• 제목/요약/키워드: electric wire

검색결과 744건 처리시간 0.028초

전기기계식 배터리 시스템용 초고속 전동발전기의 설계, 제작 및 모드별 특성 (Design, Manufacture and Performance Characteristics under Each Mode of High-Speed Motor/Generator for Electro-Mechanical Battery System)

  • 장석명;서진호;정상섭;최상규;함상용
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권8호
    • /
    • pp.400-407
    • /
    • 1999
  • This paper treated the design, manufacture and the performance characteristics under each mode of high speed motor/generator for an electro-mechanical battery(EMB). This machine is employed as an integral part of a flywheel energy storage system(FESS), i.e., a modular flywheel system to be used as a device for storing electrical or mechanical energy. In this machine, the magnetic field system is constructed by using special magnet array, dipole Halbach array with 16 permanent magnet segments and the armature is composed of a plastic bobbin and multi-phase windings with Litz wire. The magnet array produces a highly uniform dipole field without back iron. The motor/generator is 3-phase machine in which the dipole Halbach array surrounding the winding is rotating. Since there are no iron laminations, this field system offers some unique advantages for the simplicity of the design and the theoretical prediction of characteristics of a high speed electric machine. This paper describes the results obtained when EMB system was tested in the laboratory.

  • PDF

Insert dewar를 이용한 초전도 MRI 마그네트의 자장분포 평가 (Magnetic Field Distributions of Superconducting MRI Magnet in Insert Dewar)

  • 진홍범;오봉환;권영길;오상수;조전우;하동우;이언용;류경우;류강식;한일용;나완수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.137-140
    • /
    • 1995
  • This paper describes the test results of magnetic field distributions of superconducting MRI magnet in an insert dewar. To get a very high homogeneous magnetic field, various shim coils are installed besides the main magnet. The operating currents of each shim coils are obtained from the exact measurements of the magnetic field. In this paper, we report the test results of the magnetic field distribution measurements with various shim coils.

  • PDF

철도교량의 종방향 동적 변위에 따른 전차선로 장력조정장치 거동특성에 관한 연구 (A Study on the Behavior Characteristics of a Tensioning Device of a Catenary System According to the Longitudinal Dynamic Displacement of Railroad Bridge)

  • 나연일;이재봉;김재문;김양수
    • 전기학회논문지
    • /
    • 제64권10호
    • /
    • pp.1517-1522
    • /
    • 2015
  • Since electric railroad vehicle pass through repeatedly on the railroad bridge, the dynamic load that causes the change of tension of contact wire affect it constantly. In this paper, we measured the dynamic displacement of the railroad bridges to analyze the effect of tension in the catenary. A result of dynamic measurement of the longitudinal displacement, it's maximum value was 39.9mm which was lower than the primary management criteria 378mm. Also on the based of a maximum temperature, it shows a feature that the longitudinal displacement value increased as temperature rise from April to October. In terms of behavior characteristics of a tensioning device, it was confirmed to be the value of 50mm stroke movement when the temperature changes ±5℃.

차폐층을 갖는 다층고온초전도 전력케이블의 전류분류 분석 (Analysis of Current Distribution of Multi-Layer HTSC Power Cable with a Shield Layer)

  • 이종화;임성훈;고석철;박충렬;한병성;황시돌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.535-538
    • /
    • 2004
  • Superconducting transmission power cable is one of interesting parts in power application using high temperature superconducting wire. One of important parameters in high-temperature superconduting (HTSC) cable design is transport current distribution because it is related with current transmission capacity and AC loss. In this paper, the transport current distribution at conducting layers was investigated through the analysis of the equivalent circuit for HTSC power cable with shield layer and compared with the case of without shield layer. The transport current distribution due to the pitch lenght was improved in the case of HTSC power cable with shield layer from the analysis.

  • PDF

전선 직경 변화에 따른 단락 아크 특성에 관한 연구 (A Study on the Arc Characteristics of Wires During a Short-Circuit by the Diameter)

  • 김영석;송길목;김동욱;김동우;최충석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.495-498
    • /
    • 2004
  • In this paper, the arc and flame characteristics of wires were studied during a short-circuit. The short-circuit angle between wires was fixed as $90^{\circ}$ and the experiments were conducted on bare copper wires by varying the diameter of wires. The arc and flame patterns were taken by a high speed imaging system. The direction of arc and flame was explained with Lorentz force. After the short-circuit experiment, the shapes of molten wires were analyzed by a stereo microscope. In the results of experiment, the arc and flame of wires showed particular patterns. The flame characteristics by the diameter of wires were analyzed using a HSIS. We could find out the arc characteristics of wires which were different by the diameter.

  • PDF

염류집적 농경지 탈염을 위한 전기역학적 처리공정의 비용산출 (Cost Analysis of Electrokinetic Process for Desalination of Saline Agricultural Land)

  • 김도형;최정희;조성웅;백기태
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제17권4호
    • /
    • pp.91-97
    • /
    • 2012
  • In this study, cost analysis of electrokinetic (EK) restoration process for desalination of saline agricultural land was performed for field application based on a pilot scale field application. For reasonable cost analysis, EK process was classified into three major parts: system design, installation and operation. Cost of system installation consists of materials and installation for electrode/electric wire, power supply and data monitoring, drainage system, etc. Operation cost was calculated based on electrical consumption and water charges for EK process. Total cost for EK process was 2,943,013 won for $1000m^2$ in greenhouse area. Cost for system installation was 2,553,786 won, that is, 87% of total cost, while cost for system operation was 389,229 won, that is, 13% of total cost.

