• Title/Summary/Keyword: electrical facilities

Search Result 1,212, Processing Time 0.034 seconds

Analysis of Overseas Educational Informatization Infrastructure Evaluation Indicators (해외 교육정보화 인프라 평가 지표 분석)

  • Ahn, Sung Hun;Lee, Sanghyeon
    • Journal of Creative Information Culture
    • /
    • v.6 no.1
    • /
    • pp.49-56
    • /
    • 2020
  • The purpose of this study is to examine overseas educational informatization infrastructure evaluation indicators and create data for establishing and developing educational informatization policy directions in the future. We analyzed the cases of OECD PISA, UNESCO, ITU, the German Wetelsmann Foundation, the U.S. Department of Education, and China as educational indicators. As a result of the analysis, evaluation items for electrical and telecommunication facilities such as the school's Internet connection network were commonly found in all indicators, and the ratio of learners to PCs (LCR) was also found in 3 out of 4 indicators. Through this study, it is expected that it will be of great help in conducting educational informatization evaluation suitable for the rapidly changing modern society and developing evaluation tools.

IoT Platform System for Electric Fire Prediction and Prevention (전기화재 예측 및 예방을 위한 IoT 플랫폼 시스템)

  • Yang, Seungeui;Lee, Sungock;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.2
    • /
    • pp.223-229
    • /
    • 2022
  • During the winter season, when the weather gets colder every year, electricity consumption increases rapidly. The occurrence of fires is increasing due to a short circuit in electrical facilities of buildings such as markets, bathrooms, and apartments with high population density while using a lot of electricity. The cause of these short circuit fires is mostly due to the aging of the wires, the usage increases, and the excessive load cannot be endured, and the wire sheath is melted and caused by nearby ignition materials. In this paper, the load and overheat generated in the electric wire are measured through a complex sensor composed of an overload sensor, a VoC sensor, and an overheat sensor. Based on this, big data analysis is carried out to develop a platform capable of predicting, alerting, and blocking electric fires in real time, and a simulator capable of simulated fire experiments.

Evaluation of Electrical Conductivity Reduction of CDI and RO for Salt Removal in Developing Countries (개발도상국 염분 제거를 위한 CDI와 RO의 전기전도도 감소 성능평가)

  • Kim, Beomgyu;Yang, Dongjin
    • Journal of Appropriate Technology
    • /
    • v.6 no.2
    • /
    • pp.183-189
    • /
    • 2020
  • Developing countries are areas where many problems arise from poor drinking water infrastructure. Developing countries often use groundwater as their primary source of drinking water, which causes problems. Among them, coastal areas are easily exposed to saltwater intrusion due to their geographical characteristics. Groundwater in areas exposed to saltwater intrusion has higher salinity than usual. If you continue to consume high salinity groundwater can cause a variety of fatal effects on the human body. Therefore, various alternatives have been proposed. This study explores the applicability of CDI(Capacitive Deionization) and RO(Reverse Osmosis) for water purification systems in areas where saltwater intrusion has occurred. Therefore, we will evaluate this by conducting water purification experiment. On the other hand, the supply of electricity is also important in the operation of water purification facilities. However, in many areas of developing countries, electricity is often not available. Therefore, this study intends to calculate the power consumption required for the actual use of the filter and to include it in the evaluation.

IT-based physical activity and exercise programs for individuals with spinal cord injury

  • Choi, Hyunhee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.2
    • /
    • pp.187-194
    • /
    • 2022
  • This study is to encourage physical activity and exercise in people with spinal cord disabilities so that they can have a positive effect on health outcomes. Current evidence shows that IT-based muscle strength and muscle endurance, cardiopulmonary exercise, electrical stimulation exercise, and robot exercise can all improve physical components, reduce the risk of secondary health complications, and have a positive impact on the overall health of people with chronic physical disabilities. To improve muscle strength and muscle endurance, exercise frequency should be conducted twice and three sets a week, <5 Reps to improve muscle strength, general strength should be repeated 6 to 15 times, and 15 to 30 times to improve muscle endurance. In order to improve cardiopulmonary ability, it should be conducted 3-5 times a week, 20-60 minutes, and 50-80% of the maximum heart rate. Therefore, higher resource investment is needed to realize various IT-based exercise benefits and access professional equipment, facilities and trainers.

