• Title/Summary/Keyword: electrical parameters.

Search Result 5,745, Processing Time 0.214 seconds

Relationship between the Initial Clamping Force and the Position of Supporter in the Wedge Type Rail Clamp (쐐기형 레일클램프에서 초기압착력과 지지대의 위치사이의 관계)

  • Lee, Seong-Wook;Han, Geun-Jo;Lee, Kwon-Soon;Han, Dong-Seop
    • Journal of Navigation and Port Research
    • /
    • v.31 no.1 s.117
    • /
    • pp.65-70
    • /
    • 2007
  • The wedge type rail clamp compresses with small clamping force at first, and with large clamping force when the wind speed increases bemuse of the wedge working. At this time in order to display the wedge working, the rail clamp slips along a rail. If the supporter is not installed in the rail clamp when the wind speed increases more and more, the structure will occur overload which leads the structure to fracture. So the supporter has to be installed in the rail clamp. The proper position of this supporter is determined by the initial clamping force and the wege angle. Therefore in this study we adopted 5-kinds of wedge angle as the design parameters, and carried out the finite element analysis, in order to analyze the relationship between the initial clamping force and the position of supporter in the wedge type rail clamp.

System Development of a 100 kW Molten Carbonate Fuel Cell III (System Control and Operation Mode) (100 kW급 용융탄산염 연료전지 시스템 개발 III (시스템 제어 및 운전모드))

  • Lim, Hee-Chun;Ahn, Kyo-Sang;Seo, Hai-Kyung;Eom, Yeong-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1350-1352
    • /
    • 2003
  • For developing a 100 kW MCFC power generation system, Several design parameters for a fuel cell stack and system analysis results by Cycle Tempo, a processing computer soft ware, were described. Approximately two substacks with 90 cells are required to generate 100 kW at a current density of $125\;mA/cm^2$ with $6000\;cm^2$ of cells. An overall heat balance was calculated to predict exit temperature. The 100 kW power is expected only under pressurized operation condition at 3 atm. Recycle of cathode gas by more than 50% is recommended to run the stack at $125\;mA/cm^2$ and 3 atm. Manifolds should be designed based on gas flow rates for the suggested operating condition. The fuel cell power generation system was designed conceptually with several choices of utilization of anode exhaust gas. To operate and evaluate the MCFC system, control and measurement system and operation mode are designed before 100 MCFC system construction. In system control schematics, OS, PLC and MMI were consisted and have roles for MCFC system control. For operation of 100 kW MCFC system, NS, PS PR mode were considerated step by step and simulated.

  • PDF

Influence of hydraulic retention time on biogas production during leachate treatment

  • Baati, Souaad;Benyoucef, Fatima;Makan, Abdelhadi;El Bouadili, Abdelaziz;El Ghmari, Abderrahmene
    • Environmental Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.288-293
    • /
    • 2018
  • The main objective of this study is to investigate the influence of hydraulic retention time (HRT) on biogas production during leachate treatment using an anaerobic reactor type Upflow Anaerobic Sludge Blanket. For this purpose, four HRTs ranging from 12 to 48 h were experienced. The obtained results showed that higher amount of biogas could be produced during longer HRTs. However, HRTs longer than 48 h could not affect clearly the biogas generation and considered as unnecessary given the small additional amount of biogas produced during the degradation process. A volume of $0.434L/L_{leachate}/d$ was achieved during the treatment with a HRT of 48 h. The higher biogas production, the smaller chemical oxygen demand (COD) values achieved. Besides, COD removal and biogas production positively correlate, showing that the active biomass has degraded effectively the organic load to produce biogas. Moreover, all the analyzed physicochemical parameters have experienced a decrease after 48 h except for the pH, which increased to approximately neutral value. More precisely, a decrease of 93.8%, 89.7%, 95%, 70%, 77%, and 84.4% was recorded for COD, electrical conductivity, total suspended solid, turbidity, $NH_4{^+}-N$, and $NO_3{^-}-N$, respectively.

