• Title/Summary/Keyword: electric survey

Search Result 436, Processing Time 0.032 seconds

Interference effect by underground utilities at electric resistivity Survey (전기비저항 탐사시 지하매설물에 의한 간섭효과 연구)

  • Kim, Jae-Hong;Oh, Byung-Hyun;Im, En-Sang;Lee, Jong-Wook
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.961-965
    • /
    • 2009
  • Using much electric resistivity survey to design or preservation administration of facilities. However, By survey method that electric resistivity survey grasps special quality in base by potential difference creating artificial current in underground, Is influenced in electric resistance propensitys of various underground utilities in base. This Study selects dam 1 place that could grasp well underground situation and studied electricity interference effect by effect of underground utilities. Grasp underground utilities of dam interior, and control and observed accuracy with survey wave because various pole space. Through this Study, wish to present survey method of electric resistivity survey at design or survey of preservation administration dimension after with drawn result.

  • PDF

Interference effect by electric utilities at electric resistivity Survey of fill dam (필댐의 전기비저항 탐사시 전기매체에 의한 영향 분석 연구)

  • Kim, Jae-Hong;Shin, Dong-Hoon;Im, En-Sang
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1037-1040
    • /
    • 2009
  • Using much most electricity electric resistivity survey by nondestructiveness inquiry enforcement design of country base equipment business and facilities preservation administration dimension electric resistivity survey sends and cause much effects in survey believability by electricity medium of survey personality survey contiguity that grasp base special quality by potential difference flowing current artificially in base. Is item that enforce in most in-suite although when make electric resistivity survey until present, electricity medium or effect research by electricity origination was gone much. There is shortcoming that must be difficult to know correct underground utilities establishment state in-suite in this research and do comparison examination running parallel drilling investigation to heighten believability of electric resistivity survey. Did to dam that censure data that regulate grading from construction and is censure construction which can know correctly interior base situation comparatively to electricity medium of interior and electricity eruption won of contiguity and base condition (base rock).

  • PDF

A Study on the Deep Structure of Yangsan Fault by Electric and Electromagnetic Surveys in Unyang and Bong-gye Areas, Kyeongnam Province, Korea (경상남도 언양 및 봉계리 지역에서의 전기, 전자탐사에 의한 양산단층의 심부구조 연구)

  • 손호웅;윤혜수;오진용
    • Economic and Environmental Geology
    • /
    • v.33 no.6
    • /
    • pp.525-536
    • /
    • 2000
  • Electromagnetic and electric surveys were performed to reveal the deep structure of the Yangsan fault in the Bong-gye and Unyang areas, Kyeongnam Province, Korea. Especially, high-frequency magnetotelluric (HFMT) method of EM survey was mainly employed to study the deep subsurface configuration of Yangsan fault. HFMT survey was performed at 25 points of spacing 50 m, making 1.3 km survey line in Unyang area and 13 points of spacing 50 m, making 0.6 km survey line in Bong-gye area. Two 2-D cross-sections (Unyang and Bong-gye areas) were achieved as results. Electric survey by dipole-dipole array was performed to study the structure of shallow subsurface and compare the results with HFMT surveys. The results of HFMT and electric surveys show that Yangsan fault is a geologic boundary. It is very narrow and steep (about $80^{\circ}C$), and extends to 1~1.5 km depth.

  • PDF

Survey and Analysis of Electric Power Use pattern in Industry (산업용 전력사용실태 조사분석)

  • Park, Jong-Jin;Rhee, Chang-Ho;Kim, Chang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.383-385
    • /
    • 2001
  • This paper presents electric power use pattern by end-use for each industry in Korea. Until now, the survey for industrial electric power use pattern by end-use has been sporadic and unsystematic. This paper presents the systematic survey and analysis for electric power use pattern by end-use. The major survey items include rate power and the number of equipments, and operation rate, etc. This paper will make good use of data base construction and policy for DSM.

  • PDF

A Study on New Geoelectric Survey and Instrumentation Using Low Frequency Electric Field Sensing Antenna (저주파 Electric Field Sensing Antenna를 이용한 새로운 탐사 및 계측에 관한 연구)

  • 배명수;여영호;손수국
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.427-430
    • /
    • 2002
  • This paper has been studied a new geoelectric survey and instrunmentation using Low Frequency Electric Field .sensing Antenna. “Low Frequency Electric Field Sensing” is a technology in new method of survey to use array type antenna, the power of operation in antenna is using AC or DC pulse instead of DC current. The architecture of system embodied transceiver system using a microprocessor(PIC) of Microcllip Technology Inc. An array antenna design and il control transmission of antenna to use CDMA in this system. It is using array type antenna for the earth、earth's crust to survey explain from theory and experience.

  • PDF

Forward Calculation of Electric Potential, Electric Field and Resistivity Survey on Anisotropic Layered Half Space (이방성 층상구조에 대한 전위와 전기장 및 전기비저항탐사 계산 연구)

  • Na, Sung-Ho;Kim, Hyoung-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.24 no.3
    • /
    • pp.98-112
    • /
    • 2021
  • We followed and extended the algorithm originally made by Das (1995) to calculate the electric potential and field induced by electric current in arbitrary anisotropic layered structure. We confirmed all the theoretical contents and coded the corresponding program to acquire the electric potential and field. Further we extended to forward estimation of apparent resistivity to be attained by electrical resistivity survey on anisotropic layered structure with differing the electrode spacing and azimuth of anisotropy. The effects of anisotropy were reviewed by considering some examples.