Exploratory Investigation for Some Universities' E-Learning Systems during Covid-19 Pandemic

  • Fatima Rayan Awad, Ahmed;Thowiba E., Ahmed;Rashid A., Saeed;Elmustafa Sayed, Ali;Ghada Elnour Elterafi, Abdelrhman;Somia Yousif Ahmed, Abutiraima
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.12
    • /
    • pp.160-170
    • /
    • 2022
  • COVID pandemic has reshaped the world as it has been known to us and the education system is one of the most affected by it. Due to social distancing, quarantines and isolations have made it impossible for the knowledge transition to the masses using conventional methods. For cope with pandemic, the only other way available for some of the fortunate countries is the use of E-learning having somewhat the same traditional teaching method. This paper is concerned with the study of the preparedness of the learning system in some Sudanese universities due to the impact of the COVID-19 pandemic. Critical analysis has been performed to evaluate the current developing scenario, usage of the facilities available in open-source platforms, and the interaction of the universities folks with e-learning systems. The impact of such measures has been thoroughly investigated in this paper for Sudan which is already deprived of a proper education system. The investigation shows that the interact of the staff and the students with the system was acceptable where more than 85% of those enrolled to the system were interact properly and efficiently. The lecturers conducted through the platform were attended with more than 75% of the students. We also found that most of the lecturer were avoid to exam students by utilize the platform; where only 45% of the uploaded courses were conducted exams over Moodle platform. As Moodle is an open source and still need to be improved to be used for high examination credibility.

Development of Inspection Checklist through the Analysis of the Relationship between the Risk Improvement Ratio and the Accident Ratio in Food Manufacturing Industry (식료품 제조업 유해·위험요인 개선율과 재해율의 관계 분석을 통한 점검 체크리스트 개발)

  • Ho houng Yu;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.4
    • /
    • pp.47-53
    • /
    • 2023
  • In the inspection of workplace hazards/risk factors by specialized institutions dedicated to safety management, inspection reports vary based on the inspectors, who lack the authority to enforce improvement of workplace hazards/risk factors. Thus, improvement and accident rates remain steady without decreasing. This study performed a regression analysis on the relationship between improvement and accident rates of categorized inspection items by classifying hazards/risk factors from inspection reports submitted by a specialized safety management institution in Chungbuk after inspecting 10 food and beverage manufacturers over the past three years. The hazards/risk factors were classified into five categories: mechanical, electrical, chemical, human, and environmental. The regression analysis revealed that the improvement rate of hazards/risk factors inspected by the specialized safety management institution influenced accident rates. To enhance improvement rates based on these findings, this study prioritized the correction of the five most frequently cited inspection items with the lowest improvement rates in each area. Based on these inspection items, this study suggested a checklist for use in workplace safety inspections of food manufacturers. This proposed checklist is expected to reduce accident rates in food manufacturing facilities. Currently, guidance and inspection of workplaces are mainly focused on accident rates rather than correcting hazards/risks. Thus, accident rates remain unchanged as workplace risks are inadequately improved according to the unique characteristics of each workplace. When conducting workplace guidance and inspection, policy measures and inspection methods are warranted to increase the improvement rate of hazards/risks.

A Study on Implementation of FEMS for Chemical Industry Complex (화학 산업단지 FEMS 구축 연구)

  • Soo-Min Yoo;Soo-Woong Back;Jung-Min Lim;Chae-Joo Moon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.2
    • /
    • pp.277-284
    • /
    • 2023
  • It is not easy to implement an energy management system in an industrial complex where small businesses are scattered, so the method of collecting and adjusting energy-related data is mainly used. FEMS is a system that responds to the demand for a paradigm shift from a passive energy management method to an active energy management method using IoT and ICT. In this study, a factory energy management system(FEMS) is designed for small and medium-sized enterprises located in chemical industrial complexes. Efficiency was confirmed by reviewing energy saving measures and efficiencies through FEMS for the electric energy of facilities built in each company. The cost effectiveness of FEMS is created when it is utilized by responsible and empowered personnel within the business processes of the host company. Therefore, it is necessary to utilize EMS that can be applied to the planning, support, operation and evaluation, and continuous improvement of the energy management system to achieve corporate organization and energy management goals.

