• 제목/요약/키워드: electrical arc furnace

검색결과 44건 처리시간 0.04초

과도현상 해석을 위한 EAFs 부하 무델의 개발 (An Electric Arc Furnaces Load Model for Transient Analysis)

  • 장길수;;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권3호
    • /
    • pp.197-202
    • /
    • 1999
  • Electric arc furnaces (EAFs) use bulk electrical energy to create heat in metal refining industries. The electric arc process is a main cause of the degradation of the electric power quality such as voltage flicker due to the interaction of the high demand currents of the load with the supply system impedance. The stochastic models have described the aperiodic physical phenomena of EAFs. An alternative approach is to include deterministic chaos in the characterization of the arc currents. In this parer, a chaotic approach to such modeling is described and justified. At the same time, a DLL(Dynamic Link Library) module, which is a FORTRAN interface with TACS (Transient Analysis of Control Systems), is developed to implement the chaotic load model in the Electromagnetic Transients Program (EMTP). The details of the module and the results of tests performed on the module to verify the model and to illustrate its capabilities are presented in this paper.

  • PDF

동시부하율을 고려한 전기로의 수요관리 잠재량 산출 (Calculation of DSM's Latent capacity for arc-furnace Considered with the Same Time Load Factor)

  • 손학식;김인수;임상국;김형중;허동렬;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.82-84
    • /
    • 2004
  • This paper has calculated DSM's latent capacity through a survey investigating electric arc furnaces in over 2,000 toe companies and related organizations. The latent capacity of DSM calculated with the same time load factor is considered in this paper. The time load factor depends on the probability of each electric arc furnace of the value to work and the consideration of experts and technician's experience. Also, this paper verifies the reliability and application of unposed capacity which compared the old latent capacity of Load Management with KEMCO and KEPCO's Direct Load Control gathering capacity.

  • PDF

시간에 따라 변하는 전기로 부하의 고조파 측정, 평가 및 시뮬레이션에 관한 연구 (A Study on the Time-varying Harmonics Measurement, Assessment and Simulation of the Electric Arc Furnace Loads)

  • 김경철;진성은;이주홍;전영수
    • 조명전기설비학회논문지
    • /
    • 제20권5호
    • /
    • pp.9-17
    • /
    • 2006
  • 규모가 큰 제철소는 전기로와 같은 비선형 부하를 가지고 있다. 고조파 측정 결과로 고조파는 시간에 따라 변하는 특성이 관측되었다. 순시치 측정에 의한 고조파 평가는 측정 순간에 따라 고조파가 다를 수 있으므로 모호한 결과를 초래할 수 있다. 시간에 따라 변하는 고조파를 해결하기 위해 쓰이는 가장 보편적인 방법은 누적확률을 사용하는 것이다. 고조파 시뮬레이션은 사례연구 시스템의 전압 및 전류 왜곡을 평가하기 위해 이용되었다. 본 논문에서는 전기로 부하의 고조파 현장 측정, 국제 고조파 관리 기준인 IEC 61000-3-6과 IEEE Std. 519에 의한 고조파 평가, 시간에 따라 변하는 고조파의 시뮬레이션을 심도 있게 다루고자 한다. 고조파 해석 프로그램인 EDSA는 사례 연구에 시뮬레이션 도구로 사용되었다.

전기로 부하에서 SVC의 고조파 및 플리커 효과에 관한 연구 (A Study on the Harmonic and Flicker Effects of SVC in Electric Arc Furnace Loads)

  • 김경철;최형범;오정석
    • 조명전기설비학회논문지
    • /
    • 제21권10호
    • /
    • pp.150-158
    • /
    • 2007
  • 규모가 큰 제철소는 전기로를 포함한 시간에 따라 변하는 비선형 부하를 가지고 있다. 이들 비선형 부하는 고조파 전류를 발생시키고, 전력계통의 전압을 왜곡시킨다. 플리커는 전압 변동의 크기에 따라 램프의 방출 변화에 의한 인간의 지각 효과로 정의된다. SVC의 주 목적은 공통결합점에서 전압을 한계값 이하로 유지하는데 있다. 본 논문에서는 SVC 투입 전후의 고조파와 플리커 저감 효과를 분석하고, IEC 61000-3-6과 IEC 61000-3-7에 의해 평가하였다.