Determination of Effective Relay Candidates for the Best Relay Selection in Wireless Systems in the Presence of Interference (간섭이 존재하는 무선 시스템에서 최적의 중계 노드 선택을 위한 효과적인 중계 노드 후보 결정 방법 연구)

  • Lee, In-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.12
    • /
    • pp.2812-2817
    • /
    • 2013
  • In this paper, an outage probability for the best relay selection in decode-and-forward relaying systems in the presence of interference is analyzed over Rayleigh fading channels. Based on the outage performance results, we propose a method to determine effective relay candidates for the best relay selection, where the effective relay candidates represent the relays except for relays that make no contribution to improving the performance. in all possible relays given in the system. By determining the effective relay candidates, the feedback overhead of channel state information and the energy consumption of relays can be significantly reduced while minimizing the performance degradation. In this paper, we provide important parameters that affect the determination of the effective relay candidates.

PWM Inverter System Control for Flywheel Energy Storage System using PDFF(Pseudo-Derivative Control with Feedforward Gain) Algorithm (PDFF 기법을 적용한 플라이휠 에너지 저장장치용 PWM 인버터 시스템 제어)

  • Park, Jong-Chan;Jeong, Byung-Hwan;Choi, Hee-Ryong;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.267-275
    • /
    • 2007
  • This paper presents about energy input and output modeling for a flywheel energy storage system that can store and supply mechanical energy, which is emerging as one of clean energy sources, and the analysis and control of a PWM inverter system. Moreover, this paper describes flywheel's characteristics related to variations of mechanical and electrical parameters like as voltage and current versus speed characteristics formed as numerical formula and thus simulate behaviour-status of flywheel energy. Also for comparison and analysis between PI control and PDFF control, the modeling, design and analysis to the single-phase full bridge inverter with double loop feedback control is accomplished through numerical description and simulation. Finally, under load condition 0.1[pu], 1[pu]. it is validated that harmonic characteristics for voltage and current wave is controlled within 5% below even dynamics condition.

Line Impedance Estimation Based Adaptive Droop Control Method for Parallel Inverters

  • Le, Phuong Minh;Pham, Xuan Hoa Thi;Nguyen, Huy Minh;Hoang, Duc Duy Vo;Nguyen, Tuyen Dinh;Vo, Dieu Ngoc
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.234-250
    • /
    • 2018
  • This paper presents a new load sharing control for use between paralleled three-phase inverters in an islanded microgrid based on the online line impedance estimation by the use of a Kalman filter. In this study, the mismatch of power sharing when the line impedance changes due to temperature, frequency, significant differences in line parameters and the requirements of the Plug-and-Play mode for inverters connected to a microgrid has been solved. In addition, this paper also presents a new droop control method working with the line impedance that is different from the traditional droop algorithm when the line impedance is assumed to be pure resistance or pure inductance. In this paper, the line impedance estimation for parallel inverters uses the minimum square method combined with a Kalman filter. In addition, the secondary control loops are designed to restore the voltage amplitude and frequency of a microgrid by using a combined nominal value SOGI-PLL with a generalized integral block and phase lock loop to monitor the exact voltage magnitude and frequency phase at the PCC. A control model has been simulated in Matlab/Simulink with three voltage source inverters connected in parallel for different ratios of power sharing. The simulation results demonstrate the accuracy of the proposed control method.

A Study on the Characteristics of Si-$SiO_2$ interface in Short channel SONOSFET Nonvolatile Memories (Short channel SONOSFET 비휘발성 기억소자의 Si-$SiO_2$ 계면특성에 관한 연구)

  • Kim, Hwa-Mok;Yi, Sang-Bae;Seo, Kwang-Yell;Kang, Chang-Su
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1268-1270
    • /
    • 1993
  • In this study, the characteristics of Si-$SiO_2$ interface and its degradation in short channel SONOSFET nonvolatile memory devices, fabricated by 1Mbit CMOS process($1.2{\mu}m$ design rule), with $65{\AA}$ blocking oxide layer, $205{\AA}$ nitride layer, and $30{\AA}$ tunneling oxide layer on the silicon wafer were investigated using the charge pumping method. For investigating the Si-$SiO_2$ interface characteristics before and after write/erase cycling, charge pumping current characteristics with frequencies, write/erase cycles, as a parameters, were measured. As a result, average Si-$SiO_2$ interface trap density and mean value of capture cross section were determined to be $1.203{\times}10^{11}cm^{-2}eV^{-1}\;and\;2.091{\times}10^{16}cm^2$ before write/erase cycling, respectively. After cycling, when the write/erase cycles are $10^4$, average $Si-SiO_2$ interface trap density was $1.901{\times}10^{11}cm^{-2}eV^{-1}$. Incresing write/erase cycles beyond about $10^4$, Si-$SiO_2$ interface characteristics with write/erase cycles was increased logarithmically.

