• 제목/요약/키워드: electrical resistivity survey method

검색결과 104건 처리시간 0.021초

전기비저항탐사결과와 터널막장 암반분류의 상관성 검토 (A study on the correlation between the result of electrical resistivity survey and the rock mass classification values determined by the tunnel face mapping)

  • 최재화;조철현;류동우;김학규;서백수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.265-272
    • /
    • 2003
  • In this study, the rock mass classification results from the face mapping and the resistivity inversion data are compared and analyzed for the reliability investigation of the determination of the rock support type based on the surface electrical survey. To get the quantitative correlation, rock engineering indices such as RCR(rock condition rating), N(Rock mass number), Q-system based on RMR(rock mass rating) are calculated. Kriging method as a post processing technique for global optimization is used to improve its resolution. The result of correlation analysis shows that the geological condition estimated from 2D electrical resistivity survey is coincident globally with the trend of rock type except for a few local areas. The correlation between the results of 3D electrical resistivity survey and the rock mass classification turns out to be very high. It can be concluded that 3D electrical resistivity survey is powerful to set up the reliable rock support type.

  • PDF

전기비저항(電氣比抵抗) 탐사(探査)에 의한 포항분지(浦項盆地)와 장기분지의 경계규명(境界糾明) (Investigation of Boundary between Pohang and Janggi Basins by Electrical Resistivity Survey)

  • 민경덕;윤혜수;문희수;이현구;이대하
    • 자원환경지질
    • /
    • 제23권2호
    • /
    • pp.215-219
    • /
    • 1990
  • Geological and electrical resistivity surveys along the survey line of about 3 km between Kyungsangbukdo Youngilgun Hodong and Gwangmyungdong using by dipole-dipole electrode array method were carried out to examine the boundary and structural relationship between Tertiary Pohang and Janggi basins. Electrical resistivity data were interpreted qualitatively and quantitatively by means of pseudosection of apparent electrical resitivity distribution and finite difference method for two dimensional geologic structure model. The nearly vertical fault zone with low electrical resistivity value of 1-5 Ohm-m and widths of about 200m at the surface and 400 m at depth exists around 1.2 km west of national road between Ocheoneup and Yangbukmyun. Mudrocks, sandstones and tuffaceous rocks are widely distributed with electrical resistivity values of 6-77 Ohm-m. Especially, tuffaceous rocks with relatively high electrical resistivity value are predominant at eastern side of fault zone. Consequently, it is known that Pohang and Janggi basins are in fault contact.

  • PDF

변전소 접지설계를 위한 대지저항율 측정시 전극간 최대간격이 접지해석에 미치는 영향 (Effects of Maximum Probe Spacing of Soil Resistivity Survery on Substation Grounding Analysis)

  • 정길조;곽희로;최종기
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권8호
    • /
    • pp.382-386
    • /
    • 2001
  • Presently, typical maximum probe spacing of soil resistivity survey(Wenners 4 pin method) is 20 m in case of 154 K substation grounding design of KEPCO. This paper examined the effects of maximum probe spacing of wenner method on the equivalent soil modeling and the accuracy of grounding resistance measurement by comparing the calculated FOP(Fall-of-Potential) curves of various soil models with the measured one at 154kV H substation. The comparison results showed that the inaccurate estimation of deep soil resistivity, which is caused from the short probe spacing of soil resistivity survey, can produce large errors on measurement of grounding resistance. In this paper a quantitative analysis of FOP at H substation has been presented.

  • PDF

2차원 전기비저항 탐사를 이용한 경주 개곡리 지역의 단층조사 (Investigation of fault in the Kyungju Kaekok-ri area by 2-D Electrical Resistivity Survey)

  • 이치섭;김희준;공영세;이정모;장태우
    • 지구물리와물리탐사
    • /
    • 제4권4호
    • /
    • pp.124-132
    • /
    • 2001
  • 경주 개곡리 지역에서 단층 파쇄대와 지하 내부구조를 파악하기 위해 전기비저항 탐사를 실시하였다. 지층의 전기전도도 분포는 공극수의 함량, 지하수, 공극률 및 점토광물 등의 많은 요인에 의해 지배되고, 이러한 특징은 지층의 풍화상태와 정도, 단층 파쇄대를 간접적으로 설명하는 증거가 된다. 따라서 전기비저항 탐사는 지표에 드러나지 않아 그 연장성이 확실하지 않은 단층 파쇄대를 탐지하기에는 좋은 방법이다. 단층구조를 해석하기 위한 2차원 전기비저항 역산 기법으로 평활화제약 최소자승법을 이용하였고, 모형반응의 계산은 지형의 기복을 고려하기 위해 유한요소법을 사용하였다. 본 연구에 이용된 야외자료는 울산단층에 인접한 경주 외동읍 개곡리 부근의 제 4기 단층 파쇄대로 추정되는 곳에서 쌍극자배열을 이용하여 획득하였다. 이들 자료를 역산하여 전기비저항 2차원 단면도를 작성한 결과, 단층 파쇄대의 특징을 잘 보여주는 것으로 나타났다. 본 연구의 결과, 경주시 외동읍 개곡리 제 4기 단층은 노두에서부터 총 50m까지 단층의 연장이 확인되었으며 그 연장 방향은 $N80^{\circ}W$임이 밝혀졌다. 본 연구를 통해 단층 조사에 있어 2차원 전기비저항 탐사해석이 유용하게 적용될 수 있음을 보여주었다.

