• Title/Summary/Keyword: electric impedance

Search Result 583, Processing Time 0.028 seconds

Stability Tests on Anion Exchange Membrane Water Electrolyzer under On-Off Cycling with Continuous Solution Feeding

  • Niaz, Atif Khan;Lim, Hyung-Tae
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.369-376
    • /
    • 2022
  • In this study, the stability of an anion exchange membrane water electrolyzer (AEMWE) cell was evaluated in an on-off cycling operation with respect to an applied electric bias, i.e., a current density of 500 mA cm-2, and an open circuit. The ohmic and polarization resistances of the system were monitored during operation (~800 h) using electrochemical impedance spectra. Specific consideration was given to the ohmic resistance of the cell, especially that of the membrane under on-off cycling conditions, by consistently feeding the cell with KOH solution. Owing to an excess feed solution, a momentary increase in the polarization resistance was observed immediately after the open-circuit. The excess feed solution was mostly recovered by subjecting the cell to the applied electric bias. Stability tests on the AEMWE cell under on-off cycling with continuous feeding even under an open circuit can guarantee long-term stability by avoiding an irreversible increase in ohmic and polarization resistances.

Interpretation of Finite HMD Source EM Data using Cagniard Impedance (Cagniard 임피던스를 이용한 수평 자기쌍극자 송신원 전자탐사 자료의 해석)

  • Kwon Hyoung-Seok;Song Yoonho;Seol Soon-Jee;Son Jeong-Sul;Suh Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.2
    • /
    • pp.108-117
    • /
    • 2002
  • We have introduced a new approach to obtain the conductivity information of subsurface using Cagniard impedance over two-dimensional (2-D) model in the presence of horizontal magnetic dipole source with the frequency range of $1\;kHz\~1\;MHz$. Firstly, we designed the method to calculate the apparent resistivity from the ratio between horizontal electric and magnetic fields, Cagniard impedance, considering the source effects when the plane wave assumption is failed in finite source EM problem, and applied it to several numerical models such as homogeneous half-space or layered-earth model. It successfully provided subsurface information even though it is still rough, while the one with plane wave assumption is hard to give useful information. Next, through analyzing Cagniard impedance and apparent resistivity considering source effect over 2-D models containing conductive- or resistive-block, we showed that the possibility of obtaining conductivities of background media and anomaly using this approach. In addition, the apparent resistivity considering source effect and phase pseudosections constructed from Cagniard impedance over the isolated conductive- and resistive block model well demonstrated outlines of anomalies and conductivity distribution even though there were some distortions came from sidelobes caused by 2-D body.

A new transmission-line model for multi-layered PZT ultrasonic transducer (다층 PZT 초음파 트랜스듀서에 대한 새로운 전송선로형 등가회로의 제안)

  • Kim, Moo-Joon;Ha, Kang-Lyeol;Kim, Sung-Boo;Lee, Jong-Kyu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.29-37
    • /
    • 1995
  • A resonant frequency of piezoelectric transducer depends remarkably on the electric impedance connected to the vibrator. In this paper, using this effect of frequency controllable two layered PZT ultrasonic transducer is designed and its acoustic characteristics are analyzed by a new transmission model equivalent circuit. The theoretical and the experimental results of the electric impedance effect on the resonant frequency variation were compared and both results showed a good consistency each other. The resonant frequency has been controlled continuously in the wide frequency range of 180kHz~580kHz and the effective attenuations were less than 7dB in the frequency range of 330kHz~470kHz.

  • PDF

Research to Achieve Uniform Plasma in Multi-ground Capacitive Coupled Plasma

  • Park, Gi-Jeong;Lee, Yun-Seong;Yu, Dae-Ho;Lee, Jin-Won;Lee, Jeong-Beom;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.247.1-247.1
    • /
    • 2014
  • The capacitive coupled plasma is used widely in the semiconductor industries. Especially, the uniformity of the industrial plasma is heavily related with defect ratio of devices. Therefore, the industries need the capacitive coupled plasma source which can generate the uniform plasma and control the plasma's uniformity. To achieving the uniformity of the large area plasma, we designed multi-powered electrodes. We controlled the uniformity by controlling the power of each electrode. After this work, we started to research another concept of the plasma device. We make the plasma chamber that has multi-ground electrodes imaginary (CST microwave studio) and simulate the electric field. The shape of the multi-ground electrodes is ring type, and it is same as the shape of the multi-power electrodes that we researched before. The diameter of the side electrode's edge is 300mm. We assumed that the plasma uniformity is related with the impedance of ground electrodes. Therefore we simulated the imaginary chamber in three cases. First, we connected L (inductor) and C (capacitor) at the center of multi-ground electrodes. Second, we changed electric conductivity of multi-ground electrode. Third, we changed the insulator's thickness between the center ground electrode and the side ground electrode. The driving frequency is 2, 13.56 and 100 MHz. We switched our multi-powered electrode system to multi-ground electrode system. After switching, we measured the plasma uniformity after installing a variable vacuum capacitor at the ground line. We investigate the effect of ground electrodes' impedance to plasma uniformity.

