• 제목/요약/키워드: electrical fire investigation

검색결과 87건 처리시간 0.018초

전기화재 조사를 위한 분류체계 개발 (Development of a Classification System for an Electrical Fire Investigation)

  • 이종호;김두현
    • 한국안전학회지
    • /
    • 제20권3호
    • /
    • pp.53-57
    • /
    • 2005
  • This paper presents development of a classification system for an electrical fire investigation. In order to reduce an electrical fires and establish detailed prevention plans, the collection of an electrical fire causes and base data are very important. Based on this data, a new classification system for an electrical fire investigation was developed and the direction to the classification system was suggested by fundamental analysis. All of the collected information is analyzed by bottom-up method. Criteria items which based on base data were categorized to classify items. The classification of items were found out as follows : basic condition fire scene condition, fire sign, fire cause. Particularly, the fire cause category is classified. A new developed classification system for an electrical fire investigation will be used to analyse electrical fires easily and efficiently.

EMTP 시뮬레이션을 통한 배전선로의 1선 지락 사고시 화재 조사 기법에 관한 연구 (A Study on Fire Investigation Technique For Single Line to Ground Faults in Distribution Line Using EMTP Simulation)

  • 유정현;김희식;이훈기;조용선
    • 한국안전학회지
    • /
    • 제33권3호
    • /
    • pp.21-26
    • /
    • 2018
  • Approximately 20% of the total fire is electrical fire, and electrical energy is a potential source of heat. Large-scale fault currents that occur during a line ground fault flow into electric utility poles, electric power equipment, or electric appliances of the customer, and cause simultaneous electrical fire. In this paper, we investigated the possibility of fire through the change of fault current flowing in faulty and sound feeder in case of 1 line ground fault in 22.9 kV distribution line. We propose a fire investigation analysis method for simultaneous multiple electrical fire such as evidence analysis method, and fault current occurrence confirmation method in case of fire accident by analyzing the fault current occurring in the ground fault in the distribution line using EMTP, electric power system analysis program.

모발건조기의 전기화재 위험요소에 따른 화재 감정기법 연구 (Study of Fire Appraisal Method According to Electrical Fire Hazards of Hair Dryer)

  • 문현욱;이기연;김동우;길형준;김향곤
    • 조명전기설비학회논문지
    • /
    • 제25권12호
    • /
    • pp.113-118
    • /
    • 2011
  • In this study, investigation and appraisal method for the scene of a fire according to electrical fire hazards of hair dryer which is usually used at living space are presented. Hair dryer is briefly composed of heating part, wind part and control part. Electrical fire hazards of hair dryer are insulation destruction of power cord, ignition by overheat of heating coil, scattering spark on inside dust, overheat of motor by fan shackle, ignition by carelessness of user, and so on. Fire cause by hair dryer can be perceived through investigation about half-disconnection of power cord, contact badness of power plug, verification of heating coil, fan and switch. These results are expected to be utilized effectively in a countermeasure to prevent an electrical fire by hair dryer.

화재조사전문교육 및 자격증제도 개선에 관한 연구 (A Study on Improvement of Professional Fire Investigation Education and Certification System)

  • 고기봉;이시영
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.32-42
    • /
    • 2009
  • 본 연구는 국내의 화재조사전문교육 운영 실태를 분석하고 개선방안을 도출하는데 있다. 연구결과 현재의 화재조사전문교육은 공적영역(소방, 경찰, 전기안전공사, 가스안전공사 등) 중심으로 이루어지고 있으며 중앙소방학교에서 실시하고 있는 교육이 가장 체계적인 것으로 나타났다. 그리고 사적영역(화재피해이재민, 일반국민 등)을 대상으로 하는 화재조사전문교육은 거의 이루어지고 있지 않는 것으로 나타났다. 이러한 문제점을 개선하기 위해서 현행 중앙소방학교를 평생교육체제로 전환하여 대학의 학위과정과 연계하고 소방방재청에서 시행하고 있는 화재조사관자격증 제도를 외부에 개방 및 학습수준별 5단계로 나누어 운영할 것을 제안하였다.