  • PDF

물리탐사 결과 복합해석을 통한 방조제 제체 정밀안전진단 사례 (Case History for Safe Diagnosis of Embankment Dike using Composite Analysis of Various Geophysical surveys)

  • 송성호;성백욱;김영규;강미경;이규상;김양빈
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.107-112
    • /
    • 2007
  • To establish the reinforce region and technique through the embankment dike after identifying the region of seawater inflow, we carried out small-loop electromagnetic (EM) survey, electrical resistivity survey and refraction seismic method. We also analyzed the distribution of electrical conductivity in reservoir with depth every two month and monitored water level variations with tidal variation in four observation wells located at seaside and reservoir side in order to analyze the relationship with survey results. From both the cross-correlation between tidal and water level variation at four wells and the distribution of electrical conductivity in reservoir with depth, the major portion of seawater inflow are identified through the embankment dike. From electromagnetic and electrical resistivity survey results, it was found that the seawater inflow were happened through several small regions at seaside and became wider near reservoir side. The 2-D inversion sections of refraction seismic method showed that the pebble-bearing sand layer is spread over the whole region with two to four width. From the this study, small-loop EM, electrical resistivity and refraction seismic surveys accompany with the distribution of electrical conductivity in reservoir with depth and the monitoring results for water level variations are revealed to be effective to identify seawater inflow pathway through embankment dike and to establish the reinforce region and technique through the embankment dike.

  • PDF

옥천대(沃川帶)의 지질(地質) 및 광물자원(鑛物資原)에 관(關)한 연구(硏究) -봉화재 지역(地域)에 대(對)한 전기비저항탐사(電氣比抵抗探査)- (Electrical Resistivity Survey on the Geolgical Structure of the Bonghwajae Area in the Okchon Zone)

  • 민경덕;김창렬;윤춘성;정승환
    • 자원환경지질
    • /
    • 제21권2호
    • /
    • pp.131-137
    • /
    • 1988
  • Geological and electrical resistivity surveys were carried out to investigate subsurface geology and geologic structure of the Bonghwajae area in the Okchon zone. Pseudosections of the apparent electrical resistivity distribution along the three survey lines were obtained by using dipole-dipole electrode array method, and models of subsurface geology and geologic structure by using two dimensional finite difference method. The Bonghwajae fault zone exists around Bonghwajae area in the north-south direction, and is a boundary between Okchon Group and Choson Supper Group. Metabasite and hornblende gabbro intruded along the Bonghwajae fault zone remaining two fracture zones with low resistivity value of 20 ohm-m and widths of about 100m and 70-300m. They strike nearly N-S and dip westward with a high angle of $60-70^{\circ}$. Sochangri fault with a width of about 160m exists between Jisogori and Bonghwajae, by which Bonghwajae fault zone is displaced about 1km in the east-west direction. Hornblende gabbro whose electrical resistivity value is in the range of 5000-8000 ohm-m intruded the metabasite of 2000-4500 ohm-m after the Sochangri fault had formed. Great Limestone Group is widely distributed in the east of Bonghwajae fault zone, and interbeds so called Yongam formation of graphitic black slate with an extremely low electrical resistivity value of 2 ohm-m.

  • PDF

전기비저항탐사결과와 터널막장 암반분류의 상관성 검토 (A study on the Correlation Between the Result of Electrical Resistivity Survey and the Rock Mass Classification Values Determined by the Tunnel Face Mapping)

