• Title/Summary/Keyword: electrical resistivity dipole-dipole

Search Result 87, Processing Time 0.028 seconds

A Study on Electrical Resistivity Geophysical Surveys of the Noen Landfill Site (전기비저항 탐사를 이용한 노은매립장 침출수 분포에 관한 연구)

  • Kim, Jun-Kyoung;Hong, Sang-Pyo;Kim, Kwang-Yul;Cho, Yong-Jin
    • Journal of Environmental Impact Assessment
    • /
    • v.13 no.5
    • /
    • pp.223-230
    • /
    • 2004
  • The electrical resistivity prospecting method with dipole-dipole array were applied in order to survey 3-D structure characteristics of the Noen landfill site. For the electrical resistivity prospecting, 3 line of measurements were established parallel to the main boundary of the Noen landfill site and additional 2 lines were also established perpendicular to the existing 3 lines for the effective investigation of the landfill site. The results showed that the uppermost layer of the landfill site is believed to be stabilized generally based on the characteristics of electrical resistivity distribution. Lowest layer was partially polluted by the leachate.

Electrical resistivity and seismic reflection mapping for the southeastern part of the Yongdong basin (Cretaceous), Korea (영동분지(백악기) 남동부의 전기비저항 및 탄성파탐사자료 해석)

  • Kim, Ji-Su;Han, Su-Hyeong;Lee, Cheol-U;Kim, Bok-Cheol;Yang, U-Heon;Son, Ho-Ung;Son, Yeong-Gwan
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.2
    • /
    • pp.77-90
    • /
    • 2000
  • Five electrical resistivity dipole-dipole and two seismic reflection surveys were performed in the southeastern margin of the Yongdong basin to delineate the shallow basin architecture. To investigate the intra-basin structure, twenty four resistivity sounding points and three dipole-dipole lines were selected especially in the vicinity of volcanic masses. The basin-fault boundaries are identified in electrical dipole-dipole resistivity section as high resistivity-contrast of approximately $1,500\;{\Omega}{\cdot}m$, characterized as a band of high standard-deviation. They are also effectively clarified in the seismic reflection data: amplitude and continuity contrasts in the common shot gather, first-arrival profiles, complex attribute plots. The intra-basin resistivity structures are constructed by interpolating vertical electrical sounding data and dipole-dipole profiles. The high-resistivity anomalies most likely originate from the northsouth-trending and northeast-dipping volcanic masses, which are to be further quantitatively investigated with geomagnetic and magnetotelluric surveys.

  • PDF

A STUDY ON THE ROLL-ALONG TECHNIQUE USED IN 2D ELECTRICAL RESISTIVITY SURVEYS (2차원 전기비저항 탐사에 사용되는 ROLL-ALONG 기법에 대한 고찰)

  • WonSeokHan;JongRyeolYoon
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.3
    • /
    • pp.155-164
    • /
    • 2003
  • The validity and efficiency of the roll-along technique widely used in 2-D electrical resistivity survey are analyzed in case of the dipole-dipole and the Wenner-Schlumberger arrays by numerical modelling. The shallow anomalous resistivity bodies are successfully inverted both in the dipole-dipole and in the Wenner-Schlumberger arrays because the shallow data of pseudosection are not omitted by the roll-along technique. However, the deep anomalous resistivity bodies can not be well resolved due to the skip of observed data which is more significant in the Wenner-Schlumberger array having relatively poor horizontal coverage of obtaining data. Carrying out electrical survey adopting the dipole-dipole array, the skip of data is insignificant because it is unfeasible to expand the electrodes to the maximum electrode separation coefficient($n_max$) owing to low S/N ratio. In case of the Wenner-Schlumberger array, however, because it is generally feasible to expand the electrodes $n_max$ to the owing to high S/N ratio, it is highly possible that skip of data from the roll-along technique causes significant distortion of inversion results. Therefore, adopting the Wenner-Schlumberger array having deeper median depth(Edwards, 1977) than do the dipole-dipole array on condition of the same unit electrode spacing( ($a$) ) and $n_max$, it is recommended to determine $a$ based on not $n_max$but $n_prob$free from the skip of observing data and forward electrodes with keeping overlap interval 3/4 of the survey line length in order to reduce the distortion of resistivity structure and perform resistivity survey efficiently. These results are confirmed by numerical modelling.

