• Title/Summary/Keyword: electrical control circuit

Search Result 1,790, Processing Time 0.035 seconds

Sinewave-PWM ZVS Inverter using High-Frequency Transformer for Utility AC Voltage Link

  • Chandhaket S.;Ogura K.;Konishi Y.;Nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.511-515
    • /
    • 2003
  • This paper presents a novel prototype of the utility-interfaced sinusoidal pulse width modulated (SPWM) inverter using the high-frequency flyback transformer fur the small-scale solar photo-voltaic power conditioner (1kW - 4kW). The proposed SPWM power conditioner circuit with a high-frequency link has a function of electrical isolation, which is vital fur solar photovoltaic power conditioner systems with the viewpoint of safety and convenience. The discontinuous conduction mode (DCM) operation of the flyback transformer is also maintained to simplify the topology of the inverter circuit and control scheme. First, the operating principle of the proposed circuit is described far the understanding of the circuit parameters establishment. Then, the digitally constructed SPWM control scheme is presented. The proposed circuit is verified by the computer simulation and the prototype experiment.

  • PDF

A study on the vibration of 2-phase HB type Linear Stepping Motor (2상 HB형 선형 STEPPING 전동기의 진동해석에 관한 연구)

  • Oh, H.S.;Jung, E.N.;Sim, S.H.;Lim, Y.H.;Lee, S.K.;Shim, J.S.;Shim, N.S.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.852-854
    • /
    • 2001
  • In this paper, the vibration characteristics of a 2-phase Hybrid type Linear Stepping Motor(HLSM) are analyzed using the ACSL. A magnetic equivalent circuit is based on the structure of the HLSM, and then the electric equivalent circuit of the HLSM is derived by solving equations for the magnetic equivalent circuit. A normal force is calculated using FEM(Flux2D). And the vibration characteristics(Continuous vibration) of the HLSM are simulated by the ACSL with the voltage equations, the thrust equation, the normal force equation and the kinetic equation.

  • PDF

An LED Drive Circuit and it's Protection Circuit (LED 구동회로의 보호회로)

  • Park, Yu-Cheol;Kim, Hoon;Kim, Hee-Jun;Chae, Gyun;Kang, Eui-Byoung
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1063-1064
    • /
    • 2008
  • In this paper, two kinds of the protection circuits are proposed and simulated to verify their performances. One is an over current protection circuit, and the other is a no load protection circuit which reduces power consumption. These protection circuits of an LED drive circuit can reduce power consumption and prevent to damage the elements.

  • PDF

Critical Short Circuit Ratio Analysis on DFIG Wind Farm with Vector Power Control and Synchronized Control

  • Hong, Min;Xin, Huanhai;Liu, Weidong;Xu, Qian;Zheng, Taiying;Gan, Deqiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.320-328
    • /
    • 2016
  • The introduction of renewable energy sources into the AC grid can change and weaken the strength of the grid, which will in turn affect the stability and robustness of the doubly-fed induction generator (DFIG) wind farm. When integrated with weak grids, the DFIG wind turbine with vector power control often suffers from poor performance and robustness, while the DFIG wind turbine with synchronized control provides better stability. This paper investigates the critical short circuit ratios of DFIG wind turbine with vector power control and synchronized control, to analyze the stability boundary of the DFIG wind turbine. Frequency domain methods based on sensitivity and complementary sensitivity of transfer matrix are used to investigate the stability boundary conditions. The critical capacity of DFIG wind farm with conventional vector power control at a certain point of common coupling (PCC) is obtained and is further increased by employing synchronized control properly. The stability boundary is validated by electromagnetic transient simulation of an offshore wind farm connected to a real regional grid.

Simulation and Parameter Identification of Induction Machine in Load Modeling based on the Static Circuit Analysis (정태회로해석에 의한 전력부하로서의 유도전동기 시뮬레이션 및 파라메터 식별)

  • Lee, Bong-Yong;Shim, Keon-Bo;Ko, Tae-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.370-374
    • /
    • 1991
  • This paper presents a static circuit model for static ant dynamic simulation of induction motors and identification of motor parameters. Instead of usual T-circuits, equivalent ${\pi}$-circuit has been proposed so that power Inputs into motor terminals can very easily calculated with very well known load flow method. It has been shown that, with wide range variation of applied voltage and frequency, successful static simulations can be performed and further the proposed static model can be used to simulate dynamic characteristics. Finally it is shown also that motor parameters can easily be identified based on the proposed static circuit.

