• Title/Summary/Keyword: electrical system

Search Result 32,524, Processing Time 0.056 seconds

Dynamic Equivalents of the KEPCO System for the Stability Analysis

  • Lee, Hanmin;Kwon, Sae-hyuk;Gilsoo Jang;Lee, Byongjun;Byunghun Chang
    • KIEE International Transactions on Power Engineering
    • /
    • v.12A no.1
    • /
    • pp.20-25
    • /
    • 2002
  • This paper deals with the development of dynamic equivalents of the Korea Electric Corporation (KEPCO) systems. Several coherency identification methods are studied in order to find a proper method to well represent the dynamic characteristics of the KEPCO system. Also, this paper presents the comparison of the detail and classical aggregation methods in terms of the dynamic and static characteristics of the system. The nonlinear time simulation of the developed KEPCO equivalent system and the original system is performed to illustrate the validity of the equivalent system.

A Study on the Development of Battery Energy Storage System (전지이용 전력저장장치 기술개발)

  • Hwang, Yong-Ha;Lee, Keun-Seob
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.905-907
    • /
    • 1993
  • Demand for electricity is increasing annually. Especially, the daytime demand grawth shows higher than any other time period. So the big difference between maximum and minimum electrical demand becomes another important problem to be solved. The Battery Energy Storage System is chosen as one of the solutions among the sevral methods. The purpose of utilization of Battery Energy Storage System is to improve the daily load factor. Also, Battery Energy Storage System may be used for the load levelling or the load shifting as well as the spinning reserve. Up to now, only the pumped hydro power plant system has been operated on the commercial basis, but this system has so many constraints such as site, environmental effects, construction period, ect. Being considered current electrical power situation the development of electric storage system is in need latly. Among the various electric storage systems, Battery Energy System is chosen with the top priority because it has sevral merits to cover such as the short construction period, the demand site installation, and the food environmental characteristics.

  • PDF

Key Technologies of Supercapacitor Energy Storage System of IP Transmitter

  • Zeng, Zhihui;Wang, Xiaowei;Wei, Yanfang;Hu, Zhiguo;Yu, Yangxiao;Zhang, Zhigang
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.316-331
    • /
    • 2019
  • A practical application of a supercapacitor energy storage system in a polarization instrument is proposed on the basis of the energy storage requirements of an induced polarization (IP) transmitter for geophysical exploration. We focused on the energy storage system of a supercapacitor, the topology of the power converter, and the system control strategy as key technologies, and we performed theoretical research and experimental tests on the system and developed an experimental platform. The experiments validated the theoretical research on the key technologies of the supercapacitor energy storage system and demonstrated the effectiveness of the innovation. Results showed that the storage system is efficient and satisfies the energy storage needs of the IP transmitter.

Electrical Environmental Effects of Power System (전력설비의 전기환경장해)

  • ;申玖容
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.156-156
    • /
    • 1999
  • This paper describes the characteristics and the criteria of electrical environmental effects produced from power system especially transmission line. Audible noise radio and TV interference, electric and magnetic inductions which are main items for optimal conductor selection as well as major contributors to the community complaint of electrical environmental problem, are surveyed and studied comparing with the criteria or the environmental protection regulation of domestic and foreign countries. As a result a domestic criteria of electrical environmental on power system was suggested.

A Study on the Countermeasure Algorithm for Power System Disturbances in Large Scale Fuel Cell Generation System (대용량 연료전지시스템의 계통외란 방지알고리즘에 관한 연구)

  • Choi, Sung-sik;Kim, Byung-ki;Park, Jae-beom;Rho, Dae-seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.711-717
    • /
    • 2016
  • Recently, fuel cell generation system with high energy efficiency and low CO2 emission is energetically interconnected with distribution power system. Especially, MCFC(molten carbonate fuel cell) operating at high temperature conditions is commercialized and installed as a form of large scale power generation system. However, it is reported that power system disturbances such as harmonic distortion, surge phenomenon, unbalance current, EMI(Electromagnetic Interference), EMC (Electromagnetic Compatibility) and so on, have caused several problems including malfunction of protection device and damage of control devices in the large scale FCGS(Fuel Cell Generation System). Under these circumstances, this paper proposes countermeasure algorithms to prevent power system disturbances based on the modelling of PSCAD/EMTDC and P-SIM software. From the simulation results, it is confirmed that proposed algorithms are useful method for the stable operation of a large scale FCGS.

