• Title/Summary/Keyword: electrical shock

Search Result 407, Processing Time 0.025 seconds

Study on the Estimation of Long Life Cycle and Reliability Tests for Epoxy Insulation Busway System (에폭시 박막 절연형 버스웨이 시스템의 장기 수명 및 신뢰성 평가에 관한 연구)

  • Jang, Dong-Uk;Park, Seong-Hee;Lee, Kang-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.261-268
    • /
    • 2018
  • The use of electric cable was limited due to the installation time and large space as the increase of power demand and load quantity in side line. In order to solve these problems, the application of busway system which can supply the large current was increasing. But it was lack of methods of performance tests to evaluate the reliability and results of test for busway system. In this paper, we presented items to evaluate the reliability test for epoxy coated busway system with reference to IEC 61349-6. In addition, we proposed items to evaluate the reliability and long term life cycle test for the epoxy coated busway system. The combined acceleration deterioration test that reflects actual conditions of the survey as much as possible was conducted considering both thermal and electrical stresses. The deterioration condition was selected to satisfy fifty years life expectation and the insulation performance verification test of the busway system confirmed the long term life prediction. Furthermore, as test items for reliability assessment of compliance with the environment for the use of temperature, humidity and load current where busway system was installed, thermal overload test, water immersion test, cold shock temperature test and thermal cycle test were performed. And we examined changes in characteristics and abnormality after tests. From results, the test items presented to evaluate performance and reliability of the epoxy insulated busway system were confirmed to be appropriate in this paper, and the performance of the product was also confirmed to be excellent for reliability tests.

Generation of Chemically Active Species in Hybrid Gas-Liquid Discharges (기체-액체 혼합 방전에 의한 화학적 활성종 생성 특성)

  • Chung, Jae-Woo;Locke, Bruce R.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.5
    • /
    • pp.556-563
    • /
    • 2007
  • We carried out a laboratory scale experiment about the characteristics of chemically active species produced in hybrid gas-liquid discharges. The electrode configuration which had high voltage electrode in the gas phase and ground electrode in the liquid was utilized while high voltage electrode has been typically positioned in the liquid in other studies. Our electrode was configured in such a way as to increase the energy efficiency of chemical reactions by creating a higher electrical field strength and a narrower pulse width than the typical electrode configuration. The highest ozone concentration was obtained at 45 kV which was the medium value in operating voltages. The decrease of solution conductivity increased the resistance of liquid phase and the electric field strength through the gas phase, so ozone gene-ration rate was enhanced. The increase of voltage promoted the production rate of hydrogen peroxide by increasing the electric field strength. In a lower voltage, the increase of solution conductivity increased the degradation rate of $H_2O_2$, so the $H_2O_2$ generation rate decreased. On the other hand, the effects of UV radiation, shock waves etc. increased the $H_2O_2$ generation rate as the solution conductivity increased. A higher rate of $H_2O_2$ generation can be achieved by mixing argon to oxygen which generates a stronger and more stable discharges.

An Experimental Study on the Antiepileptic Effects of Cheonmagudeungyeum (천마구등음(天麻鉤藤飮)의 항한질성(抗癎疾性) 효과(效果)에 대한 실험적(實驗的) 연구(硏究))

  • Jeong, Dae-Young;Lee, In;Moon, Byung-Soon
    • The Journal of Internal Korean Medicine
    • /
    • v.18 no.2
    • /
    • pp.65-82
    • /
    • 1997
  • This study has been carried out to investigate the effects of Cheonmagudeungyeum(CGY) extract on anti-convulsive, antipyretic, analgesic, sedative and GABAergic system of experimental animals. The results of this study were as follows : 1. CGY extract prolonged significantly the beginning time to convulsion and death induced by strychnine. 2. CGY extract prolonged significantly the time to death induced by electrical shock of ECT unit(3 sec, 200 F, 25 mA) 3. On the experiment of hypothermic effects of CGY extract on the rectal temperature of mice, CGY extract decreased the rectal temperature of mice. 4. On the experiment of antipyretic effects of CGY extract on the febrile induced by the subcutaneous injection of $150\;{\mu}g/kg$ endotoxin in mice, CGY extract decreased significantly the rectal temperature of mice. 5. On the experiment of analgesic effects of CGY extract on the writhing syndrome induced by intraperitoneal injection 0.7% acetic acid 1 ml/100g in mice, the writhing syndrome induced by acetic acid was reduced significantly by administration of CGY extract. 6. On the experiment of effects of CGY extract on spontaneous motor activity measured by wheel cage method in mice, the spontaneous motor activity was reduced significantly by administration of CGY extract 7. On the experiment of effects of CGY extract on the activity of GABA - transaminase (GABA-T) in mouse brains after 21 days of oral administration of CGY extract, the activity of GABA-T was reduced significantly by administration of CGY extract. 8. On the experiment of effects of CGY extract on the activity concentration of GABA in mouse brain after 21 days of oral administration of CGY extract, the activity concentration of GABA was reduced significantly by administration of CGY extract. 9. On the experiment of effect of CGY water extract on the activity of GAD in mouse brain after 21 days of oral administration of CGY extract, the activity of GAD was reduced significantly by administration of CGY extract. According to the these results, Cheonmagudeungyeum extracts reveal the effects on the anti-convulsive, antipyretic, analgesic, sedative and GABAergic system.