Design of Test Site for Large-Scale Wind Turbine Performance Verification (초대형 풍력터빈 시험을 위한 실증시험장 설계)

  • Sang-Man Kim;Tae-Yoon Jeong;Chae-Joo Moon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.3
    • /
    • pp.397-404
    • /
    • 2023
  • This paper designs a wind turbine test site based on international regulations for the certification of wind turbine prototypes. The maximum height of the meteorological mast installed at the test site is 140m, and power facilities capable of testing up to three wind turbines of 5MW or more are installed. The weather resources measured at the mast can be recorded and analyzed using a monitoring system. Wind turbine manufacturers can use this test site during the certification period, and the installed wind turbines can be used for continuous power generation projects. Therefore, this test site can provide fundamental data for measuring the long-term performance and durability of wind turbines, which can be used to improve models or develop new wind turbines.

Real-time Remote Monitoring System of Chemical Accident Response based on Multi-hop Communication (멀티 홉 통신을 기반한 화학 사고 대응 실시간 원격 모니터링 시스템)

  • Lee, Seung-Chul;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.11
    • /
    • pp.1706-1712
    • /
    • 2022
  • Recently, the safety of chemical substances has gained attention due to incidents occurring in petrochemical industrial complexes, such as gas leaks and fires. In particular, industrial complexes in Ulsan and Yeosu (South Korea) are valuable as they significantly contribute to the petrochemical industry, but accidents may occur due to chemical leakage. Therefore, in this study, sensor nodes are configured at an interval of 20 [m] based on outdoor facilities standards to respond to chemical accidents, and exposure consideration of 8 h (TWA) and 15 min (STEL) are proposed in TLVs. The proposed system pre-processes data collected in multi-hop communication at a cycle of 0.6-0.75 [s] using Python and stores it in the MySQL database through SQL and a real-time remote monitoring system that updates the stored data once every 5 s is implemented by linking MySQL and Grafana.

AN APPROACH FOR ESTIMATING TOTAL COST OF OCCUPATIONAL SAFETY FOR BUILDING CONSTRUCTIONS

  • Gurkan Emre Gurcanli;Nesimi Teoman Korkutan;Ugur Mungen
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.168-175
    • /
    • 2011
  • Construction accidents are major problem in Turkish Construction industry and especially fatally rates are very high. Current legislative system on occupational safety in Turkey enforces employers to implement safety measures as well as safety management systems. However level of consciousness in the industry is unsatisfactory and safety are perceived as extra cost and unnecessary expenditure. Moreover, especially in small residential building constructions which have a big share in the industry and unfortunately safety measures to mitigate or abate construction risks do not exist. The study focuses on small residential building construction sites and in the scope of this study, thirty building projects are examined. For each building project, project cost including labour and material costs, service and consultancy costs for mechanical, electrical systems as well as architectural and structural services, costs for supervision and finally general expenditures for construction site facilities were calculated. On the other hand, occupational safety costs for personal protective equipment, collective protective measures, consultancy and training were determined. Work breakdown structures were established and for each work item firstly occupational risks were evaluated and furthermore according to risk scores safety measures to be implemented were defined and related costs were calculated. The study gave results for total safety cost on average, in terms of percentage of total project cost (3.73% of total project cost), safety cost per man-hour (0.40 USD) and safety cost in terms of unit construction area (11.60 USD per square meter). Since safety management is a part of whole project management process, study gives suggestions and techniques to calculate safety costs and implement safety measures as a part of project management service for professionals. Authors believe that suggested approach may easily developed by the usage of more data to establish a model for estimation not only for building construction sites but also for all construction projects.

  • PDF