• 제목/요약/키워드: electric wave

검색결과 797건 처리시간 0.028초

아크사고 발생 시 전압 왜형파를 이용한 아크차단기 개발 (Development of Arc Fault Circuit Interrupter Using the Distorted Voltage Wave in Electric Arc Faults)

  • 곽동걸
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.876-880
    • /
    • 2013
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The principal factor of the fire is electric arc or spark accompanied with such electric faults. Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB), that is, Residual Current Protective Devices (RCDs) used on low voltage distribution lines cut off earth leakage and overload, but the RCD can not cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied in low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To improve such problems, this paper studies on an arc fault circuit interrupter (AFCI) using the distorted voltage wave in electric arc faults. The proposed voltage sensing type AFCI is an electrical fire prevention apparatus of new conception that operates a circuit breaker with sensing the instantaneous voltage drop of line voltage at electrical faults occurrence. The proposed AFCI is composed of control circuit topology using some semiconductor switching devices. Some experimental tests of the proposed AFCI confirm practicality and the validity of the analytical results.

유도초음파를 이용한 장거리 배관 탐상기법 (Long Range Ultrasonic Guided Wave Techniques for Inspection of Pipes)

  • 박익근;김용권;김현묵;송원준;조용상;안연식
    • Journal of Welding and Joining
    • /
    • 제23권5호
    • /
    • pp.43-48
    • /
    • 2005
  • Conventional non-destructive techniques for inspection of the weld in pipelines require significant test time and high cost. Ultrasonic guided waves have been widely studied and successfully applied to various non-destructive tests with advantage of the long-range inspection. In this paper, a study on the application of ultrasonic guided waves to the long-range inspection of the pipeline is presented using a long-range guided wave inspection system, Wavemaker SE16, GUL. The characteristics and setup of the long-range guided wave inspection system and experimental results in pipes of with various diameter are introduced. The experimental results in mock-up pipes with cluster type detects show that the minimum detectable wall thickness reduction with this guided wave system is $2\~3\%$ in the pipe cross section area. And the wall thickness reduction of $5\%$ in cross section area can be detected when actual detection level is used. Therefore, the applicability of the guided wave systeme to long-range inspection of wall thickness reduction in pipes is verified.

Modeling and analysis of a cliff-mounted piezoelectric sea-wave energy absorption system

  • Athanassoulis, G.A.;Mamis, K.I.
    • Coupled systems mechanics
    • /
    • 제2권1호
    • /
    • pp.53-83
    • /
    • 2013
  • Sea waves induce significant pressures on coastal surfaces, especially on rocky vertical cliffs or breakwater structures (Peregrine 2003). In the present work, this hydrodynamic pressure is considered as the excitation acting on a piezoelectric material sheet, installed on a vertical cliff, and connected to an external electric circuit (on land). The whole hydro/piezo/electric system is modeled in the context of linear wave theory. The piezoelectric elements are assumed to be small plates, possibly of stack configuration, under a specific wiring. They are connected with an external circuit, modeled by a complex impedance, as usually happens in preliminary studies (Liang and Liao 2011). The piezoelectric elements are subjected to thickness-mode vibrations under the influence of incident harmonic water waves. Full, kinematic and dynamic, coupling is implemented along the water-solid interface, using propagation and evanescent modes (Athanassoulis and Belibassakis 1999). For most energetically interesting conditions the long-wave theory is valid, making the effect of evanescent modes negligible, and permitting us to calculate a closed-form solution for the efficiency of the energy harvesting system. It is found that the efficiency is dependent on two dimensionless hydro/piezo/electric parameters, and may become significant (as high as 30 - 50%) for appropriate combinations of parameter values, which, however, corresponds to exotically flexible piezoelectric materials. The existence or the possibility of constructing such kind of materials formulates a question to material scientists.

Wave propagation induced by body forces for free microtubules using cylindrical shell model

  • Muhammad Taj;Ikram Ahmad;Mohamed Amine Khadimallah;Hamdi Ayed;Rana Muhammad Akram Muntazir;Abir Mouldi;Manahil Maqsood;Essam Mohammed Banoqitah;Muzamal Hussain;Abeera Talib;Hajra Khanam;Zafer Iqbal
    • Advances in concrete construction
    • /
    • 제17권2호
    • /
    • pp.67-73
    • /
    • 2024
  • This paper examines the wave velocity of protein microtubules using a elasticity model that incorporates body forces, based on the structure of these hollow cylinder-like structures., the governing equations are analytically solved to determine how the body forces effect the wave velocity. To analyze the microtubule waves velocity, use microtubules with simply supported ends. The electric field of a dipole vibrating at the same frequency as microtubule vibrations approximates the electric field generated by the rhythmic motion of every charge. The numerical findings for the three modes of frequencies in the longitudinal, radial, and torsional directions for the current conditions are compared with the results of previous calculations.