  • PDF

A Study on the Improvement of Welding Method for Ice Evaporator (얼음증발기 용접방법 개선에 관한 연구)

  • Lee, Jeong-Youn;Yoo, Heung-Ryol;Son, Yung-Deug
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.558-564
    • /
    • 2021
  • The water purifier market has increased rapidly in recent years. The welding technology of the evaporator is a key component that determines the level of ice production and the cold water performance of an ice purifier. The finger type evaporator of an ice purifier can remove ice and is divided largely into an instant heat method and a hot gas method. In the hot gas type evaporator, particularly during the production process, the pinhole phenomenon inside the copper pipe and clogging problems occur intermittently when welding high-pressure pipes due to the high-temperature oxygen welding. Its use in a water purifier can cause a problem in that ice and cold water do not form, and repairs cannot be made on site. To solve this problem, in this study, a cap jig was applied to improve the welding defect of the hot gas evaporator. In addition, the oxygen welding flame size was adjusted so that the heat source could be well supplied to the cap jig, and the effectiveness was confirmed through a wave pressure test, a test, and a thermal shock test.

A Case Study of Risk Assessments and Safety Measures in a PCB Manufacturing Process (인쇄회로기판 제조 공정에서 위험성평가와 안전조치 적용 사례 연구)

  • Lee, Young Man;Lee, Inseok
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.120-128
    • /
    • 2022
  • Printed circuit boards (PCBs) are a basic component in the electronics industry and are widely used in nearly all electronic products, such as mobile phones, tablet computers, and digital cameras, as well as in electric equipment. PCB manufacturing involves the use of many chemicals and chemical processes and therefore has more risks than other manufacturing sectors. This study aims to identify the causes of possible accidents during PCB manufacturing through risk assessment, develop and implement safety measures, and evaluate the effectiveness of these measures. Note that the safety measures developed to mitigate the risks of a certain process were also implemented for other similar processes. The risk assessments conducted over seven years, from 2015 to 2021, at a PCB manufacturing company identified 361 hazardous processes. Between 2016 and 2019, 41-56 hazardous processes were identified per year; such processes decreased to fewer than 20 per year after 2020. Application of the risk assessment results to the improvement of the hazardous processes with the similar characteristics seems to be effective in decreasing the risks. Equipment-related factors such as lack of appropriate maintenance, low work standards, and defective protection devices were responsible for 59.8% of all possible accidents. Because PCB manufacturing involves many chemicals, skin contact with hazardous substances, electric shock, fire, and explosion were the most common types of possible accidents (81.7%). In total, 505 safety measures were implemented, including 157 related to purchase and improvement of equipment and devices for safety (31.1%), 147 related to the installation/modification of fire prevention facilities (29.1%), and 69 related to the use of standard electrical appliances (13.7%). Risk assessment conducted after implementing the safety measures showed that these measures significantly decreased risk; 247 processes (68.4%) had a risk level of 3, corresponding to "very low," and 114 processes (31.6%) showed a risk level of 4, corresponding to "low." In particular, risk assessment of 104 processes with risk scores of 12 and 10 other processes with risk score of 16 showed that the risk decreased to 4 after implementing the safety measures. Thus, implementing these measures in similar manufacturing sectors that involve chemical processes can mitigate risk.

