• Title/Summary/Keyword: electrical fire investigation

Search Result 87, Processing Time 0.03 seconds

Development of a Classification System for an Electrical Fire Investigation (전기화재 조사를 위한 분류체계 개발)

  • Lee, Jong-Ho;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.53-57
    • /
    • 2005
  • This paper presents development of a classification system for an electrical fire investigation. In order to reduce an electrical fires and establish detailed prevention plans, the collection of an electrical fire causes and base data are very important. Based on this data, a new classification system for an electrical fire investigation was developed and the direction to the classification system was suggested by fundamental analysis. All of the collected information is analyzed by bottom-up method. Criteria items which based on base data were categorized to classify items. The classification of items were found out as follows : basic condition fire scene condition, fire sign, fire cause. Particularly, the fire cause category is classified. A new developed classification system for an electrical fire investigation will be used to analyse electrical fires easily and efficiently.

A Study on Fire Investigation Technique For Single Line to Ground Faults in Distribution Line Using EMTP Simulation (EMTP 시뮬레이션을 통한 배전선로의 1선 지락 사고시 화재 조사 기법에 관한 연구)

  • Yoo, Jeong Hyun;Kim, Hie Sik;Lee, Hoon Gi;Cho, Yong Sun
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.21-26
    • /
    • 2018
  • Approximately 20% of the total fire is electrical fire, and electrical energy is a potential source of heat. Large-scale fault currents that occur during a line ground fault flow into electric utility poles, electric power equipment, or electric appliances of the customer, and cause simultaneous electrical fire. In this paper, we investigated the possibility of fire through the change of fault current flowing in faulty and sound feeder in case of 1 line ground fault in 22.9 kV distribution line. We propose a fire investigation analysis method for simultaneous multiple electrical fire such as evidence analysis method, and fault current occurrence confirmation method in case of fire accident by analyzing the fault current occurring in the ground fault in the distribution line using EMTP, electric power system analysis program.

Study of Fire Appraisal Method According to Electrical Fire Hazards of Hair Dryer (모발건조기의 전기화재 위험요소에 따른 화재 감정기법 연구)

  • Moon, Hyun-Wook;Lee, Ki-Yeon;Kim, Dong-Woo;Gil, Hyung-Jun;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.113-118
    • /
    • 2011
  • In this study, investigation and appraisal method for the scene of a fire according to electrical fire hazards of hair dryer which is usually used at living space are presented. Hair dryer is briefly composed of heating part, wind part and control part. Electrical fire hazards of hair dryer are insulation destruction of power cord, ignition by overheat of heating coil, scattering spark on inside dust, overheat of motor by fan shackle, ignition by carelessness of user, and so on. Fire cause by hair dryer can be perceived through investigation about half-disconnection of power cord, contact badness of power plug, verification of heating coil, fan and switch. These results are expected to be utilized effectively in a countermeasure to prevent an electrical fire by hair dryer.

A Study on Improvement of Professional Fire Investigation Education and Certification System (화재조사전문교육 및 자격증제도 개선에 관한 연구)

  • Ko, Gi-Bong;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.32-42
    • /
    • 2009
  • This study aims to analyze operation status of the professional fire investigation education in Korea and derive improvement measures. Study results showed that professional fire investigation educations are conducted mainly by public sectors (Fire Service, Police, Korea Electrical Safety Corp, Korea Gas Safety Corp, etc.) and the educations conducted by National Fire Service Academy are most systematic. In addition, there was no professional fire investigation educations conducted for private sector (fire accident suffers, common peoples, etc.) In order to improve the problems, this study suggests changing the National Fire Service Academy to lifelong education system in coordinance with the scholar's courses of universities, classifying the fire inspector qualification course (executed by National Emergency Management Agency) in five stages, and opening the fire inspector qualification test to the public.