도전성 분말에 의한 아크전류의 파형 및 실효값 특성 (Characteristics on Arc Waveform and RMS of Current by Conductive Powder)

  • 김두현;강양현
    • 한국안전학회지
    • /
    • 제28권3호
    • /
    • pp.63-68
    • /
    • 2013
  • This paper is aimed to make an analysis on characteristics of the parallel arc waveform and RMS of current at the electrical tracking state by conductive powder. In order to achieve the goal in this paper, field state investigation at metal processing companies in Chung-Nam province area was conducted. With the field state investigation, conductive powder were collected from metal processing companies. By experiment on electrical connector(breaker, connector) over which the conductive powder were scattered, arc waveform and RMS of current were measured. The measured waveform and RMS(root-mean-square) of current were analyzed to describe characteristics and patterns of electrical arc by the conductive powder. It was proved that conductive powder on electrical connector can flow electrical current enough to make electrical fire with high thermal energy. Also the change of sine waveform and RMS of current can be used to find out relationship between electrical fire and fault signal by conductive powder. The results obtained in this paper will be very helpful for the prevention of electrical fires occurred at the metal processing companies.

전기화재의 발생원인 및 분석에 관한 연구 - 전선의 열해석을 통하여 - (A Study on the Causes and the Analysis of Electrical Fires - focused on Heat Analysis for Electrical Wires-)

    • 한국화재소방학회논문지
    • /
    • 제16권4호
    • /
    • pp.72-76
    • /
    • 2002
  • 오늘날 전기화재의 정확한 원인분석과 조사가 전계-열계해석 소프트웨어의 발전에 힘입어 전계-열계 해석 이론을 바탕으로 컴퓨터 시뮬레이션에 의해 체계적으로 연구되고 있으나, 매우 미흡한 실정이다. 따라서 본 논문에서는 상기의 상황에 기초해서 국내 L사 제품(600V, VVF : Three Core)의 전선을 모델로 하여 과부하 및 단락사고시 발생되는 전류 크기 및 열화시간에 따른 전선의 열해석을 전계-열계 유한요소법(Flux2D)를 통하여 컴퓨터 시뮬레이션 하고자 한다.

저압 배선선로의 과부하 및 단락사고 발생시 전선의 열해석에 관한 연구 (A Study on the Thermal Analysis for Electrical Wire in Overload and Short of Low Voltage Wiring)

  • 이상호;오홍석
    • 한국화재소방학회논문지
    • /
    • 제16권3호
    • /
    • pp.56-60
    • /
    • 2002
  • 최근 전계-열계해석 소프트웨어의 발전에 힘입어 전계-열계 해석 이론을 바탕으로 컴퓨터 시뮬레이션에 의한 전기화재의 정확한 원인분석과 조사가 체계적으로 연구되고 있으나, 매우 미흡한 실정이다. 따라서 본 논문에서는 국내 L사 제품(600V, VVF)의 전선을 모델로 하여 과부하 및 단락사고시 발생되는 전류 크기에 따른 전선의 열해석을 전계-열계 유한요소법(Flux2D)을 통하여 컴퓨터 시뮬레이션 하고자 한다.

전원코드 접속부에서의 접촉불량에 의한 열화특성 분석 (The Analysis of Deterioration Characteristics by Poor Contact at the Connection Part of Power Cord)

  • 김향곤;이기연;문현욱;김혁수;김명수;김만건
    • 한국화재조사학회학술대회
    • /
    • 한국화재조사학회 2010년도 제 19회 춘계학술대회
    • /
    • pp.66-81
    • /
    • 2010
  • 본 논문에서는 콘센트와 플러그 접속부에서의 접촉불량에 의한 열화특성에 대하여 실험, 분석하였다. 부하의 크기와 시간 경과에 따른 전기적 특성을 분석하였으며 도전 재료와 절연재료의 외형, 표면구조, 열화특성을 분석하였다. 실험결과는 접촉불량에 의한 전기화재 예방과 화재원인 분석에 활용 가능할 것으로 기대된다.

  • PDF

전기화재원인분류의 문제점 분석 및 개선안 제시 (Improvement and Analysis for an Electrical Fire Cause Classification)

  • 이종호;김두현;김성철
    • 한국화재소방학회논문지
    • /
    • 제23권2호
    • /
    • pp.36-40
    • /
    • 2009
  • 본 논문은 전기화재 통계의 신뢰성을 향상시키고 효율적인 전기화재 자료를 수집하기 위한 전기화재 원인분류의 개발에 관한 연구이다. 전기화재에 대한 잘못되거나 편향된 지식은 전기화재에 대한 형태 분류를 바뀌게 한다. 전기화재 원인분석에 있어 화재조사자들이 올바르게 보고서를 작성할 수 있는 표준화된 형식을 개발하는 것이 필요하다. 본 연구에서는 원인들간의 인과관계를 고려한 계층구조로 새롭게 개발된 전기화재 원인분류체계를 제안하였다. 그리고 제안된 분류체계는 전기화재 조사 및 통계에 사용될 수 있으며, 전기화재 진단의 오류를 최소화할 수 있다.