  • 최재화;조철현;류동우;김훈;오병삼;강문구;서백수
    • 터널과지하공간
    • /
    • 제13권4호
    • /
    • pp.279-286
    • /
    • 2003
  • 최근의 터널설계에 있어서 지보패턴 선정시 전기비저항탐사 결과를 효과적으로 황용하기 위하여 전기비 저항 역산결과와 암반분류와의 상관관계를 도출해 내고자 하는 시도가 이루어지고 있다. 그러나 전기비저항탐사결과를 고려한 예상지보패턴과 실제로 시공된 지보패턴 결과를 비교한 연구는 찾아보기 힘들다. 본 연구에서는 실제 터널굴진 상태에서 막장관찰에 기초한 암반분류 및 지보패턴 선정과 시공 전 수행한 전기비저항 탐사자료를 비교함으로씨 전기비저항 탐사 결과가 어느 정도의 신뢰도로 이용될 수 있는가를 살펴보고자 한다. 전기비저항 자료와 암반분류의 정량적인 상관성을 얻기 위하여 암반분류값으로 RMR(Rock mass rating)을 기본으로, RCR(rock condition rating), N(Rock mass number), Q-system 등을 이용하였다. 전기비저항탐사는 공간적 해상도가 낮기 때문에 후처리 과정으로 크리깅 기법을 사용하여 해상도를 향상시키고자 하였다. 상관도 분석 결과, 2차원 전기비저항탐사결과는 정성적인 경향을 살펴보는데 적합한 것으로 나타났다 3차원 전기비저항탐사 결과와의 상관관계는 매우 높은 것으로 나타나 신뢰도 높은 암반분류에 적용 가능하리라 예상된다.

폐기물 매립지 침출수 조사를 위한 전기비저항 탐사 (An Electrical Resistivity Survey for Leachate Investigation at a Solid Waste Landfill)

  • 이근수;조인기;목종구;김정우
    • 지구물리와물리탐사
    • /
    • 제19권2호
    • /
    • pp.59-66
    • /
    • 2016
  • 환경오염부지의 오염원은 대부분 전기비저항이란 고유물성과 상관관계를 보이기 때문에 전기비저항 탐사는 지중 환경오염조사에 매우 효과적인 방법이다. 이 연구에서는 폐기물 매립장 주변에서 전기비저항 탐사를 수행하여 매립장 주변 지역의 하부 지질구조를 규명하는 한편 침출수 존재 여부 및 영향 범위를 파악하였다. 또한, 주변 관측정의 수질분석 결과와 전기비저항 탐사의 연관성에 대해 분석하였다. 그 결과, 전기비저항 탐사는 수질분석 자료와 매우 높은 연관성을 보였으며, 시추조사 결과와도 상당히 일치하는 것을 확인하였다.

Validation of a new magnetometric survey for mapping 3D subsurface leakage paths

  • Park, DongSoon;Jessop, Mike L.
    • Geosciences Journal
    • /
    • 제22권6호
    • /
    • pp.891-902
    • /
    • 2018
  • Techniques for more reliable detection of 3D subsurface flow paths are highly important for most water-related geotechnical projects. In this case study, a magnetometric resistivity method with a new approach and state-of-the-art technology ("Willowstick survey") was applied to the testbed dam (YD dam) site, and its applicability was validated by geotechnical investigation techniques including borehole drilling and sampling, Lugeon test, flow direction and velocity test, and seismic tomography. In addition to the magnetometric survey, a 3D electrical resistivity survey was performed independently and the results were compared and discussed. The electrical resistivity survey was effective in detecting groundwater levels, but it was limited in mapping leakage paths. On the other hand, the Willowstick magnetometric survey effectively detected geologic weaknesses (e.g., fault fracture) and potential leakage paths of the dam site foundation rocks. The results of this research are expected to be effective for water infrastructures where leakage is an important issue.

전기비저항 및 유도분극 탐사에 의한 저수지 누수지수 산출 (Quantitative Evaluation of Leak Index from Electrical Resistivity and Induced Polarization Surveys in Embankment Dams)

  • 조인기;김연정;송성호
    • 지구물리와물리탐사
    • /
    • 제25권3호
    • /
    • pp.120-128
    • /
    • 2022
  • 국내에는 17,000여개의 저수지가 존재하며, 이중 85% 이상은 50년 이상 경과된 노후 저수지이다. 이들 저수지는 내부침식 및 세굴 현상에 의한 누수와, 그에 따른 붕괴의 위험에 직면하고 있다. 이들 저수지 및 댐의 붕괴를 방지하기 위해서는 누수를 조기에 파악하고 대비하는 것이 중요하다. 전기비저항 탐사는 저수지의 전반적인 상태 파악은 물론 누수의 발달여부 탐지가 가능한 비파괴, 실시간, 현장조사법이다. 이러한 장점 때문에 전기비저항 탐사법은 저수지 안전진단에 널리 사용되고 있다. 그러나 전기비저항 탐사법은 저수지의 안전도에 대한 정량적인 지수를 제공하지 못해 공식적으로 저수지 정밀 안전진단의 상태평가 항목에 포함되어 있지 못하다. 이 연구에서는 전기비저항 탐사와 유도분극 탐사를 통하여 계산된 수분함량에 근거한 정량적 누수지수 산출법을 제시하였다. 특히 일회성 탐사와 모니터링에 의한 정량적 누수지수 산출법을 개발하여 전기비저항 탐사와 유도분극 탐사가 향후 저수지 정밀 안전진단의 상태평가 항목으로 진입할 수 있는 이론적 기반을 제시하였다.