Characteristics on Arc Waveform and RMS of Current by Conductive Powder (도전성 분말에 의한 아크전류의 파형 및 실효값 특성)

  • Kim, Doo Hyun;Kang, Yang Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.63-68
    • /
    • 2013
  • This paper is aimed to make an analysis on characteristics of the parallel arc waveform and RMS of current at the electrical tracking state by conductive powder. In order to achieve the goal in this paper, field state investigation at metal processing companies in Chung-Nam province area was conducted. With the field state investigation, conductive powder were collected from metal processing companies. By experiment on electrical connector(breaker, connector) over which the conductive powder were scattered, arc waveform and RMS of current were measured. The measured waveform and RMS(root-mean-square) of current were analyzed to describe characteristics and patterns of electrical arc by the conductive powder. It was proved that conductive powder on electrical connector can flow electrical current enough to make electrical fire with high thermal energy. Also the change of sine waveform and RMS of current can be used to find out relationship between electrical fire and fault signal by conductive powder. The results obtained in this paper will be very helpful for the prevention of electrical fires occurred at the metal processing companies.

A Study on the Causes and the Analysis of Electrical Fires - focused on Heat Analysis for Electrical Wires- (전기화재의 발생원인 및 분석에 관한 연구 - 전선의 열해석을 통하여 -)

    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.72-76
    • /
    • 2002
  • Nowaday, with the growth of software for electro-thermal analysis, it has been studied the precise analysis and investigation of cause for the electrical fire using computer simulation on the basis of theory for electro-thermal analysis. But it is very lacking for the precise analysis and investigation of cause for the electrical fire. In this paper, we have simulated the thermal analysis for electrical wire according to the value of current and deteriorating time in a overload and a short with the electrical wire of the L's company product(600 V VVF : Three core) using the elec-tro-thermal finite element method(Flux2D).

A Study on the Thermal Analysis for Electrical Wire in Overload and Short of Low Voltage Wiring (저압 배선선로의 과부하 및 단락사고 발생시 전선의 열해석에 관한 연구)

  • 이상호;오홍석
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.56-60
    • /
    • 2002
  • Recently, with the growth of software for electro-thermal analysis, it has been studied the precise analysis and investigation of cause for the electrical fire using computer simulation on the basis of theory for electro-thermal analysis. But it is very lacking for the precise analysis and investigation of cause for the electrical fire. In this paper, we have simulated the thermal analysis for electrical wire according to the value of current in a overload and a short with the electrical wire of the L's company product(600 V VVF) using the electro-thermal finite element method(Flux2D).

The Analysis of Deterioration Characteristics by Poor Contact at the Connection Part of Power Cord (전원코드 접속부에서의 접촉불량에 의한 열화특성 분석)

  • Kim, Hyang-Kon;Lee, Ki-Yoen;Moon, Hyun-Wook;Kim, Hyeog-Soo;Kim, Myung-Soo;Kim, Man-Geon
    • Congress of the korean instutite of fire investigation
    • /
    • 2010.06a
    • /
    • pp.66-81
    • /
    • 2010
  • In this study, we experimented and analyzed deterioration characteristics of outlets and power cord sets caused by poor contact. Electrical waveforms were measured according to load size and elapsed time. After that, surface structure and deteriorated characteristics of conductive materials and insulators were analyzed. We hope that the results will be applicable to electrical fire prevention and accidents analysis.

  • PDF

Improvement and Analysis for an Electrical Fire Cause Classification (전기화재원인분류의 문제점 분석 및 개선안 제시)

  • Lee, Jong-Ho;Kim, Doo-Hyun;Kim, Sung-Chul
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.36-40
    • /
    • 2009
  • This paper presents research about the development of electrical fire cause classification in order to improve the reliability of electrical fire statistics and to collect electrical fires data efficiently. The incorrect and biased knowledge for electrical fires changed the classification of certain types of fires, from non-electrical to electrical. It is convenient and required to develop the standardized form that makes, in the assessment of the cause of electrical fires, the fire investigators directly ticking the appropriate box on the fire report form or making an assessment of a text description. In this study, newly developed electrical fire cause classification structure, which is well-defined hierarchical structure so that there are not any relationship or overlap between cause categories, is suggested. Also the suggested classification structure can be used for electrical fire investigation and statistics, which minimizes the mistake that diagnose non-electrical fires into electrical ones.