• 제목/요약/키워드: electric power installation

검색결과 738건 처리시간 0.019초

리튬 배터리를 연계한 100kVA UPQC 개발 및 성능시험 (The Development and Experimental Evaluation of 100kVA Unified Power Quality Conditioner interconnected to the Li-Battery System)

  • 이학주;채우규;박중성;손진만;최은식
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.102-110
    • /
    • 2012
  • This paper propose the advanced topology of UPQC, its DC link is connected with Lithium battery, to compensate the momentary interruptions. The proposed system can be operated as UPS mode using the parallel inverter, which control the charge or discharge of battery, in case of the interruption. We dvelop 100kVA UPQC using the proposed topology to rise the power quality and the reliability of Microgrid. We verify its usefulness through voltage compensation test, UPS operation test and etc. using Microgrid test facility.

Simulation Study on Measuring Pulverized Coal Concentration in Power Plant Boiler

  • Chen, Lijun;Wang, Yang;Su, Cheng
    • Journal of Information Processing Systems
    • /
    • 제15권1호
    • /
    • pp.189-202
    • /
    • 2019
  • During thermal power coal-fired boiler operation, it is very important to detect the pulverized coal concentration in the air pipeline for the boiler combustion stability and economic security. Because the current measurement methods used by power plants are often involved with large measurement errors and unable to monitor the pulverized coal concentration in real-time, a new method is needed. In this paper, a new method based on microwave circular waveguide is presented. High Frequency Electromagnetic Simulation (HFSS) software was used to construct a simulation model for measuring pulverized coal concentration in power plant pipeline. Theoretical analysis and simulation experiments were done to find the effective microwave emission frequency, installation angle, the type of antenna probe, antenna installation distance and other important parameters. Finally, field experiment in Jilin Thermal Power Plant proved that with selected parameters, the measuring device accurately reflected the changes in the concentration of pulverized coal.

공항 수.배전설비 제어시스템 표준화 (The Control System Standardization for Airport Electric Power Receiving and Distribution Facility)

  • 송영주;최홍규
    • 조명전기설비학회논문지
    • /
    • 제20권4호
    • /
    • pp.123-130
    • /
    • 2006
  • 국내공항의 경우 전기설비의 중요도에 비해 이에 대한 설계기준이나 표준지침이 제대로 갖추어지지 않아 오늘날 공항의 건설, 공항시설의 확충, 증설시에 체계적이고 표준화된 수 배전설비를 갖추기 어려운 실정이다. 따라서, 본 논문에서는 국내공항을 Code화에 의한 4등급으로 분류하고 수 배전설비에 대한 정의 및 적용범위를 설정한 후 기존 공항의 수 배전설비에 대한 문제점을 분석하고 공항 수 배전설비 제어시스템 기준과 공항 등급별 3단계 방안을 제시하여 공항등급별 표준 단선 결선도를 작성한 다음 단선 결선도에 따른 공항 수 배전설비 시설기준을 제시한다.

활선 상태에서의 OPGW 가선 시 전기적인 현상 고찰 (Electrical Consideration in OPGW Live-Line Installation)

  • 백주흠;김정년;전승익;김병수;이인호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 전기설비
    • /
    • pp.127-129
    • /
    • 2005
  • OPGW(Optical Ground Wire) whose demand is increasing worldwide have composite function as optical communication and grounding for preventing transmission line from lightning. While continuous efforts have been made to increase the transmission capacity and speed, the working method to replace the existing ground wire with OPGW under live-line condition is coming to force newly as installation aspects. Particularly, this requirement became more serious in developing country that the electric power supply is not sufficient and power outage is impossible for supply and dead of electric power LS cable Ltd. has developed the new installation method in full live-line condition to solve the confronted problem and to meet the market demand. In this paper, Electric Problems in live-line installation is considered to predict dry-band arcing. This can be used by Makers to predict dry-band arcing in insulating ropes installed on earth wire of power transmission system.