Power Reflection and Transmission Coefficients for Meander-Line Polarizers with a Chiral Slab

  • Delihacioglu, Kemal;Uckun, Savas
    • ETRI Journal
    • /
    • 제25권1호
    • /
    • pp.41-48
    • /
    • 2003
  • This paper presents a theoretical investigation of power reflection and transmission coefficients for a meander-line polarizer placed periodically on a chiral slab. It is assumed that a linearly polarized transverse magnetic wave is incident on a chiral slab from the air region. In the analysis, we derive the electric and magnetic fields in the modal form in the air and chiral regions. We obtain power reflection and transmission coefficients in a straightforward manner after matching the tangential components of the electric and magnetic fields at the boundaries. We present numerical results for the power reflection and transmission coefficients versus frequency and incident angle for different values of the chirality admittance. A meander-line polarizer placed on a dielectric slab can convert a linearly polarized wave to a circularly polarized wave. The design parameters for a meander-line polarizer are the dimensions of the meander-line and the values of the dielectric slab. Replacing a dielectric slab with a chiral slab introduces a new independent parameter which controls the wave polarization.

  • PDF

2단계 침출 과정에서 발생되는 비산회로부터 초음파 활용하여 이트륨과 네오디뮴의 동시 추출 (Simultaneous Extraction of Yttrium and Neodymium from Fly Ash by Two-Step Leaching Process with Aid of Ultrasonic Wave)

  • Kim, Jae-Kwan;Park, Seok-Un
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권1호
    • /
    • pp.153-159
    • /
    • 2021
  • A two-step process for increasing the leaching efficiency of yttrium and neodymium from coal fly ash were investigated at solid loadings of 5.0 g ash ~1,000 g ash/l of 1.0 N~10.0 N H2SO4, temperature ranging from 30℃ to 90℃, ultrasonic leaching time of 1~10 hours, and ultrasonic power of 25~200 W. The yttrium and neodymium from coal fly ash were effectively leached into ion phases by step change of the first conventional dissolution at room temperature and then the second heating process with the aid of ultrasonic wave, and maximum leaching efficiency of yttrium and neodymium obtained were 66 % and 63 %, respectively. The activation energies for the leaching reaction of yttrium and neodymium at second heating process dependent on leaching time and temperature were derived to be 41.540 kJmol-1 and 507.92 kJmol-1, respectively. The optimum conditions for the maximum leaching of yttrium and neodymium were found to be the solid loading of 250 g ash/l of H2SO4, solvent concentration of 2.0 N H2SO4, and second step process of temperatures of 30℃ for 3 hours and then 90℃ for 4 hours with ultrasonic intensity of 100 W.

4개 변전소시설 부지 인근관측소의 지반증폭 특성 및 파형에너지 수준 비교 연구 (A Comparison Study of the Site Amplification Characteristics and Seismic Wave Energy Levels at the Sites near Four Electric Substations)

  • 유성화;김준경;위성훈
    • 한국지구과학회지
    • /
    • 제37권1호
    • /
    • pp.40-51
    • /
    • 2016
  • 실제 국내에서 관측된 가속도를 이용한 스펙트럼 값이 내진설계기준보다 상대적으로 크게 나타나는 경향을 보이며, 특히 고진동수 구간에서 국내 내진설계 기준이 국내 고유의 지반증폭 특성을 제대로 반영하지 못하고 있어 문제점이 많다고 지적되어 왔다. 지반증폭 특성을 분석할 때 여러 가지 방법이 제시되어 왔으며 본 연구는 현장에서 자주 적용되고 있는 지반진동의 수평/수직 스펙트럼 비율을 이용하는 방법을 적용하였다. 이 방법은 S파 및 레일리파를 이용하는 것으로부터 출발하였으나, 최근 Coda파 및 배경잡음 등에 확대 적용되어 지반의 동적인 증폭특성 연구에 많이 이용되고 있다. 제한된 연구 기간 동안 4개 변전소시설 관측소 각각 2개 지점(노두 및 시추공)에서 운영되었고 본 연구는 4개 관측소의 노두에서 동시에 관측된 3개 중규모 지진의 가속도 지반진동(S파, Coda파 및 배경잡음)을 이용하여 지반증폭을 분석하였다. 분석결과는 4개 관측소 각각에 대해 기존 연구결과인 시추공 지반증폭 특성과 상호 비교하였다. 또한 각각 관측소 및 지점에서 지반의 우월진동수를 이용하여 각각 지반에 대한 등급분류도 시도하였다. 각각의 지진관측소마다 저진동수 및 고진동수 특성, 관측소 고유의 우월진동수가 서로 상이하여 관측소 고유의 증폭특성을 보여주었다. 대다수 관측소는 S파, Coda파 및 배경잡음 에너지를 분석한 결과와 많은 부분이 유사함을 보여 주었다. 물론 본 연구로부터 도출된 결과를 다른 방법에 적용하여 얻어진 결과와 비교한다면 지반의 동적 특성 및 지반분류 연구에 많은 정보를 제시할 수 있다고 판단된다.