Current Measurement and Velocity Spatial Distribution of Deep Ocean Engineering Basin

  • Jung, Sung-Jun;Jung, Jae-Sang;Lee, Yong-Guk;Park, Byeong-Won;Hwang, Sung-Chul;Park, In-Bo;Kim, Jin-Ha;Park, Il-Ryong
    • 한국해양공학회지
    • /
    • 제35권2호
    • /
    • pp.150-160
    • /
    • 2021
  • To ensure the international competitiveness of the domestic offshore plant industry, a consensus has been formed regarding the requirement for large offshore basins for performing offshore plant performance verification. Accordingly, the Korea Research Institute of Ships & Ocean Engineering has built the world's largest deep ocean engineering basin (DOEB). The purpose of this study is to evaluate the characteristics of velocity distribution under various conditions of the DOEB. An independent measuring jig is designed and manufactured to measure the current velocities of many locations within a short time. The measurement jig is a 15-m-high triangular-truss structure, and the measurement sensors can move 15 m vertically through an electric motor-wire device. The current speed is measured under various impeller revolutions per minute and locations of the DOEB using the jig. The spatial distribution characteristics of the current velocity in the DOEB and the performance of the current generator are analyzed. The maximum speed is 0.56 m/s in the center of the DOEB water surface, thereby confirming sufficient current velocity distribution uniformity for model testing.

보강성 충진제를 첨가한 실리콘 고무의 난연 및 화재안전 특성에 관한 연구 (A Study on the Properties of Flame Retardant and Fire Safety of Silicone Rubbers Added Reinforcing Fillers)

  • 박승호;이성일
    • 한국전기전자재료학회논문지
    • /
    • 제32권4호
    • /
    • pp.349-355
    • /
    • 2019
  • A fire, be it caused intentionally or unintentionally, leads to economic loss and physical damage, and requires digestion. The number of fires is increasing yearly, and electrical fires account for more than 30% among the main causes of fires. Electric wires that catch fire typically employ silicone coatings; silicone has organic as well as inorganic properties. Silicon is a natural, nonexistent, synthetic product with numerous applications. In this study, a silicon rubber for application in wires was prepared by high-temperature vulcanization (HTV) with a Shore A hardness of 70. We report results for the flame retardancy test and the fire safety characteristics via inorganic analysis. For this, a quartz inorganic material was added to the wire specimen, and 18% powdered extinguishing agent ammonium phosphate and expanded vermiculite respectively. Thus, expanded vermiculite showed the best flame retardancy and fire safety characteristics.

Transmission Lines Rights-of-Way Mapping Using a Low-cost Drone Photogrammetry

  • Oh, Jae Hong;Lee, Chang No
    • 한국측량학회지
    • /
    • 제37권2호
    • /
    • pp.63-70
    • /
    • 2019
  • Electric transmission towers are facilities to transport electrical power from a plant to an electrical substation. The towers are connected using wires considering the wire tension and the clearance from the ground or nearby objects. The wires are installed on a rights-of-way that is a strip of land used by electrical utilities to maintain the transmission line facilities. Trees and plants around transmission lines must be managed to keep the operation of these lines safe and reliable. This study proposed the use of a low-cost drone photogrammetry for the transmission line rights-of-way mapping. Aerial photogrammetry is carried out to generate a dense point cloud around the transmission lines from which a DSM (Digital Surface Model) and DTM (Digital Terrain Model) are created. The lines and nearby objects are separated using nDSM (normalized Digital Surface Model) and the noises are suppressed in the multiple image space for the geospatial analysis. The experimental result with drone images over two spans of transmission lines on a mountain area showed that the proposed method successfully generate the rights-of-way map with hazard nearby objects.

냉동차량을 위한 온도 측정 시스템 (Temperature Measurement System for Refrigerated Vehicle)

  • 임용진;김정환;임준홍
    • 전기전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.159-163
    • /
    • 2019
  • 최근 생활수준의 향상으로 외식문화가 발전하고 있고 온라인과 오프라인으로도 냉동식품의 택배수요가 날로 증가하고 있다. 현재 이러한 식품유통의 대부분은 냉동차량에 의해서 이루어지고 있다. 냉동차량에서 가장 중요한 요소 중에 하나는 정확히 온도를 측정하는 것이다. 기존의 상용 온도 기록 시스템은 일반적으로 온도 센서 모듈을 기록계에 직접 연결하는 형태이다. 이러한 기존의 방법은 전선을 사용하여 기록계에 온도 데이터를 전송하기 때문에 케이블의 길이에 따라 저항 오차를 보상해야한다. 본 논문은 케이블 내의 저항으로 인해 발생하는 오차를 극복하기 위해서 디지털 처리와 CAN (Controller Area Network) 통신을 사용하는 것을 제안한다. 또한 온도 측정의 정확도를 높이기 위해서 백금 센서인 PT-1000을 사용한다.