• 제목/요약/키워드: electric resistivity

검색결과 441건 처리시간 0.033초

전기, 전자탐사에 의한 경주남부 (입실지역)의 울산 단층 심부구조 (Deep structure of Ulsan fault by electric and EM surveys in ipsil area, South of Kyeongju)

  • 손호응
    • 자원환경지질
    • /
    • 제32권2호
    • /
    • pp.161-167
    • /
    • 1999
  • Electric and electromagnetic surveys were conducted to investigate the deep structure of the Ulsan fault in Ipsil area, south of Kyeongju. On this study, especially high-frequency magnetotelluric method of electromagnetic survey in the frequency range of 10~100,000 Hz was mainly employed to study the deep subsurface configuration. High-frequency MT survey was performed at 70 points of spacing 30~50 m, making 3.8 km survey line. As a survey result, a 2-km-depth 2-D cross-section was achieved. It shows vertical and horizontal subsurface variations of resistivity values. Near-surface layer having low resistivity value becomes thicker eastward up to 800m. There is a steep low resistivity zone in the west side of survey line, and there exists two low resistivity zones dipping west in the east side of survey line. Two low resistivity zones are interpreted to be related to major movement pattern of the Ulsan fault. This suggests that major fault lines are developed on both peripheral sides of the broad fault zone.

  • PDF

에폭시 복합재료의 전기적 특성에 미치는 나노 충진제의 영향 (Effect of Nano Filler on the Electrical Properties of Epoxy Composite)

  • 김정식;최현민;박희두;류부형;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.46-46
    • /
    • 2010
  • In this paper, we studied the volume resistivity and the electrical conductivity properties of nano composites to investigate the electrical properties of epoxy composites added nano MgO. The specimens were produced by classifying to 1.0, 3.0, 5.0, 10[wt%] and virgin specimen according to the addition amount of MgO. We measured the volume resistivity of nano filler using the High Resistance Meter(4329A) at the measuring temperature changed to 25, 50, 80, 100, and [$120^{\circ}C$]. As the result, it is confirmed that the volume resistivity was the highest stability and volume resistivity value is $2.6{\times}10^{17}\;[\Omega{\cdot}cm]$ at 3.0[wt%]. And it is confirmed that the electrical conductivity property is sharply increased at low electric filed region and the conductivity current density is rapidly increased at high electric filed region.

  • PDF

Electrical Properties and Microstructures in Ti Films Deposited by TFT dc Sputtering

  • Han, Chang-Suk;Jeon, Seung-Jin
    • 한국재료학회지
    • /
    • 제26권4호
    • /
    • pp.207-211
    • /
    • 2016
  • Ti films were deposited on glass substrates under various preparation conditions in a chamber of two-facing-target type dc sputtering; after deposition, the electric resistivity values were measured using a conventional four-probe method. Crystallographic orientations and microstructures, including the texture and columnar structure, were also investigated for the Ti films. The morphological features, including the columnar structures and surface roughness, are well explained on the basis of Thornton's zone model. The electric resistivity and the thermal coefficient of the resistivity vary with the sputtering gas pressure. The minimum value of resistivity was around 0.4 Pa for both the $0.5{\mu}m$ and $3.0{\mu}m$ thick films; the apparent tendencies are almost the same for the two films, with a small difference in resistivity because of the different film thicknesses. The films deposited at high gas pressures show higher resistivities. The maximum of TCR is also around 0.4 Pa, which is the same as that obtained from the relationship between the resistivity and the gas pressure. The lattice spacing also decreases with increasing sputtering gas pressure for both the $0.5{\mu}m$ and $3.0{\mu}m$ thick films. Because they are strongly related to the sputtering gas pressures for Ti films that have a crystallographic anisotropy that is different from cubic symmetry, these changes are well explained on the basis of the film microstructures. It is shown that resistivity measurement can serve as a promising monitor for microstructures in sputtered Ti films.

Roles of Nickel Layer Deposition on Surface and Electric Properties of Carbon Fibers

  • Kim, Byung-Joo;Choi, Woong-Ki;Bae, Kyong-Min;Moon, Cheol-Whan;Song, Heung-Sub;Park, Jong-Kyoo;Lee, Jae-Yeol;Im, Seung-Soon;Park, Soo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권5호
    • /
    • pp.1630-1634
    • /
    • 2011
  • Electroless plating of metallic nickel on carbon fiber surfaces was carried out to control specific electric resistivity of the fibers, and the effects of the nickel content and coating thickness on the electric properties were studied. The structural and surface properties of the carbon fibers were characterized using X-ray diffraction (XRD), scanning electron microscopy (SEM), and X-ray photoelectron spectroscopy (XPS). The specific resistivity of the fibers was measured using a four-point probe testing method. From the XPS results, the oxygen and Ni atomic ratio of the fibers was greatly enhanced as the plating time increased. Additionally, it was observed that the specific electric resistivity decreased considerably in the presence of metallic nickel particles and with the formation of nickel layers on carbon fibers.

