulmonary tumors and from the skin surface to the subcutaneous layer.

High Performance Flexible Inorganic Electronic Systems

  • Park, Gwi-Il;Lee, Geon-Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.115-116
    • /
    • 2012
  • The demand for flexible electronic systems such as wearable computers, E-paper, and flexible displays has increased due to their advantages of excellent portability, conformal contact with curved surfaces, light weight, and human friendly interfaces over present rigid electronic systems. This seminar introduces three recent progresses that can extend the application of high performance flexible inorganic electronics. The first part of this seminar will introduce a RRAM with a one transistor-one memristor (1T-1M) arrays on flexible substrates. Flexible memory is an essential part of electronics for data processing, storage, and radio frequency (RF) communication and thus a key element to realize such flexible electronic systems. Although several emerging memory technologies, including resistive switching memory, have been proposed, the cell-to-cell interference issue has to be overcome for flexible and high performance nonvolatile memory applications. The cell-to-cell interference between neighbouring memory cells occurs due to leakage current paths through adjacent low resistance state cells and induces not only unnecessary power consumption but also a misreading problem, a fatal obstacle in memory operation. To fabricate a fully functional flexible memory and prevent these unwanted effects, we integrated high performance flexible single crystal silicon transistors with an amorphous titanium oxide (a-TiO2) based memristor to control the logic state of memory. The $8{\times}8$ NOR type 1T-1M RRAM demonstrated the first random access memory operation on flexible substrates by controlling each memory unit cell independently. The second part of the seminar will discuss the flexible GaN LED on LCP substrates for implantable biosensor. Inorganic III-V light emitting diodes (LEDs) have superior characteristics, such as long-term stability, high efficiency, and strong brightness compared to conventional incandescent lamps and OLED. However, due to the brittle property of bulk inorganic semiconductor materials, III-V LED limits its applications in the field of high performance flexible electronics. This seminar introduces the first flexible and implantable GaN LED on plastic substrates that is transferred from bulk GaN on Si substrates. The superb properties of the flexible GaN thin film in terms of its wide band gap and high efficiency enable the dramatic extension of not only consumer electronic applications but also the biosensing scale. The flexible white LEDs are demonstrated for the feasibility of using a white light source for future flexible BLU devices. Finally a water-resist and a biocompatible PTFE-coated flexible LED biosensor can detect PSA at a detection limit of 1 ng/mL. These results show that the nitride-based flexible LED can be used as the future flexible display technology and a type of implantable LED biosensor for a therapy tool. The final part of this seminar will introduce a highly efficient and printable BaTiO3 thin film nanogenerator on plastic substrates. Energy harvesting technologies converting external biomechanical energy sources (such as heart beat, blood flow, muscle stretching and animal movements) into electrical energy is recently a highly demanding issue in the materials science community. Herein, we describe procedure suitable for generating and printing a lead-free microstructured BaTiO3 thin film nanogenerator on plastic substrates to overcome limitations appeared in conventional flexible ferroelectric devices. Flexible BaTiO3 thin film nanogenerator was fabricated and the piezoelectric properties and mechanically stability of ferroelectric devices were characterized. From the results, we demonstrate the highly efficient and stable performance of BaTiO3 thin film nanogenerator.

  • PDF

The Effect of Titaniuml Surface Treatment on Osteoblast-Like Cell Attachment and Proliferation (Titanium 표면처리 방법이 Osteoblast-like Cells의부착 및 증식에 미치는 영향)

  • Kim, Do-Yung;Seol, Yang-Jo;Rhyu, In-Cheul;Hahm, Byung-Do;Chung, Chong-Pyoung;Choi, Sang-Mook;Kim, Woo-Jin;Baik, Hong-Koo;Heo, Seong-Joo;Han, Chong-Hyun;Kim, Myung-Ho;Choi, Yong-Chang;Chun, Heoung-Jae;Kwon, Soo-Kyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.3
    • /
    • pp.491-504
    • /
    • 2000
  • In clinical therapy, the current goal of dental implants is to enhance quantity and quality of osseointegration. Surface roughness and oxide structure are considered to influence the behavior of adherent cells. The purpose of this study is to evaluate the effect of different surface treatment on cellular response. The attachment and proliferation of osteoblast-like cell on sandblasted, sandblasted and etched, thermal oxidated surfaces have been compared. Sandblasting was done with $Al_2O_3$ particles(grain size of $50{\mu}m$), etching was processed with $NH_4OH$ : $H_2O_2$ : $H_2O(1:1:5)$ at $90^{\circ}C$ for 1 minute. Thermal oxidation was followed sandblasting and etching at $400^{\circ}C$, $600^{\circ}C$, $800^{\circ}C$ for 2 hours. Measurement of surface roughness after the different treatment did not show any differences of Ra value between terated surfaces. Cell attachment and proliferation were increased during experiment period, but no difference was observed. SEM evaluation revealed a similar pattern of osteoblast-like cells, well attached with dendritic extension and producing numerous matrix vesicles on cell surface. The results of this study showed that oxide layer alteration by thermal oxidation did not affect the attachment and proliferation of osteoblast-like cells. This suggests the possibility that the cellular responses are further influenced by surface roughness than titaniun oxide structure.