  • PDF

A Study on the Wiring Control Method of Hand & Auto Operation of an Easy Elevator (간이 승강기 수·자동 배선제어방식에 관한 연구)

  • 위성동;구할본
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.4
    • /
    • pp.351-357
    • /
    • 2003
  • An easy learning elevator originated is opened to compare the existed teaming equipment, and it had a high studied efficiency that the sequence control circuit can open and close with the wire. The structure of equipment to be controlled from the first floor to the fifth floors is demostrated by the constructive apparatus with the lamps to express the function of the open-close of the door according to the cage moving with a mechanical actuation of the forward reverse breaker and the motor of load, and the mechanical actuation of hand-operation control components of push-button S/W and L/S and relay etc. These components let connect each other in order to control of the elevator function with the auto program and the designed sequence control circuit. Consequently the cage could go and come till 1∼5 steps with an auto program of the elevator and the sequence control circuit. The sequence control circuit is controlled by the step of forward and reverse to follow as that the sensor function of L/S1 ∼ L/S5 let posit with the control switchs of S/W1 ∼ S/W5 of PLC testing panel and switchs of S/W1 ∼ S/W5 installed on the transparent acryl plate of the frame. In here, improved apparatus is the hand-auto operation combined learning equipment to study the principle and technique of the originate sequence control circuit and the auto program of PLC.

EMC Performance Improvement of Distribution Automation Circuit-Breaker by Modified Installing Method of Control Cable (제어케이블의 설치기법 개선에 의한 배전자동화용 개폐기의 EMC 성능 향상)

  • 김언석;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.60-67
    • /
    • 2003
  • The goal of this paper is to improve EMC performance of circuit breaker. Circuit breaker and control cubicle are interconnected by multi control cable. Also many control cables are laid on each apparatus. These control cables are directly connected by electronic components. So control cables are very important to improve EMC performance of circuit breaker. This paper suggests installing a ground conductor in parallel(PGC) to control cables. Also this paper suggests using shielding cables as secondary cables of voltage transformer in circuit breakers, and grounding both ends of shielding. After applying suggested methods, we verified EMC performance of circuit breaker is improved.

A Study on the control of Power Factor Correction Circuit by Advanced Average Current Control (개선된 평균 전류 제어 방식 역률 개선 회로의 제어에 관한 연구)

  • Kim, Tae-Kue;Kim, Tae-Woo;Choi, Hyun-Eui;Kim, Min-Chan;Ahn, Ho-Kyun;Yoon, Tae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.999_1000
    • /
    • 2009
  • The purpose of this paper is a study on the control of Power Factor Correction circuit by advanced average current control. The international standard organizations have made an effort to resolve these problems caused by the harmonics and announced the international standards for limiting the harmonic currents of the electrical devices and products. For improving power factor and reducing harmonics, many studies are progressed rapidly. In this study, we explain a method of an advanced average current control. And then, the performances of the PFC circuit applying a advanced average current control method are simulated and verified by Matlab/Simulink.

  • PDF

An LED Lighting with Varying Color Temperature for Emotional Lighting Systems (감성조명 시스템을 위한 색온도 조정 가능한 LED 조명)

  • Liu, Jia;Kim, Hoon;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.522-523
    • /
    • 2008
  • This paper presents an LED lighting which can control its color temperature. It consists of a power factor correction (PFC) circuit, an LED driver, and an LED color control circuit. The proposed system can adjusts the light intensity to obtain a desired color with independently changeable illuminance. The power factor of the PFC circuit is 98%. The LED driver has 90% efficiency at 300mA output current. The output power of the experimented LED lighting is 150 W. The achieved color temperature range was from 3000K to 7500K, and the illumination one was from 500 lux to 1500 lux.

  • PDF

Two Paralleled Four Quadrant DC Chopper for Gradient Coil Magnetic Fields in MRI System

  • Park, Hyung-Beom;Mun, Sang-Pil;Park, Han-Seok;Woo, Kyung-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.11
    • /
    • pp.22-27
    • /
    • 2009
  • This paper presents a two-paralleled four quadrant DC chopper type PWM power conversion circuit in order to generate a gradient magnetic field in the Magnetic Resonance Imaging (MRI) system. This circuit has 8-IGBTs at their inputs/outputs to realize further high-power density, high speed current tracking control, and to get a low switching ripple amplitude in a controlled current in the Gradient Coils (GCs). Moreover, the power conversion circuit has to realize quick rise/fall response characteristics in proportion to various target currents in GCs. It is proposed in this paper that a unique control scheme can achieve the above objective DSP-based control system realize a high control facility and accuracy. It is proved that the new control system will greatly enlarge the diagnostic target and improve the image quality of MRI.