  • PDF

Dipole-Dipole Array Geoelectric Survey for Gracture Zone Detection (전기비저항 탐사법을 이용한 지하 천부 파쇄대 조사)

  • Kim, Geon Yeong;Lee, Jeong Mo;Jang, Tae U
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.3
    • /
    • pp.217-224
    • /
    • 1999
  • Although faults can be found by geological surveys, the surface traces of faults are not easily discovered by traditional geological surveys due to alluvia. In and around faults and fracture zones, the electrical resistivity appears to be lower than that of the surroundings due to the content of groundwater and clay minerals. Therefore, electrical resistivity surveys are effective to search buried faults and fracture zones. The dipole-dipole array electrical resistivity surveys, which could show the two dimensional subsurface electrical resistivity structure, were carried out in two areas, Yongdang-ri, Woongsang-eup, Yangsan-si, Kyungsangnam-do and Malbang-ri, Woedong-eup, Kyungju-si, Kyungsangpook-do. The one was next to the Dongrae Fault and the other near the Ulsan Fault was close to the region in which debatable quaternary fault traces had been found recently. From each measured data set, the electrical resistivity cross-section was obtained using the inversion program the reliability of which was analyzed using analytic solutions. A low resistivity zone was found in the inverted cross-section from the Yongdang-ri area survey data, and two low resistivity zones were found in that from the Malbang-ri area survey data. They were almost vertical and were 15∼20 m wide. Accounting the shape and the very low resistivity values of those zones (<100 Ωm)in the inverted section, they were interpreted as fracture zones although they should be proven by trenching. The reliability of the interpretation might be improved by adding some more parallel resistivity survey lines and interpreting the results in 3 and/or adding other geophysical survey.

  • PDF

Delineation of water seepage in earth-fill embankments by electrical resistivity method (전기비저항탐사에 의한 제당의 누수구간 탐지)

  • 정승환;김정호;양재만;한규언;김영웅
    • The Journal of Engineering Geology
    • /
    • v.2 no.1
    • /
    • pp.47-57
    • /
    • 1992
  • Geophysical methods applied to water seepage problem in earth-fill embankment attempt to detect and map the estimate of size and depth of the seepage path. Seepage zones generally produce lOW resistivity anomalies due to high saturation of water. Dipole-dipole resistivity surveying technique, which is actually a combined sounding-profiling procedure, was used to delineate the seepage path through this study. In this study, the finite difference methods to solve the electric potential distribution in 2 112 dimension, was adopted as the numerical scheme for the forward problem. Second order Marquart's method, one the iterative damped least square methods, was selected for the automatic inversion. The computer program was implemented in FORTRAN 77 for 1 6-bit personal computer. In this paper, we present a case history which illustrates the application of dipole-dipole resistivity method to the delineation of water flow in earth-fill structures. Also the automatic two-dimensional resistivity inversion was applied to a field data where the interpretive advantages of the program become evident.

  • PDF

A Study on the Modified Electrode Arrays in Two-Dimensional Resistivity Survey (2차원 전기비저항 탐사를 위한 변형된 전극배열법에 관한 연구)

  • Kim Jung-Ho;Yi Myeong-Jong;Song Yoonho;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.3
    • /
    • pp.59-69
    • /
    • 2001
  • Five kinds of modified electrode arrays were proposed to overcome the weak points of the commonly used arrays using dipole and/or pole in two-dimensional resistivity surveys. The modified pole-pole array was suggested to overcome the inefficiency caused by distant earthing in pole-pole array. Four kinds of modified arrays using dipole were designed to enhance the signal-to-noise ratio of the conventional dipole-dipole and pole-dipole arrays through boosting up the measured potential difference. In the numerical experiments using the two-dimensional modeling and inversion, the effects of the ambient electrical noise and the resolving power were examined and the results showed the validity of the modified arrays proposed in this study.