실측에 의한 특고압 수용가의 고조파 평가에 관한 연구 (A Study on the Harmonics Evaluation of Extra High Voltage Customers by Field Tests)

  • 김경철;김유준
    • 조명전기설비학회논문지
    • /
    • 제21권3호
    • /
    • pp.50-55
    • /
    • 2007
  • 전기로를 포함하는 비선형 부하를 가진 규모가 큰 제철소는 특고압 수용가이다. 이득 비선형 부하는 고조파 전류를 발생시키고, 전력계통의 전압을 왜곡시킨다. 고조파 측정결과로 고조파는 시간에 따라 변하는 특성을 가지고 있었다. 시간에 따라 변하는 고조파를 해결하기 위해 쓰이는 가장 보편적인 방법은 누적확률을 사용하는 것이다. 본 논문에서는 전기로 부하의 시간에 따라 변하는 고조파를 국제 고조파 기준인 IEC 61000-3-6, IEEE 519와 JIS C 61000-3-2에 의해 평가하고자 한다.

실측치에 의한 전기아크로 고조파 해석 모델 개발 (Development of Electric Arc Furnace Model for Harmonic Analysis Using Measuring Data)

  • 오동환;장길수;이강완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.298-301
    • /
    • 2001
  • This paper describes development of electric are furnace model for harmonic analysis, which is based on field data. The proposed model is used to analyze harmonics in actual power system, and the results illustrate the model's capabilities.

  • PDF

The influence of EAF dust on resistivity of concrete and corrosion of steel bars embedded in concrete

  • Almutlaq, Fahad M.
    • Advances in concrete construction
    • /
    • 제2권3호
    • /
    • pp.163-176
    • /
    • 2014
  • Essentially, when electrical current flows easily in concrete that has large pores filled with highly connective pore water, this is an indication of a low resistivity concrete. In concrete, the flow of current between anodic and cathodic sites on a steel reinforcing bar surface is regulated by the concrete electrical resistance. Therefore, deterioration of any existing reinforced concrete structure due to corrosion of reinforcement steel bar is governed, to some extent, by resistivity of concrete. Resistivity of concrete can be improved by using SCMs and thus increases the concrete electrical resistance and the ability of concrete to resist chloride ingress and/or oxygen penetration resulting in prolonging the onset of corrosion. After depassivation it may slow down the corrosion rate of the steel bar. This indicates the need for further study of the effect of electric arc furnace dust (EAFD) addition on the concrete resistivity. In this study, concrete specimens rather than mortars were cast with different additions of EAFD to verify the electrochemical results obtained and to try to understand the role of EAFD addition in influencing the corrosion behaviour of reinforcing steel bar embedded in concrete and its relation to the resistivity of concrete. The results of these investigations indicated that the corrosion resistance of steel bars embedded in concrete containing EAFD was improved, which may link to the high resistivity found in EAFD-concrete. In this paper, potential measurements, corrosion rates, gravimetric corrosion weight results and resistivity measurements will be presented and their relationships will also be discussed in details.