접지된 유전체층 위에 변하는 저항율을 갖는 저항띠 격자구조에서의 전자파산란 해석 -한쪽 모서리에서 0이고 다른쪽 모서리로 가면서 무한대로 변하는 경우- (Analysis of the Electromagnetic Scattering by a Resistive Strip Grating Tapered Resistivity On a Grounded Dielectric Plane -from Zeores at One Edge to Infinite at the Other Edge-)

  • 윤의중
    • 정보학연구
    • /
    • 제8권2호
    • /
    • pp.77-84
    • /
    • 2005
  • In this paper, electromagnetic scattering problems by a resistive strip grating with tapered resistivity on a grounded dielectric plane according to strip width and spacing, relative permittivity and thickness of dielectric layers, and incident angles of a electric wave are analyzed by applying the Fourier-Galerkin Moment Method known as a numerical procedure. The boundary conditions are applied to obtain the unknown field coefficients and the resistive boundary condition is used for the relationship between the tangential electric field and the electric current density on the strip. The resistivity of resistive strips in this paper varies from zeroes at one edge to infinite at the other edge, then the induced surface current density on the resistive strip is expanded in a series of Jacobi polynomials of the order ${\alpha}=0.2,\;{\beta}=-0.2$ as a orthogonal polynomials. The numerical results of the geometrically normalized reflected power in this paper are compared with those for the existing perfectly conducting strip. The numerical results of the normalized reflected power for conductive strips case with zero resistivity in this paper show in good agreement with those of existing papers.

  • PDF

Testing of the permeability of concrete box beam with ion transport method in service

  • Wang, Jia Chun
    • Computers and Concrete
    • /
    • 제15권3호
    • /
    • pp.461-471
    • /
    • 2015
  • The permeability is the most direct indicator to reflect the durability of concrete, and the testing methods based on external electric field can be used to evaluate concrete permeability rapidly. This study aims to use an experiment method to accurately predict the permeability of concrete box beam during service. The ion migration experiments and concrete surface resistivity are measured to evaluate permeability of five concrete box beams, and the relations between these results in service concrete and electric flux after 6 hours by ASTM C1202 in the laboratory are analyzed. The chloride diffusion coefficient of concrete, concrete surface resistivity and concrete 6 hours charge have good correlation relationship, which denote that the chloride diffusion coefficient and the surface resistivity of concrete are effective for evaluating the durability of concrete structures. The chloride diffusion coefficient of concrete is directly evaluated permeability of concrete box beam in service and may be used to predict the service life, which is fit to engineering applications and the concrete box beam is non-destructive. The concrete surface resistivity is easier available than the chloride diffusion coefficient, but it is directly not used to calculate the service life. Therefore the mathematical relation of the concrete surface resistivity and the concrete chloride diffusion coefficient need to be found, which the service life of reinforced concrete is obtained by the concrete surface resistivity.

코어 비저항 측정에 미치는 영향요소에 대한 실험적 고찰 (Experimental Verification on Factors Affecting Core Resistivity Measurements)

  • 김영화;최예권
    • 지구물리
    • /
    • 제2권3호
    • /
    • pp.225-233
    • /
    • 1999
  • 암석의 비저항값은 암석 자체의 성질뿐만 아니라 유체의 종류, 온도, 물 포화율, 접촉상태, 유도분극, 측정기기 및 사용전원의 주파수 등, 여러 요인에 의하여 영향을 받는다. 이 연구는 암석의 비저항을 정확하고 정밀하게 측정하기 위한 기초 연구의 일환으로서, 비저항 실측자료를 비교 분석하는 과정을 통하여 비저항 측정에 영향을 주는 다양한 요소들을 추적하고, 아울러 비저항 측정에 있어서 최적의 환경 조건을 찾고자 하였다. 특히 온도, 물 포화율, 시료와 전극의 접촉상태, 측정 주파수의 영향 등이 종합적으로 분석되었으며, 전도성 접착제와 절연 테이핑 방법 그리고 시계열 비저항자료의 이용이 비저항 측정의 정확도와 정밀도 향상에 크게 기여할 수 있음을 보였다.

