• Title/Summary/Keyword: electrical facilities

Search Result 1,212, Processing Time 0.032 seconds

A Study on Battery Charging and Supply System of Electric Vehicle Using Photovoltaic Generation (태양광 발전을 이용한 전기자동차 배터리 충전 및 공급시스템에 관한 연구)

  • Choi, Hoi-Kyun
    • Journal of Climate Change Research
    • /
    • v.8 no.3
    • /
    • pp.265-273
    • /
    • 2017
  • Recently the Paris Climate Change Accord has been officially put into effect, making global efforts to implement Greenhouse Gas (GHG) reductions, and also International environmental regulations in the automotive sector will be further strengthened. The electric vehicle, which minimizes the particulate matter generated by existing internal combustion engine automobiles, is evaluated as a representative eco-friendly automobile. However, charging the battery of an electric vehicle is not fully environment-friendly if it is fueled by electricity that is being generated by fossil fuels as an energy source. The energy generated by the photovoltaic power generation system, which is an infinite clean energy, can be used to charge an electric vehicle's battery. Currently, shortage of charging facilities, time of charging, and high battery prices are the problem of activating the supply of electric vehicles. This study is to build a conjunction between the EVBSS (Electric Vehicle Battery Supply System) and ESS (Energy Storage System), which can quickly supply the photovoltaic charged battery to the required demand. If the charged battery in the Battery Swapping Station (BSS) is swapped swiftly, it will dramatically shorten the waiting time for charging the battery. As a result, if the battery is rented when it is needed, electric vehicles can be sold without the cost of a battery, which accounts for a large portion of the total cost, then the supply of electric vehicles are expected to expand. Furthermore, it will be an important alternative to maneuver climate change by minimizing GHG emissions from internal combustion engine vehicles.

A Study on the Fire Risk of ESS through Fire Status and Field Investigation (화재현황 및 현장조사를 통한 ESS의 화재 위험성 연구)

  • Park, Kwang-Muk;Kim, Jae-Hyun;Park, Jin-Yeong;Bang, Sun-Bae
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.91-99
    • /
    • 2018
  • Recently, the spread of ESS in Korea has increased and a fire accident has also occurred. By July 2018, there were a total of 7 cases. All 7 cases were ESS systems consisting of lithium-ion batteries and were burned down. Both the automatic fire extinguisher and the fire department were not able to digest. In this paper, the characteristics of ESS fire are analyzed based on recent ESS fire situation and field investigation, and the cause of fire is divided into environmental, electrical and thermal factors. As a result, it was found that the ESS fire was correlated with the installation environment of the system. In the domestic and overseas lithium ion battery test standard and ESS facility standard survey, the trends and differences of domestic and overseas facilities standards were identified. Based on the fire status and field investigationy, and domestic and overseas facility standard survey, measures were suggested to prevent and prevent the spread of fire in ESS fire.

Analysis of Commercial Recycling Technology and Research Trend for Waste Cu Scrap in Korea (국내 구리 함유 폐자원의 재활용 상용화 기술 및 연구동향 분석)

  • Kang, Leeseung;An, HyeLan;Kang, Hong-Yoon;Lee, Chan Gi
    • Resources Recycling
    • /
    • v.28 no.1
    • /
    • pp.3-14
    • /
    • 2019
  • Copper is used in many electronic components and construction parts due to its excellent electrical conductivity and heat transfer characteristics, and also used for pre-plating for double layer coating such as nickel, so that copper is an essential material in modern industry. Despite the expected increase of usage and importance on wiring, sensors and data equipment in the next generation industries, it is hard for securing stable copper supply and resource management resulting from the copper prices are fluctuating owing to the economic crisis in Europe, the low economic growth trend in China, and President Trump's commitment to public industrial facilities investment in U.S.. Since most of the domestic copper consumption is used by electrolytic copper cathode, we studied not only copper recycling technology which is being commercialized but also current research trend under the research stage. This study aims to examine the characteristics of each process and the areas where future recycling technology development is required.

Design of a Planar Log-Spiral Antenna for Testing Plane-Wave Shielding Effectiveness (평면파 차폐효과 시험용 평판형 로그 스파이럴 안테나 설계)

  • Chung, Yeon-Choon
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.762-767
    • /
    • 2019
  • The plane-wave shielding effectiveness is typically measured for horizontal and vertical polarizations using a linearly polarized antenna. However, this typical measurement method results in big evaluation fees due to very long measurement time as well as huge idle space for maintenance, these problems is more severe especially in large shielded enclosures such as EMP protection facilities to be built in indoor buildings and underground. This paper describes the design and fabrication process and results of a planar log-spiral antenna applicable to the evaluation of the electromagnetic shielding effectiveness of a large EMP protection facility. Since the proposed antenna has a circular polarization, there is no need to separately measure the horizontal and vertical polarizations. Therefore, the measurement time can be shortened by more than 1/2, and further, its small volume with a planar structure can reduce greatly idle space required for the maintenance.

Integrated Management System to Improve Photovoltaic Operation Efficiency (태양광발전 운영효율 향상을 위한 통합관리시스템)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.4
    • /
    • pp.113-118
    • /
    • 2019
  • A solar power plant is a facility that produces electricity. As the risk of fire and electric shock accidents is diversified, the risk of workers, surrounding people, and facilities is increased, preventing safety accidents and promptly responding to safety accidents Is emerging. In light of the necessity of such development, it is necessary to develop a solar power generation management system that can diagnose and maintain the problems of the power generation system in real time by developing technologies for collecting and analyzing the data produced by the solar power generation system As a result, the utilization rate and the maintenance cost can be reduced. In order to do this, it is necessary to accurately predict the solar power generation amount in the present state, to diagnose the abnormality of the current power generation state and to grasp the abnormal position, and to use the model considering economical efficiency when the abnormal position is grasped, And the time and other information should be provided.

