특수건물의 화재현황 및 분석

  • 박창복;김인태
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1996년도 학술발표회
    • /
    • pp.10-14
    • /
    • 1996
  • Followings are the analysis of 578 fire accidents occurred at Specific Building In 1995. Fire frequency had been slightly decresed since 1992. In regional, fire accidents in Seoul and Ulsan were higher than the average. Occupational fire frequency order was apartment, factory, buildings over six stories and market place. In addition, the order of life loss was buildings over six stories, apartment and factory. And property loss totaled six times higher than that of Fire Department. Among the causes of fire, electrical fire formed 44.8%, from which we can assume that there were some problems in the investigation of fire causes.

  • PDF

아산화동증식 발열에 의한 화재 사례의 분석 (Analysis of a Fire Case Caused by Heat Generation due to Cu2O Breeding)

  • 박진영;이의평
    • 한국화재소방학회논문지
    • /
    • 제34권2호
    • /
    • pp.54-63
    • /
    • 2020
  • 전선 접속부 등에서 아산화동(Cu2O)증식 발열에 의해 화재가 발생하는 것은 화재조사 전문가들에게 널리 알려져 있지만 아산화동증식 발열에 의한 화재사례를 구체적으로 분석하여 소개하는 논문은 거의 없다. 이 논문에서는 전기적인 접속부분의 발열에 의한 화재 통계와 아산화동증식 발열 현상과 특징을 분석한 후 아산화동증식 발열에 의해 대학실험실의 전선 접속부분에서 화재가 발생한 사례에 대해 구체적으로 분석하고 있다. 이 화재사례는 발화개소의 화재패턴 조사, 전선 접속부분에 대한 육안 조사, 3차원 CT 촬영 조사, 전원인가 시험, 실체현미경 조사, SEM과 EDS 분석을 통해서 전선 접속부분에서 아산화동 증식 발열로 인해 화재가 발생한 것으로 결론을 내릴 수 있었다.

옥외에 설치한 계기용변성기의 화재원인 분석과 판정 (The Fire Cause Analysis and Judgement of Metering Out Fit(MOF) Installed Outdoors)

  • 송길목;김영석;김선구
    • 한국화재조사학회지
    • /
    • 제11권1호
    • /
    • pp.75-90
    • /
    • 2007
  • 본 논문에서는 국내에서 옥외에 설치한 계기용변성기의 화재원인을 분석한 것이다. 이는 KSC IEC와 같은 공인된 규정에 의해 준수되었고, 현장에서 입증이 가능하도록 전개되었다. 결과적으로, 공정의 마무리가 불량한 계기용변성기의 개스킷 부분에서 화재 원인을 찾아내었다. 화재 과정을 추정하면, 미체결 개스킷에 기인한 계기용변성기에 수분이 침투한 것이다.

  • PDF

산불에 노출된 가공송전선의 기계적 및 전기적 특성 거동 (Mechanical and Electrical Properties of Overhead Conductor due to Forest Fire)

  • 김병걸;장용호;김상수;한세원
    • 한국전기전자재료학회논문지
    • /
    • 제21권11호
    • /
    • pp.1042-1048
    • /
    • 2008
  • Forest Fire can cause a serious damage to overhead conductors. Therefore, the detailed investigation for the changes of mechanical and electrical properties of damaged conductors should be carried out to understand the effect of forest fires on conductors. This is very much important to maintain transmission line safely. Especially, this paper describes the changes of mechanical and electrical properties of flame exposed conductor. Overhead conductors temperature were almostly 55$\sim$65% of ambient temperature. Tensile Strength decreased according to incerase of Forest Fire temperature. The detailed will be given in the text.

저압 배선선로의 과전류 사고시 전기화재분석에 관한 연구 (A Study on the Electrical fire Analysis in Overcurrent of Low Voltage Wiring)

  • 이상호;오홍석
    • 조명전기설비학회논문지
    • /
    • 제18권3호
    • /
    • pp.142-148
    • /
    • 2004
  • 최근 전자계-열계 해석 소프트웨어의 발전에 힘입어 전자계-열계 해석 이론을 바탕으로 컴퓨터 시뮬레이션에 의한 전기화재의 정확한 원인분석과 조사가 체계적으로 연구되고 있으나, 매우 미흡한 실정이다. 따라서 본 논문에서는 비닐 평형 코드(600 V, VFF, $2C{\times}$1.25mm^2)을 모델로 하여 과전류시 전류크기에 따른 전선의 온도분포 및 이격거리에 따른 도체 상호간의 힘을 컴퓨터 시뮬레이션(Flux2D)을 통하여 계산하며, 또한 직접 제작한 대전류 공급장치(형명 : EHT_EFAD, Korea)을 사용하여 과전류시 전류크기와 공급시간에 따른 도체 상호간의 이격거리에 대하여 실험함으로써 과전류로 인한 전기화재 원인분석 방법에 대하여 제안하고자 한다.

퍼지추론을 이용한 지식기반 전기화재 원인진단시스템 (A Knowledge-based Electrical Fire Cause Diagnosis System using Fuzzy Reasoning)

  • 이종호;김두현
    • 한국안전학회지
    • /
    • 제21권3호
    • /
    • pp.16-21
    • /
    • 2006
  • This paper presents a knowledge-based electrical fire cause diagnosis system using the fuzzy reasoning. The cause diagnosis of electrical fires may be approached either by studying electric facilities or by investigating cause using precision instruments at the fire site. However, cause diagnosis methods for electrical fires haven't been systematized yet. The system focused on database(DB) construction and cause diagnosis can diagnose the causes of electrical fires easily and efficiently. The cause diagnosis system for the electrical fire was implemented with entity-relational DB systems using Access 2000, one of DB development tools. Visual Basic is used as a DB building tool. The inference to confirm fire causes is conducted on the knowledge-based by combined approach of a case-based and a rule-based reasoning. A case-based cause diagnosis is designed to match the newly occurred fire case with the past fire cases stored in a DB by a kind of pattern recognition. The rule-based cause diagnosis includes intelligent objects having fuzzy attributes and rules, and is used for handling knowledge about cause reasoning. A rule-based using a fuzzy reasoning has been adopted. To infer the results from fire signs, a fuzzy operation of Yager sum was adopted. The reasoning is conducted on the rule-based reasoning that a rule-based DB system built with many rules derived from the existing diagnosis methods and the expertise in fire investigation. The cause diagnosis system proposes the causes obtained from the diagnosis process and showed possibility of electrical fire causes.