  • PDF

Investigation of Contaminated Waste Disposal Site Using Electrical Resistivity Imaging Technique (폐기물 처분장 오염지반조사를 위한 전기비저항 영상화 기법의 적용)

  • Jung Yunmoon;Woo Ik;Kim Jungho;Cho Seongjun
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.1
    • /
    • pp.57-63
    • /
    • 1998
  • The electrical resistivity method, one of old and widely used geophysical prospecting methods, has extended its scope to civil & environmental engineering areas. The electrical resistivity imaging technique was performed at the waste disposal site located in Junju to verify the applicability to the environmental engineering area. The dipole-dipole array, with the dipole spacing of 10 m, was applied along eight survey lines. The field data were obtained under the control of automatic acquisition softwares and topographic effects were corrected during processing stage. The processed resistivity images show that very low resistivity develops inside the disposal site and the distribution of low resistivity is exactly in accord with the boundary of the site except the river side. The depth of low resistivity zones is deeper toward the river side, which is interpreted that there is a high possibility for contaminants to be scattered to the river. From resistivity images, it was feasible to deduce the depth of waste disposal as well as the horizontal/vertical distribution of the contaminated zone, which proved the applicability of the electrical resistivity imaging technique to the environmental engineering area.

  • PDF

Application of resistivity monitoring to examine the grouting effect

  • Farooq, Muhammad;Park, Sam-Gyu;Kim, Jung-Ho;Song, Young-Soo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.79-82
    • /
    • 2006
  • This paper presents to examine the ability of an electrical resistivity method to monitor the grouting effect at subsidence area. To monitor the changes in ground resistivity before and during the grout, series of electrical resistivity monitoring surveys have been conducted. Data has acquired in the form of grid making nine lines parallel to road and four lines traverse the road. Two kinds of electrode arrays modify pole-pole and dipole-dipole arrays were used during resistivity data acquisition. In this paper, the results show that electrical prospecting is an effective method to detect low resistivity imaging zone by grout during the ground reinforcement.

  • PDF

Electrical Resistivity Imaging for Upper Layer of Shield TBM Tunnel Ceiling (쉴드 TBM터널 상부 지반 연약대 전기탐사)

  • Jung, Hyun-Key;Park, Chul-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.401-408
    • /
    • 2005
  • Recently shield TBM tunnellings are being applied to subway construction in Korean cities. Generally these kinds of tunnellings have the problems in the stability of ground such as subsidence because urban subway is constructed in the shallow depth. A sinkhole occurred on the road just above the tunnel during tunneling in Kwangju, so a survey for upper layer of the tunnel was needed. But conventional Ground Probing Radar can't be applicable due to the presence of steel-mesh screen in the shield segment, so no existent geophysical method is applicable in this site. Because the outer surface of each shield segment is electrically insulated, dipole-dipole resistivity method which is popular in engineering site investigation, was tried to this survey for the first time. Specially manufactured flexible ring-type electrodes were installed into the grouting holes at an interval of 2.4 m on the ceiling. The K-Ohm II system which has been developed by KIGAM and tested successfully in many sites, was used in this site. The system consists of 1000Volt-1Ampere constant-current transmitter, optically isolated 24 bit sigma-delta A/D conversion receiver - maximum 12 channel simultaneous measurements, and graphical automatic acquisition software for easy data quality check in real time. Borehole camera logging with circular white LED lighting was also done to investigate the state of the layer. Measured resistivity data lack of some stations due to failing opening lids of holes, shows general high-low trend well. The dipole-dipole resistivity inversion results discriminate (1) one approximately 4 meter diameter cavity (grouted but incompletely hardened, so low resistivity - less than $30{\Omega}m$), (2) weak zone (100-200${\Omega}m$), and (3) hard zone (high resistivity - more than 1000${\Omega}m$) very well for the distance of 320 meters. The 2-D inversion neglects slight absolute 3-D effect, but we can get satisfactory and useful information. Acquired resistivity section and video tapes by borehole camera logging will be reserved and reused if some problem occurs in this site in the future.

  • PDF

Resistivity Protecting analysis due to test survey result (시험탐사 결과에 따른 전기비저항 탐사 분석)

  • Kim, Jae-Hong;Hong, Won-Pho;Park, Chul-Sook;Im, En-Sang
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1285-1289
    • /
    • 2008
  • Increasing the flood control capacity's link that is enforcing to existing dam by unusual change of weather, While build planing construction by exiting spillway of tunnel type to dam, could know that part bed rock is formed as is different with design. Grasped topography of research area and geology state to definite distribution aspect of different bed rock, Place that achieved Surface geological Survey and correct Survey is difficult in some section enforced Electrical resistivity dipole-dipole investigation. Grasped stratigraphy distribution confirmation and fracture or weathering zone making out siding 2D-Resistivity Electrical resistivity diagram and Reverse analysis diagram, examining closely soil weathered rock rock's distribution state, established stability countermeasure plan