Analysis of the Characteristics of the Change in the Moisture Rate of Landfill with Recirculation Water Injection (재순환수 주입에 따른 매립장 함수율 변화특성 분석)

  • Kim, Young-Kyu;Choi, Won-Young;Chun, Seung-Kyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.5
    • /
    • pp.39-48
    • /
    • 2021
  • Analysis of the change in water content and distribution was conducted according to the supply of recirculation water to a landfill. An excavation sample analysis showed that the recirculation water injection zone had water content 8.8% point higher than that of the non-injection zone, after 8 months of operation. And due to the influence of recirculation water supply by vertical wells in injection zones, the water content increases along with depth more clearly than non-injection zone. According to an electrical specific-resistivity survey after 13 months of operation, the water content got higher towards the bottom of the landfill. The water transmission coefficient is 8.72×10-4 cm/sec for injection zones and 3.36×10-5 cm/sec for the intermediate cover layer; analysis shows that the intermediate cover layer may affect the penetration velocity of water supplied by the horizontal injection tube. For the scientific design and operation of re-injection facilities, it was deemed necessary to follow-up research on the residence time and behavior of re-injection water considering the ratio of recirculation water supply in horizontal and vertical tubes, and pitcher coefficient of intermediate and waste layers.

A Study on the Correction of Protection Relay of Temporary Electric Power Installations for Storage Tank (저장 탱크용 임시전력설비의 보호계전기 정정에 관한 연구)

  • Son, Seok-Geum
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.6
    • /
    • pp.562-567
    • /
    • 2020
  • In this paper, this is a study on the correction of protection relays to monitor temporary power facilities for storage tanks especially transformers to block and protect faults such as insulation breakdown. When an abnormality such as a short circuit or a ground fault occurs in the power system, it is important to detect this quickly cut off the device and equipment in which the fault occurred and separate it from the power system to correct the protection relay so that it does not interfere with power supply. In addition the fault current calculation that accurately applies the fault type and the cause of the fault for protection cooperation will be the most important factor in the correction of the protection relay. For protection coordination a study was conducted on the method of coordination for protection of power facility protection for storage tanks such as over current relay, ground over current relay, under voltage relay, and ground over voltage relay applied to temporary.

Intrusion Detection Methodology for SCADA system environment based on traffic self-similarity property (트래픽 자기 유사성(Self-similarity)에 기반한 SCADA 시스템 환경에서의 침입탐지방법론)

  • Koh, Pauline;Choi, Hwa-Jae;Kim, Se-Ryoung;Kwon, Hyuk-Min;Kim, Huy-Kang
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.22 no.2
    • /
    • pp.267-281
    • /
    • 2012
  • SCADA system is a computer system that monitors and controls the national infrastructure or industrial process including transportation facilities, water treatment and distribution, electrical power transmission and distribution, and gas pipelines. The SCADA system has been operated in a closed network, but it changes to open network as information and communication technology is developed rapidly. As the way of connecting with outside user extends, the possibility of exploitation of vulnerability of SCADA system gets high. The methodology to protect the possible huge damage caused by malicious user should be developed. In this paper, we proposed anomaly detection based intrusion detection methodology by estimating self-similarity of SCADA system.

A Study on the Strategy of Sustainable Hospital Architecture Masterplan (지속가능한 병원건축 마스터플랜 전략에 관한 연구)

  • Park, Cheolkyun;Yang, Naewon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.4
    • /
    • pp.15-26
    • /
    • 2020
  • Purpose: The purpose of this study is to derive a plan to establish a more sophisticated master plan so that the direction of master plan study can be sustained in the mid to long term. Methods:: Compare and analyze the differences between the master plan and the design to identify causes and problems. First, after establishing the master plan, compare the expansion area, net area per bed, and service area with the design drawing of the first project to determine the degree of recovery to the level required by the recent medical environment. Second, the possibility of responding to future internal changes is reviewed by comparing and analyzing the arrangement and connection method of extension buildings. Third, comparing the difference between the project following the first project and the phased of masterplan. Results: The first one is that continuous participation of person or group with high understanding of the master plan. Second, establishing a master plan and proceeding with the project through the determination of the correct business budget. Third, a specific area of the mechanical and electrical room suitable for the size and purpose of the hospital should be presented, and research on the arrangement method should be conducted. Finally, the feasibility of the hospital's own plan for securing parking facilities should be accurately investigated. Implications: It is important for the hospital to recover from the past to the present and respond to the future that the direction of the master plan continues after the establishment.

A Study on High performance Electrical Precipitation Technology for PM Removal in Exhaust Gas (배가스 내 미세먼지 제거를 위한 고성능 집진 기술에 대한 연구)

  • Kim, Soyeon;Kim, Minsung;Choi, Sangmi;Jung, Minkyu;Lee, Jinwook
    • Plant Journal
    • /
    • v.18 no.1
    • /
    • pp.50-54
    • /
    • 2022
  • The demand for high-efficiency dust collectors is rapidly increasing to remove PM from exhaust gas emission facilities, such as thermal power plants, steel mills, and industrial cogeneration plants, as the Pmemission standards have been strengthened. In this study, the electrospray is adapted for existing electrosratic precipitator(EP) to remedy its shortcomings and to improve the performance. Electrospray has been mainly used for the purpose of generating very fine droplets, but fir the purpose of EP, the flow rate over 10 mL/min per nozzleis required, and a high flow rate condition of 65 to 200 times is required. The electrospray of high flow rate has a completely different spray shape from the low flow rate condition, and was visualized through various figures such as corona discharge photographs and shadow images.

  • PDF