• Title/Summary/Keyword: electrical facilities

Search Result 1,223, Processing Time 0.038 seconds

Analysis of Domestic Apply Actual Condition about the Facilities of Amusement Electric Train (유희용전차의 시설에 관한 국내적용실태 분석)

  • Kim, Han-Sang;Kim, Chong-Min;Kim, Gi-Hyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.326-329
    • /
    • 2004
  • The electric train is a kind of amusement ride and it is installed in a lot of amusement parks. The object of this study was to analyze and to find out of problem about electrical facilities of amusement electric train. For the purpose of this study, we give careful consideration to the technical standard to be Notification of the Ministry of Commerce, Industry and Energy and foreign electrical codes and we carried out an actual condition investigation on twelve amusement electric trains from among domestic amusement parks. As a result, we could how that there is discrepancy between the electrical regulations and the actual condition.

  • PDF

Magnetic Field Measurement and Computer Simulation for Electrical Utility Facilities (전력설비에 의한 자계 측정및 컴퓨터 시뮬레이션)

  • Jeon, Hyung-Tae;Sa, Jae-Won;Hahn, Sung-Chin
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.22-24
    • /
    • 1996
  • For two decades and more, a lot of research work on the biological effects of EMF(Electromagnetic Fields) on Human hearth have been reported. Power-frequency magnetic fields are a natural consequence of the flow of electricity. This paper deals with the modeling of electric utility facilities taking into account the line geometries. The magnetic fields profiles obtained from the computer simulation arc compared to those from measurements.

  • PDF

Potential Distribution near Street Linght according to the Grounding Electrode (접지극 형상에 따른 가로등 주변의 전위분포)

  • Lee, Bok-Hee;Beak, Young-Hwan;Jeong, Dong-Cheol;Ahn, Chang-Hwan;Shim, Pan-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1453-1454
    • /
    • 2007
  • A street light is an electrical equipment to improve the traffic safety and the security for people in night. However, many accidents due to electric shock have happened in recent, people were interested in the safety of electrical facilities. And people want to know the danger by touch and step voltages. When the electric power lines fall down on the ground, the fault current flows to ground rod and the potential near the ground rod is increased to induce the high touch and step voltages. In this paper, we installed different ground rods with a street light and investigated the electrical potential according to ground methods and the types of ground rod. Finally, we examined the electrical facilities with the experimental result and present the improved technical data for the safety from electric shock

  • PDF

A Study on the Optimal Grounding Design using Pattern Search Method for Electric Power Facilities (전력사용 시설물의 Pattern Search 법을 이용한 최적 접지 설계에 관한 연구)

  • 최홍규;김경철;최병숙
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.173-180
    • /
    • 2001
  • Electric power facilities must have effective grounding to provide means to carry electric current into the earth under fault conditions and to prevent damage of equipment, Ignition, and electrocution of presonnel. nuts paper present an algorithm called the Pattern Search method for the optimal parameters selection of the grounding system. Computer simulation results used the CDEGS grounding analysis program verifying the effects of the grounding system design parameters obtained from this method show that the grounding systems are adequately designed.

  • PDF

Introduction of the Automatic Utility Program in Electrical Facilities (전기설비의 자동화 프로그램 소개)

  • 유상봉
    • Journal of the Korean Professional Engineers Association
    • /
    • v.33 no.4
    • /
    • pp.27-32
    • /
    • 2000
  • The automatic utility program in electrical facilities has specially developed to fulfill the needs of electric CAD designers . Designers had separately managed the designing factors such as design, estimates and calculation sheets . However, this automatic utility program produces calculation sheets and volume reports simultaneously while designed. The program also accumulates all data automatically in database in order to be utilized as the statistics and the design data for later project management. Moreover, it is easy for new and inexperienced users to access by using the standard electric symbol libraries and utility modules.

  • PDF

Application Technologies and Future Trend for Intelligent Home Networks (지능형 홈네트워크 응용기술 및 전망)

  • Suh Jeong-Jun;Kim Young-Yong
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.3 no.1
    • /
    • pp.126-133
    • /
    • 2004
  • 최근 홈 내에서는 PC나 가전기기의 수가 증가하며, 네트워크 활용이 커짐에 따라 홈네트워크 기술이 중요한 이슈로 떠오르고 있다. 이러한 홈네트워크 기술은 PC나 가전기기 사이에 통신이 가능하도록 하는 기술을 말한다. 본 논문에서는 홈네트워크와 관련된 여러 가지 홈네트워크 기술을 살펴보도록 한다. 또한 지능형 홈네트워크 기술과 함께 센서네트워크를 활용한 앞으로의 지능형 홈네트워크 기술에 대해서도 알아보도록 한다.

  • PDF

A Study on the Development of Remote Diagnosis System for Nerve Conduction

  • Kim, Jong-Weon
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.3
    • /
    • pp.286-291
    • /
    • 1998
  • A remote measurement system for nerve conduction has been developed to aid patients with spinal cord injury by accident. Existing cooperation between rescuers and doctors can be supported through the introduction of multimedia desktop video conferencing. Such facilities provide several advantages over conventional video conferencing. In particular, patients may feel free because they can see a doctor through the video conferencing facilities. This paper describes the system implementation and evaluation. The author considers the network capability and image data handling, and introduces a method a transmit image data for this system.

  • PDF

Performance of Turbo Coded MC-CDMA with Iterative Multiuser Detection and Decoding in a Nonlinear Fading Channel

  • Ghosh C.;Gangopadhyay R.
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.2 no.3
    • /
    • pp.17-23
    • /
    • 2003
  • Turbo decoding in combination with detection strategy for Multi Access Interference (MAI) cancellation has been shown to be very effective for MC-CDMA system in Rayleigh multi-path fading environment. This paper reports new simulation results on the efficacy of joint decoding and detection for MC-CDMA in nonlinear and fading channel.

  • PDF

Restructuring of Technical Regulation in Korea Electricity Business Act (전기사업법상 기술기준 개편)

  • Kim, Han-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.223-226
    • /
    • 2004
  • The Technical Regulation in Korea Electricity Business Act, shall be obeyed for design, installation and maintenance of electric facilities to ensure public safety and reliable supply of electricity. The Technical Regulation will be a basis for securing electrical safety, and also will be a governmental criterion for judging acceptance of the electric facilities from a safety viewpoint.

  • PDF

The Application and Seismic Design Method of Electrical Facility Installed in the Building (건축물에 시설되는 수변전설비의 내진설계 검토사항 및 설계 방안에 대한 고찰)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Bae, Suk-Myong;Cho, Sung-Gook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.74-79
    • /
    • 2009
  • In the case of that not considered seismic design at transformer vault which is equipped with many important electrical facilities, the facility is damaged, electrical fire breaks out and another damage may be caused due to earthquake. But seismic design has not yet applied to transformer vault in the country. Regard to seismic design method of electrical facility installed inside the building, the seismic design procedures for electrical facility is presented in this parer, which has been developed by referring "Building design standard" of domestic code and "Manual of seismic design and construction for building electrical facility" in japan. This paper may help engineers perform detail seismic design, construction and reliability inspection of electrical pipes and facilities.