  • PDF

Investigation and Analysis of Interruption Characteristics for Industrial Customers

  • Choi, Sang-Bong
    • 조명전기설비학회논문지
    • /
    • 제21권4호
    • /
    • pp.45-52
    • /
    • 2007
  • Electric power is an important element in any modern economy. The availability of a reliable power supply at a reasonable cost is important for the economic growth and development of a country. Electric power utilities throughout the world therefore strive to meet customer demands economically with high quality and reliability. As the power industry moves towards open competition, therefore, there has been a call for a methodology by which to evaluate power system reliability through the use of customer interruption characteristics. This paper presents the results of an investigation and analysis of interruption characteristics of an industrial customer in Korea. This study used a direct visit survey to determine the investigation and analysis of electric service quality and the characteristics of industrial customers in Korea. A customer survey conducted throughout Korea via personal interviews of 660 sample customers is presented here. Variation according to characteristics of interruption such as duration, time of day, frequency and day of interruption was also investigated

전기철도시스템에서 직격뇌에 대한 가공지선의 내뇌효과 (Shielding Effects of an Overhead Ground Wire in the Electric Railway Systems due to Direct Lightning Strokes)

  • 임성정;김재철;추동욱;정용철;창상훈
    • 조명전기설비학회논문지
    • /
    • 제15권3호
    • /
    • pp.91-96
    • /
    • 2001
  • 본 논문은 전기철도시스템 고압 배전선로에서 직격뇌에 의한 가공지선의 영향에 대해서 설명하였다. EMTP를 사용하여 가공지선과 보안기의 영향을 정량적으로 분석하였다. 또한 전차선로의 구조변경과 피격전류의 크기, 파미값의 변화에 대한 영향도 평가하였다. 분석결과 기존 시스템에 가공지선의 설치는 전기철도시스템 고압 배전선로에 유도되는 피격전압을 억제하는 효과가 있음을 입증하였다.

  • PDF

색온도 구현방법에 따른 LED램프의 소비전력 측정 및 분석 (Analysis on the Measured Electric Power Consumption of Dimmable LED Lamps for a Specific Illuminance and Color Temperature)

  • 장인현;홍성관;최안섭
    • 조명전기설비학회논문지
    • /
    • 제25권2호
    • /
    • pp.24-31
    • /
    • 2011
  • The purpose of this study is to find an efficient way using dimmable LED lamps to describe specific target illuminance and color temperature. This study used 14 dimmable LED lamps as same or different color temperature. The method of study is to measure of electric power consumption using different color temperature of dimmable LED lamps that were combination of two or three dimmable LED lamps by simultaneously dimming. Through this method, the electric power consumption was compared with all combinations of the illuminance and color temperature.

초고압 XLPE 전력케이블에 대한 설치후 교류내전압시험 현장적용 (Field Application of AC High Voltage Test after Installation for EHV XLPE Power Cables)

  • 김영;권병일;성정규;한창석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1768-1770
    • /
    • 2001
  • EHV power cables can take any damage during shipping, transportation, handling, storage and installation. As the damage influences a reliability of the power cable system in the short and long periods, field tests have been required, for installers, to confirm the reliability of an installed system and, for utilities, to make sure the compatibility of an installed system. Of field tests, a HV withstand test for the cable insulation has been performed to check the soundness of the insulation. For EHV XLPE power cables, the test has been done by applying a specified d.c voltage till lately. But as some problems with the d.c test is emphasized and the equipment for the a.c test is improved, the a.c test is considered positively as an after-installation test. This paper describes the recent trends of the a and its recent application in the field.

  • PDF

무선전력전송 시스템의 모니터링 시스템 구축에 관한 연구 (A Study on Installation of Monitoring System of Wireless Power Transmission System)

  • 송영상;한운기;정진수;임현성;조성구
    • 조명전기설비학회논문지
    • /
    • 제29권4호
    • /
    • pp.47-53
    • /
    • 2015
  • The electrical safety and efficiency is the most important thing of the electric vehicle charging system. The prior system is contact charging system that is contacted directly by human. So, it has riskiness such as electric shock in the case of poor insulation or contact problems. To solve these safety issues and the convenience problems, a wireless power transmission system has been developed and is currently in trial operation. However, because high frequency is used in wireless power transmission system instead of commercial frequency, we need to apply protection measures concerning electric shock and equipment protection. Also, it should be accompanied by measuring efficiency for the effective operation of the wireless power transmission system. Therefore, we structured monitoring system in trial operation area of wireless power transmission system and applied decision algorithm for protection of human and equipment and economic operation of it.