Generalized Stability Criterion for Multi-module Distributed DC System

  • Liu, Fangcheng;Liu, Jinjun;Zhang, Haodong;Xue, Danhong
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.143-155
    • /
    • 2014
  • The stability issues of a multi-module distributed DC power system without current-sharing loop are analyzed in this study. The physical understanding of the terminal characteristics of each sub-module is focused on. All the modules are divided into two groups based on the different terminal property types, namely, impedance (Z) and admittance (Y) types. The equivalent circuits of each group are established to analyze the stability issues, and the mathematical equations of the equivalent circuits are derived. A generalized criterion for multi-module distributed systems is proposed based on the stability criterion in a cascade system. The proposed criterion is independent of the power flow direction.

Output Characteristics of Peak-Cut Saver System with Energy Storage Device (에너지 저장장치를 갖는 피크컷 세이버 시스템의 출력특성 연구)

  • Seo, Hyou-Uk;Han, D.H;Lee, Y.J;Chun, T.W;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.231-232
    • /
    • 2011
  • It is very important thing to efficiently utilize the solar power. The conventional solar power system has no energy storage device. So the conventional system cannot cut the peak load. In this paper, the solar power system with the energy storage device and the operation algorithm of peak cut function was proposed to cut the peak load. The algorithm principle is proposed based on the insolation curve and load curve. The simulation and experiment was performed to demonstrate the validity of the peak cut algorithm.

  • PDF

Electrical properties and a comparison of W/Cu and WC/Cu contacts (W/Cu 접점과 WC/Cu 접점의 전기적특성과 비교)

  • Lee, Hee-Woong;Pyun, Woo-Pong;Han, Se-Won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1988.05a
    • /
    • pp.43-45
    • /
    • 1988
  • Four W/Cu system(60wt%W-40wt%Cu, -0.lwt%Ni, -0.5wt%Ni, -0.lwt%C) and four WC/Cu system(60wt%WC-40wt%Cu, -0.lwt%Ni, -0.5wt%Ni, 0.lwt%C) electrical contacts were prepared by a press-sinter-infiltration process to compare with their properties. Hardness and electrical conductivity are proportional to the refractory metal(W or WC) properties and showed the effect of additives. Arc erosion trend of switch test is changed by current level. High currant test at 1kA showed a different crack formation pattern and erosion mode between W/Cu system and WC/Cu system contacts.

  • PDF

Thermal Performance Assessment of Wet Ondol and Electric Ondol System (습식온돌시스템과 전기온돌시스템의 열성능 평가)

  • Han, Byung-Jo;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.214-220
    • /
    • 2011
  • This paper studies about the assessment of thermal performance between wet ondol system and electric ondol system. Electrical ondol systems shows faster warm-up time, higher floor surface temperature distribution and lower power consumption than wet ondol system. However, if we provide heat regularly wet ondol system which has more heat capacity shows greater thermal storage than electric ondol system. Therefore, we could conclude that wet ondol system which keeps temperature regularly by the thermal storage show better energy-efficiency in case of using the central heating and district heating system. However, Electrical ondol system shows better efficiency in case of using the space during short time or individual heating systems which needs to heat quickly. The Experiment says that electric ondol system has more benefits on timing to reach the set temperature and energy-efficiency than wet ondol system.

A Study on Improvement of Safety Management of Low Voltage Electrical Equiment (일반용 저압전기설비의 안전등급제 도입에 관한 연구)

  • Jae-Phil Han;Yong-Sung Choi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.598-602
    • /
    • 2023
  • With the purpose of instilling an awareness of the safety of users of electrical equipment and inducing voluntary facility improvement through the safety rating system for general low voltage electrical equipment, simulation and field application of the safety rating of general low voltage electrical equipment were conducted. For the introduction and application of the safety rating system for general low-voltage electrical equipment, data related to domestic safety was investigated and analyzed, cases of introduction in other fields were reviewed, and for design, the 4M risk assessment method of the Korea Occupational Safety and Health Agency and the cases of safety index development in Korea were analyzed and standardized. Safety rating system simulations were conducted for general low-voltage electrical equipment, and problem improvement measures were prepared by analyzing the results through on-site verification and simulation applied to the initial design. Design standards for the introduction of the safety rating system for general low-voltage electrical equipment were prepared, and 394 youth training facilities were applied to the field to see if the design standards were practically applicable to the field. With the application of the safety rating system for low-voltage electrical equipment for general use, youth training facilities that had been classified as 'appropriate' were able to induce an upgrade to a higher level through voluntary facility improvement according to the application of grades (A to E). As a result of inducing voluntary repair projects based on the results of the 1st and 2nd inspection of youth training facilities, it was confirmed that 86 facilities received grade A, 225 facilities received grade B, and only 311 facilities received grade A to B out of a total of 394 facilities, and there was no grade E.