Voluntary stand-up physical activity enhances endurance exercise capacity in rats

  • Seo, Dae Yun;Lee, Sung Ryul;Kwak, Hyo-Bum;Seo, Kyo Won;McGregor, Robin A;Yeo, Ji Young;Ko, Tae Hee;Bolorerdene, Saranhuu;Kim, Nari;Ko, Kyung Soo;Rhee, Byoung Doo;Han, Jin
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.20 no.3
    • /
    • pp.287-295
    • /
    • 2016
  • Involuntary physical activity induced by the avoidance of electrical shock leads to improved endurance exercise capacity in animals. However, it remains unknown whether voluntary stand-up physical activity (SPA) without forced simulating factors improves endurance exercise capacity in animals. We examined the effects of SPA on body weight, cardiac function, and endurance exercise capacity for 12 weeks. Twelve male Sprague-Dawley rats (aged 8 weeks, n=6 per group) were randomly assigned to a control group (CON) or a voluntary SPA group. The rats were induced to perform voluntary SPA (lifting a load equal to their body weight), while the food height (18.0 cm) in cages was increased progressively by 3.5 every 4 weeks until it reached 28.5 cm for 12 weeks. The SPA group showed a lower body weight compared to the CON group, but voluntary SPA did not affect the skeletal muscle and heart weights, food intake, and echocardiography results. Although the SPA group showed higher grip strength, running time, and distance compared to the CON group, the level of irisin, corticosterone, genetic expression of mitochondrial biogenesis, and nuclei numbers were not affected. These findings show that voluntary SPA without any forced stimuli in rats can effectively reduce body weight and enhance endurance exercise capacity, suggesting that it may be an important alternative strategy to enhance endurance exercise capacity.

Report for Development of Korean Portable Cardiopulmonary Bypass Machine (한국형 이동식 심폐소생기 개발 보고 I. 실험견을 이용한 개흉식과 폐쇄식 심폐소생술 비교)

  • Kim, Hyoung-Mook;Lee, In-Sung;Baek, Man-Jong;Sun, Kyung;Kim, Kwang-Taik;Kim, Yeon-Soo;Kim, Maeng-Ho;Lee, Hye-Won;Lee, Kyu-Back;Kim, Hark-Jei
    • Journal of Chest Surgery
    • /
    • v.31 no.9
    • /
    • pp.827-836
    • /
    • 1998
  • Background: Effective cardiopulmonary resuscitation (CPR) should provide acceptable hemodynamics for the vital organs during cardiac arrest and early restoration of spontaneous circulation that guarantees long-term, neurologically intact survival. CPR using heart-lung bypass has been suggested as an option for that use. This study was designed to determine the effectiveness of standard CPR techniques, closed-vs. open-chest CPR, which could be used in the future study verifying the role of heart-lung bypass CPR. Material and Method: By using adult mongrel dogs, closed-chest CPR (CCCPR, n=4) and open-chest CPR (OCCPR, n=5) were compared with respects to hemodynamics, restoration of spontaneous circulation(ROSC), and survival. Ventricular fibrillation-cardiac arrest (VF-CA) was induced by electrical shock in all animals. After 4 minutes of cardiac arrest, basic life support (BLS) was applied for 15 minutes and followed by advanced life support (ALS). ALS was maintained until achi ving ROSC but not longer than 30 minutes regardless of the recovery. Resuscitation procedures in either group were standardized by adopting the protocol of American Heart Association. Result: Prearrest baseline hemodynamic data was not different between two groups. During resuscitation, substantially higher systolic pressure was maintained in OCCPR group than in CCCPR group (45$\pm$15 vs. 33$\pm$11 mmHg during BLS, 83$\pm$36 vs. 44$\pm$15 mmHg during ALS; p=NS). Mean pulmonary arterial pressure went up to the level of mean systemic arterial pressures in CCCPR group and to half of that in OCCPR group, and had kept higher in CCCPR group throughout CPR (32$\pm$10 vs. 22$\pm$4 mmHg during BLS and 32$\pm$15 vs. 24$\pm$10 mmHg during ALS; p=NS). ROSC was obtained in 4 of 5 dogs receiving open-chest CPR and 2 of 4 closed-chest CPR. Prolonged survival was noted in all dogs in OCCPR group (6 to 1440 hours) but not in CCPR group (p<.05). Conclusion: These findings indicate that open-chest CPR can be more effective t maintain hemodynamics during cardiac arrest and to obtain restoration of spontaneous circulation and survival. Further experiment will be designed to compare heart-lung bypass CPR with open-chest CPR.

  • PDF