차단기의 표면에서 절연파괴에 의한 전기적 특이점에 관한 연구 (A Study on the Electrical Unique point due to the Dielectric breakdown at the Surface of a Circuit Breaker)

  • 김동욱;김만건;김명수;김혁수
    • 한국화재조사학회학술대회
    • /
    • 한국화재조사학회 2011년도 제20회 추계학술대회
    • /
    • pp.239-248
    • /
    • 2010
  • 2008년도 사고설비별 전기화재 발생현황을 살펴보면 전기화재중 전기배선 및 배선기구에서 발화한 화재가 2,540건으로 전기화재 발생 중 25.95 %를 점유하였다. 또한 사고전압별 전기화재 발생현황으로 220/380 V에서 화재가 6,320건(64.4 %)으로 전기화재의 대부분을 점유하였다. 전기화재는 단락, 과전류, 접촉불량, 트래킹 등 9가지로 분류할 수 있다. 이러한 전기로부터 재해를 막기 위하여 누전차단기나 배선용차단기를 사용하여 일부의 전기화재 원인을 차단할 수 있으나 차단기 자체에서 발생하는 원인에 대하여는 보호할 전기기기가 부재하다. 본 논문에서는 최근 실화법의 적용으로 일반적으로 전기화재로 취급되어지지만 보다 세밀히 조사하면 제조결함, 사용자 부주의, 설치 및 환경에 따른 위험성을 분석하고 전기설비에서의 화재 발생에 대한 예방대책에 활용할 수 있도록 연구하였다.

  • PDF

차량 전장부품 손상으로 인한 차량화재 사고사례 분석 (Analysis on the Fire Accident of Vehicle Due to Damage of the Vehicle's Electrical Components)

  • 박남규;김진표;남정우;사승훈;송재용
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.32-38
    • /
    • 2015
  • In this paper, we analyzed the vehicle fire accidents due to damage of vehicle's electrical components, which is applied to a vehicle. In recent development of electrical components technology, approximately 40% of vehicle manufacturing parts have applied electronic circuit technology. Phenomenon such deterioration of insulating performance or electric breakdown on the vehicle's electrical components and printed circuit boards(PCBs) resulted from moisture, contamination and aging due to repetitive operations, lead to the vehicle fire. Therefore, the application of electrical components with adequate electric capacity for vehicle and usage of molding techniques using a non-combustible materials to shut off the oxygen should be applied in order to prevent vehicle fire due to damage of the electrical components and PCBs.

과학적 방법을 적용한 화재조사와 결함수 분석을 이용한 정온전선의 발화원인 추론 (Fire Cause Reasoning of Self-regulating Heating Cable by a Fire Investigation Applying the Scientific Method and Fault Tree Analysis)

  • 김두현;이흥수
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.73-81
    • /
    • 2016
  • 정온전선은 평형 도체 사이에 반도전성 폴리머를 연속 압출 방식으로 충전시킨 후 양 도체 사이에 전기를 흐르게 함으로써 고분자에 의한 전열을 이용한 전기 발열체이다. 정온전선은 가격이 저렴하고 시공이 편리하기 때문에 겨울철 수배관의 동파방지용 열선으로 주로 사용되고 있다. 하지만 이러한 유용함에도 불구하고 구조적인 문제로 인하여 두 평형 도체의 절연이 파괴되는 경우에는 화재로 이어질 수도 있는 위험성이 존재하고 있다. 본 논문은 정온전선에 의한 화재현장을 조사하여 원인을 도출하는 방식으로 직접적인 원인을 추론하고자 하였으며, 결함수 분석을 통해 근본적인 문제를 파악해 보고자 하였다. 실제 냉동창고 화재현장을 조사하여 정온전선에 의한 화재원인을 추론한 결과 전선 말단 절연처리 결함에 의한 절연파괴인 것으로 판단되었다. 향후 이 결과는 안전활동 및 유사 화재원인조사 시에도 활용될 수 있을 것이다

자동차 임의배선에 의한 화재발생 가능성 연구 (Study on the Possibility of Car Fire by Arbitrary Electrical Wiring)

  • 김민;윤장수
    • 한국화재조사학회학술대회
    • /
    • 한국화재조사학회 2011년도 제20회 추계학술대회
    • /
    • pp.91-119
    • /
    • 2010
  • 자동차 수의 증가와 함께 자동차 화재 또한 꾸준한 증가 추세에 있다. 본 연구에서는 자동차 화재의 여러 요인들 중 자동차 출고 이후에 사용자에 의하여 변형된 부분, 즉 자동차 튜닝으로 인하여 화재가 발생할 가능성을 입증하고자 하였다. 실험 결과 전조등의 밝기를 향상시키기 위한 교체, 멀티시거잭 배선의 허용전류를 초과하여 전기장치를 사용하는 경우, 전선의 손상, 그리고 시중에서 튜닝용으로 구입하여 사용하는 전기배선의 취약성 등이 화재 가능성에 영향을 미치는 것으로 나타났다.

  • PDF