Investigation of Water Leakage in Seosan A-Region Sea Wall using Integrated Analysis of Remote Sensing, Electrical Resistivity Survey, Electromagnetic Survey, and Borehole Survey (원격탐사, 전기탐사, 전자기탐사 및 시추공영상의 융합적 분석을 통한 서산지역 방조제 누수구역 판별)

  • Hong, Seong-In;Lee, Dongik;Baek, Gwanghyun;Yoo, Youngcheol;Lim, Kookmook;Yu, Jaehyung
    • Economic and Environmental Geology
    • /
    • v.46 no.2
    • /
    • pp.105-121
    • /
    • 2013
  • This study introduces integrated approach on detection of a leakage in a sea wall based on remote sensing, electric resistivity survey, electromagnetic survey, and borehole survey for the Seosan A-Region sea wall. The satellite temperature distribution from Landsat ETM+ data identifies water leakage distribution and period by analyzing temperature mixing patterns between sea water and fresh water. Electric resistivity survey provides both horizontal and vertical anomaly distributions over the sea wall showing below average electric resistivity. Electromagnetic survey(electrical conductivity survey) reveals the potential possible leakage areas with minimal background impact by comparing electrical conductivity values between high and low tides. Borehole image processing system confirmed the locations of anomalies identified from the other survey methods and distributions of vertical fracture zones. The integrated approach identified 41.7% of the sea wall being the most probable area vulnerable to water leakage and effectively approximated both horizontal and vertical distribution of water leakage. The integrated analysis of remote sensing, electric resistivity survey, electromagnetic survey and borehole survey is considered to be an optimal method in identifying water leakage distribution, period, and extent of fractures knowledged from the boreholes.

The Study on Facility Accident Case and PL Recognition of the Safety Manager in Electric Installation for Private Use (자가용 전기설비 안전관리자의 PL인식 조사 및 사고사례 연구)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Sun-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.40-46
    • /
    • 2008
  • In this paper, we investigated electric safety manager's PL recognition and accident occurrence of electric power facilities in electric installation for private use. The target of questionnaire survey is 450 electric installations for private use, 154 responded the questionnaire among these and it occupied 35.8[%]. The questionnaire survey says that 58[%] of electric safety manager knew well about PL contents and 42[%] of them did not recognize its. 82.4[%] of them must applied PL law in electric installation, 5.8[%] of them did not need the PL law. Reason of PL application occupied 64[%] for stability of electrical facility and product, 19[%] for prevention of same accident. The accident of transformer occupied most and the power cable accident were much next. The questionnaire survey results, electric safety managers are interested in PL contents, they expected necessity of PL application about electrical accident strongly.

Deep structure of Ulsan fault by electric and EM surveys in ipsil area, South of Kyeongju (전기, 전자탐사에 의한 경주남부 (입실지역)의 울산 단층 심부구조)

  • 손호응
    • Economic and Environmental Geology
    • /
    • v.32 no.2
    • /
    • pp.161-167
    • /
    • 1999
  • Electric and electromagnetic surveys were conducted to investigate the deep structure of the Ulsan fault in Ipsil area, south of Kyeongju. On this study, especially high-frequency magnetotelluric method of electromagnetic survey in the frequency range of 10~100,000 Hz was mainly employed to study the deep subsurface configuration. High-frequency MT survey was performed at 70 points of spacing 30~50 m, making 3.8 km survey line. As a survey result, a 2-km-depth 2-D cross-section was achieved. It shows vertical and horizontal subsurface variations of resistivity values. Near-surface layer having low resistivity value becomes thicker eastward up to 800m. There is a steep low resistivity zone in the west side of survey line, and there exists two low resistivity zones dipping west in the east side of survey line. Two low resistivity zones are interpreted to be related to major movement pattern of the Ulsan fault. This suggests that major fault lines are developed on both peripheral sides of the broad fault zone.

  • PDF

Effect analysis by time passage after Repair & Reinforcement of Fill Dams (필댐 보수보강후 시간경과에 따른 효과 분석)

  • Kim, Jae-Hong;Oh, Byung-Hyun;Im, En-sang;Hong, Won-Pho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.697-703
    • /
    • 2008
  • Excessive water leakage phenomenon happens through damage of nation core zone of about 17,000 storage of water facilities or collapse of dam is worried, is being damaged or enforce dilapidated fill dam core zone's repair reinforcement. Example that use grouting method of construction considering construction and economic performance etc. recently by repair reinforcement way about defect of dam is increased. Permeation grouting method repair & reinforcement of fill dam countermeasure is preferred in nation. Do that is economical to decide these repair reinforcement effect and grouting effect estimation method that do not give damage to dam is effective. Therefore, observing electricity resistivity Survey change of dam since grouting reinforcement using Electric resistivity Survey inquiry of seismic survey method in this research, Wished to verify grouting effect whether is possible as Electric resistivity Survey, and study whether integrity of dam through repair reinforcement defined.

  • PDF