  • PDF

방전플라즈마 소결된 Bi0.5Sb1.5Te3의 열/전기적 특성 (The Electric and Thermal Properties of Spark Plasma Sintered Bi0.5Sb1.5Te3)

  • 이길근;최영훈;하국현
    • 한국분말재료학회지
    • /
    • 제19권4호
    • /
    • pp.285-290
    • /
    • 2012
  • The present study was focused on the analysis of the electric and thermal properties of spark plasma sintered $Bi_{0.5}Sb_{1.5}Te_3$ thermoelectric material. The crystal structure, microstructure, electric and thermal properties of the sintered body were evaluated by measuring XRD, SEM, electric resistivity, Hall effect and thermal conductivity. The $Bi_{0.5}Sb_{1.5}Te_3$ sintered body showed anisotropic crystal structure. The c-axis of the $Bi_{0.5}Sb_{1.5}Te_3$ crystal aligned in a parallel direction with applied pressure during spark plasma sintering. The degree of the crystal alignment increased with increasing sintering temperature and sintering time. The electric resistivity and thermal conductivity of the $Bi_{0.5}Sb_{1.5}Te_3$ sintered body showed anisotropic characteristics result from crystal alignment.

홍성 단층대에서의 전기, 전자 탐사 연구 (Electric and Electromagnetic Surveys of the Hongseong Fault Zone)

  • 권병두;이희순;박계순;오석훈;이춘기
    • 한국지구과학회지
    • /
    • 제24권4호
    • /
    • pp.361-368
    • /
    • 2003
  • 1978년에 규모 5.0의 지진이 발생한 홍성지역에 발달한 단층대의 전기, 전자적 특성을 조사하였다. 전기, 전자 탐사는 최근 토목공사현장에서 단층대 및 파쇄대 등의 연약지반을 확인하기 위한 수단으로 널리 쓰이고 있으며 이들 탐사로부터 얻어지는 전기비저항 구조는 연약대의 공간적 분포를 효과적으로 파악할 수 있는 정보를 제공한다. 홍성지역에 위치한 단층대를 가로질러 쌍극자배열 전기비저항탐사와 MT (Magnetotelluric) 탐사를 실시하였으며 역산을 통해 단층대의 전기비저항의 분포를 추정하였다. MT 탐사는 주단층대를 가로지르는 2.9 km의 측선상의 18측점에서 실시하였으며, 자기쌍극자를 인공 송신원으로 사용하였다 전기탐사는 단층대를 측선의 중앙으로 하여 전극간격이 50 m인 쌍극자배열전기비저항 탐사를 실시하였다. 두 탐사 결과는 예상단층선을 따라 좌우지역의 전기비저항이 서로 다른 양상으로 발달하고 있음을 보여주고 있으며, 특히 예상단층선을 따라서는 뚜렷한 저비저항대가 깊게 발달해 있음을 보여주고 있다. 홍성지역의 단층대에서 낮은 전기비저항분포를 보이는 부분이 수직으로 잘 발달해 있다는 것은 최근에 두 차례의 지진이 발생한 것처럼 이 지역 단층이 활동 중인 단층이라는 사실과 일치하는 결과를 보여주는 것이다. 본 연구 성과는 앞으로 홍성단층 뿐만이 아니라 우리나라에서 발생하는 지진들에 대한 연구에 기초 자료를 제공할 것이라 기대된다.

Electrical Resistivity and Charge Density of Bismuth Telluride Doped with Erbium

  • Yeom, Tae-Ho
    • Journal of Magnetics
    • /
    • 제10권4호
    • /
    • pp.149-151
    • /
    • 2005
  • The electric properties of a single crystal bismuth telluride doped with a small concentration of Erbium, $Bi_{z-x}Er_xTe_3$ with x = 0.002, are investigated as a function of temperature. The resistivity was obtained by using the van der Pauw method. The measured electrical resistivity is 78 ${\mu}{\Omega}cm$ at 4.2 K. The charge density of $Bi_{z-x}Er_xTe_3$ is found to be $2{\times}10^{19}/cm^3$ at 4.2 K. It turns out that $Bi_{z-x}Er_xTe_3$ is a p-type semiconductor. It is discussed that the high mobility and less density support that $Bi_{z-x}Er_xTe_3$ is a potential sensor with high energy resolution. Comparison with an established material (i.e. Au:Er alloy) is also discussed.