  • PDF

Parameter Evaluation of High-Power Pulse Transformer for L-Band 30-MW Klystron (L-band 30-MW 클라이스트론용 고출력 펄스트랜스포머의 파라미터 평가)

  • Jang, S.D.;Son, Y.G.;Kwon, S.J.;Oh, J.S.;Kim, S.H.;Yang, H.R.;Moon, S.I.;Kwon, B.H.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1079-1081
    • /
    • 2007
  • An L-band Linear Accelerator System for E-beam sterilization is under construction for bio-technology application. The klystron-modulator system as an RF microwave source has an important role as major components to offer the system reliability for long time steady-state operations. A PFN line type pulse generator with a peak power of 71.5-MW, $7\;{\mu}s$, 285 pps is required to drive a high-power klystron. The high power pulse transformer has a function of transferring pulse energy from a pulsed power source to a high power load. The pulse transformer producing a pulse with a peak voltage of 275 kV is required to produce 30-MW peak and 60 kW average RF output power at the frequency of 1.3-GHz. We have designed the high power pulse transformer with 1:13 step-up ratio. The peak and average power capability is 71.5-MW (275 kV, 260 A at load side with $7\;{\mu}s$ pulse width) and 130 kW, respectively. In this paper, we present measurements and its analysis on the design parameters, and an initial test result as well as a design concept on the high-power pulse transformer.

  • PDF

Magnetic Properties of $GdBa_2Cu_3O_{7-y}$ Bulk Superconductors Fabricated by a Top-seeded Melt Growth Process (종자 결정 성장법으로 제조된 $GdBa_2Cu_3O_{7-y}$ 벌크 초전도체의 자기적 특성)

  • Kim, K.M.;Park, S.D.;Jun, B.H.;Ko, T.K.;Kim, C.J.
    • Progress in Superconductivity
    • /
    • v.14 no.1
    • /
    • pp.39-44
    • /
    • 2012
  • The fabrications condition and superconducting properties of top-seeded melt growth (TSMG) processed $GdBa_2Cu_3O_{7-y}$ (Gd123) bulk superconductors were studied. Processing parameters (a maximum temperature ($T_{max}$), a temperature for crystal growth ($T_G$) and a cooling rate ($R_G$) through a peritectic temperature ($T_P$) for the fabrication of single grain Gd123 superconductors were optimized. The magnetic levitation forces, trapped magnetic fields, superconducting transition temperature ($T_c$) and critical current density ($J_c$) of the Gd123 bulks superconductors were estimated. Single grain Gd123 bulk superconductors were successfully fabricated at the optimized processing condition. The $T_c$ of a TSMG processed Gd123 sample was 92.5 K and the $J_c$ at 77 K and 0 T was approximately $50kA/cm^2$. The trapped magnetic field contour and magnetic levitation forces were dependent on the top surface morphology of TSMG processed Gd123 samples. The single grain Gd123 samples, field-cooled at 77 K using a Nd-B-Fe permanent magnet with 5.27 kG and 30 mm dia., showed the trapped magnetic field contour of a single grain with a maximum of 4 kG at the sample center. The maximum magnetic levitation forces of the single grain Gd123 sample, field-cooled or zero field-cooled, were 40 N and 107 N, respectively.

The degradation phenomena in SiGe hetero-junction bipolar transistors induced by bias stress (바이어스 스트레스에 의한 실리콘-게르마늄 이종접합 바이폴라 트랜지스터의 열화 현상)

  • Lee, Seung-Yun;Yu, Byoung-Gon
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.229-237
    • /
    • 2005
  • The degradation phenomena in SiGe hetero-junction bipolar transistors(SiGe HBTs) induced by bias stress are investigated in this review. If SiGe HBTs are stressed over a specific time interval, the device parameters deviate from their nominal values due to the internal changes in the devices. Reverse-bias stress on emitter-base(EB) junctions causes base current increase and current gain decrease because carriers accelerated by the electrical field generate recombination centers. When forward-bias current stress is conducted at an ambient temperature above $140^{\circ}C$ , hot carriers produced by Auger recombination or avalanche multiplication induce current gain fluctuation. Mixed-mode stressing, where high emitter current and high collector-base voltage are simultaneously applied to the device, provokes base current rise as EB reverse-bias stressing does.