  • PDF

The Effect of Acupuncture on the Intestinal Smooth Muscle Dysfunction Caused by Enteric Bacterial Infection in Weaning Piglet (돼지의 세균성 위장관 질환에 따른 평활근 기능 이상에 대한 침술의 효과)

  • Kim, Tae-wan;La, Jun-ho;Sung, Tae-sik;Kang, Jeong-woo;Nam, Tchi-chou;Choi, Min-cheol;Yoon, Yeo-sung;Yang, Il-suk
    • Korean Journal of Veterinary Research
    • /
    • v.43 no.3
    • /
    • pp.415-421
    • /
    • 2003
  • It is now generally accepted that acupuncture is effective in diarrhea caused by bacterial infection. However, its effect on the intestinal smooth muscle dysfunction is not clear. Therefore, we investigated the effect of acupuncture therapy at Jiao-chao (GV-1) on the intestinal muscle dysfunction in weaning piglets orally infected by Escherichia coli. The animals are divided into four groups; 1) E. coli + no-treatment, 2) E. coli + antibiotic, 3) E. coli + acupuncture, 4) normal group. In the three E. coli infected groups, low frequency electrical field stimulation (EFS, 1 Hz) provoked triphasic responses composed of initial relaxation followed by on-contraction and off-contraction. While in the normal group, EFS (1Hz) induced biphasic responses composed of relaxation during the stimulation and off-contraction. At the high frequency (16Hz) EFS, both on-contraction and off-contraction of the E. coli + antibiotic, E. coli + acupuncture and the normal group were larger than those of the E. coli + no-treatment group. In the non-adrenergic non-cholinergic (NANC) condition, only biphasic responses occurred to EFS in all experimental groups and the off-contraction of E. coli + antibiotic, E. coli + acupuncture and the normal group were larger than those of the E. coli + no-treatment group. The response to carbachol of those three groups was also significantly greater than that of the E. coli + no-treatment group. These results suggest that acupuncture is as effective as antibiotic in the dysfunction of colonic circular muscle caused by E. coli infection. The maintenance of contractile neuromuscular transmission seems to be involved in the mechanism of the acupuncture effects on diarrhea.

Effect of Electroacupuncture on Patients with Idiopathic Parkinson's Disease (특발성 파킨슨병 환자의 전침치료 효과)

  • Kang, Mi-kyung;Lee, Sang-hoon;Hong, Jang-moo;Park, Sang-min;Kang, Jung-won;Park, Hi-joon;Lim, Sabina;Chang, Dae-il;Lee, Yun-ho
    • Journal of Acupuncture Research
    • /
    • v.21 no.5
    • /
    • pp.59-68
    • /
    • 2004
  • Objective : This study was designed to evaluate the effect of electroacupuncture with various scales on symptoms of idiopathic Parkinson's disease. Methods : Subjects were voluntarily recruited by newspapers and internet. All the subjects are confirmed as idiopathic parkinson's disease by a neurologist. The acupuncture therapy was performed twice a week for 8 weeks. Acupuncture points for EA group were GB34, and LR3, electrical stimulation frequency was 120Hz, duration 15 minutes, and intensity is up to pain threshold according to patients. The patient's symptoms were assessed before, after 4 weeks and after 8 weeks treatments by unified Parkinson's disease rating scale(UPDRS), modified Hoehn-Yahr(H-Y) stage, Schwab & England activity of daily living and freezing of gait questionnaire(FOGQ). Results : UPDRS I, II, III, IV and total UPDRS scores were significantly improved after 4 weeks(p<0.05) and after 8 weeks(p<0.05) compared to the pre-treatment. The scores of ADL were significantly improved after 4 weeks(p<0.05) and after 8 weeks(p<0.05). There were significant changes in H-Y stage after 4 weeks(p<0.05), but There were no significant changes in H-Y stage after 8 weeks. There were significant changes in FOGQ scale after 4 weeks(p<0.05) and after 8 weeks(p<0.05). Conclusion : This study suggests that electroacupuncutre treatments can be applicable to improve symptoms in the patients with idiopathic Parkinson's disease.

  • PDF