Development of Matlab/Simulink Module for Voltage Flicker Simulation in Distribution Power Systems

  • Cho, Soo-Hwan;Jung, Jae-Ahn;Jang, Gil-Soo;Kwon, Sae-Hyuk;Kang, Moon-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권3호
    • /
    • pp.314-319
    • /
    • 2008
  • Power quality simulation plays an important role in many practical cases, for example, when deciding the capacity of the related mitigation devices, assessing the influence of installing a nonlinear load in the distribution part, dissolving the quality issues between utilities and customers, and so on. For these purposes, many dedicated tools have been used in order to assess the level of quality distortions by various kinds of PQ indices. However, there are few modules that can accurately simulate the flicker phenomenon, that is, $P_{st}$ and the nonlinear and chaotic behavior of the electrical arc furnace, which is one of the representative nonlinear loads. This paper deals with the useful and simple modules for the voltage flicker simulation in the distribution and transmission level under the environment of Matlab/Simulink. With these modules, the various conditions of distribution systems and the capacities of arc furnaces with the chaotic characteristic can be easily taken into account.

전력 품질 해석을 위한 개선된 전기아크로 모델 개발 (Development of a Chaotic Electric Arc Furnace Model)

  • 장길수;;이병준;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.55-57
    • /
    • 2000
  • 대규모의 전력을 사용하며 전력 수요가 일정하지 않고 변동하는 제철소의 전기아크로 (electric arc furnace) 부하는 전압 플릭커 (voltage flicker) 등 전력품질을 저하시키는 현상의 주 원인이 되고 있다. 따라서, 전력품질의 향상을 위한 전력계통의 계획과 운용에 있어서 이러한 부하들의 비선형적인 전압-전류 특성을 해석하고 모델링하는 것이 우선 되어야 한다. 특히 전기아크로 부하의 비선형적이고 랜덤 신호에 가까운 특성은 stochastic 접근법에 의해 주로 모델링되어 왔으나, 전기아크로 부하에 의한 전력계통에서의 영향을 평가를 위해서는 deterministic 접근법에 의한 모델링이 필요하며 전기아크로 부하가 가지는 chaos 특성을 Lorenz 시스템으로 표현한 부하모델이 개발되었다[1]. 개발된 모델에 의해 하나의 chaos 시스템으로 예측된 전기아크로 부하 패턴은 전 동작 범위에서 부하 특성을 정확하게 반영하는데 문제가 있다. 따라서, 전기아크로 부하 패턴을 표현할 수 있는 복수의 chaos 시스템을 이용하여 보다 나은 예측 특성을 가진 부하 모델의 개발이 필요하다. 본 논문에서는 기존의 Lorenz 시스템과 전기아크로 부하의 고주파영역 특성을 보다 적절하게 반영할 수 있는 Logistic 시스템을 혼합한 형태의 chaos 모델을 개발하고, 전력 계통에서의 전력품질 저하현상을 정량화하는 지수를 통해 모델의 유용성과 정확성을 검증하고자 한다.

  • PDF

MLR & ANN approaches for prediction of compressive strength of alkali activated EAFS

  • Ozturk, Murat;Cansiz, Omer F.;Sevim, Umur K.;Bankir, Muzeyyen Balcikanli
    • Computers and Concrete
    • /
    • 제21권5호
    • /
    • pp.559-567
    • /
    • 2018
  • In this study alkali activation of Electric Arc Furnace Slag (EAFS) is studied with a comprehensive test program. Three different silicate moduli (1-1,5-2), three different sodium concentrations (4%-6%-8%) for each silicate module, two different curing conditions (45%-98% relative humidity) for each sodium concentration, two different curing temperatures ($400^{\circ}C-800^{\circ}C$) for each relative humidity condition and two different curing time (6h-12h) for each curing temperature variables are selected and their effects on compressive strength was evaluated then regression equations using multiple linear regressions methods are fitted. And then to select the best regression models confirm with using the variables, the regression models compared between itself. An Artificial Neural Network (ANN) models that use silicate moduli, sodium concentration, relative humidity, curing temperature and curing time variables, are formed. After the investigation of these ANN models' results, ANN and multiple linear regressions based models are compared with each other. After that, an explicit formula is developed with values of the ANN model. As a result of this study, the fluctuations of data set of the compressive strength were very well reflected using both of the methods, multiple linear regression with quadratic terms and ANN.