  • PDF

Sintering and Electrical Properties of Mn-doped ZnO-TeO2 Ceramics (Mn을 첨가한 ZnO-TeO2 세라믹스의 소결과 전기적 특성)

  • Hong, Youn-Woo;Shin, Hyo-Soon;Yeo, Dong-Hun;Kim, Jong-Hee;Kim, Jin-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.1
    • /
    • pp.22-28
    • /
    • 2009
  • We investigated the sintering and electric properties of ZnO-1.0 at% $TeO_2$ (ZT1) and 1.0 at% Mn-doped ZT1(ZT1M1) system. $TeO_2$ itself melts at $732^{\circ}C$ in air but forms the $ZnTeO_3$ or $Zn_2Te_3O_8$ phase with ZnO as increasing temperature and therefore retards the densification of ZnO to $1000^{\circ}C$. In ZT1M1 system, also, the densification of ZnO was retarded up to $1000^{\circ}C$ and then reached > 90% of theoretical density above $1100^{\circ}C$. It was found that a good varistor characteristics(nonlinear coefficient $a{\sim}60$) were developed in ZT1M1 system sintered at $1100^{\circ}C$ due to Mn which known as improving the nonlinearity of ZnO varistors. The results of C-V characteristics such as barrier height (${\Phi}_b$), donor density ($N_D$), depletion layer (W), and interface state density ($N_t$) in ZT1M1 ceramics were $1.8{\times}10^{17}cm^{-3}$, 1.6 V, 93 nm, and $1.7{\times}10^{12}cm^{-2}$, respectively. Also we measured the resistance and capacitance of grain boundaries with temperature using impedance and electric modulus spectroscopy. It will be discussed about the stability and homogeneity of grain boundaries using distribution parameter ($\alpha$) simulated with the Z(T)"-logf plots.

Power Stage Design for a Surface Wireless Power Transmission System using a Coupled Electric Field (전계결합을 이용한 면대면 무선 에너지 전송회로 개발)

  • Choi, Sung-Jin;Kim, Se-Yeong;Choi, Byung-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.2
    • /
    • pp.143-148
    • /
    • 2014
  • Conventional wireless power transfer methods based on coupled magnetic fields need a complex winding structure on the surface of the energy transfer and shows poor efficiency near metal objects due to the eddy current effect. In this study, to mitigate these problems, we investigate an electric field-coupled power transmission system, which is less prone to metal object problems and EMI. Because of the fundamental physical limit in the size of link capacitances, a half-bridge converter with an impedance matching transformer is proposed and the design procedure is derived to provide a soft-switching scheme. Hardware implementation shows that the proposed scheme with a pair of 10cm by 10cm copper plate can power a 1.4W USB FAN in a separation of 0.2mm by using insulating paper when driven by 227 kHz gate pulse.

Electrochemical Characteristics of Reforming Activated Carbon with Nitrogenous Functional Group for Electric Double Layer Capacitor (전기이중층 커패시터용 질소성 작용기를 이용한 개질 활성탄의 전기화학적 특성)

  • Yang, Jeong-Jin;Choi, Young-Joo;Kim, Han-Joo;Yuk, Young-Jae;Park, Soo-Gil
    • Journal of the Korean Electrochemical Society
    • /
    • v.16 no.2
    • /
    • pp.65-69
    • /
    • 2013
  • In order to improve capacitance of activated carbon for electric double layer capacitors, peptide bond was induced on the surface of the activated carbon by urea. Urea induced activated carbon has been stabilized through carbonization. Electrochemical characteristics was observed by cyclic voltammetry for specific capacitance, electrochemical impedance spectroscope for measuring resistance and charge-discharge for testing the cyclic ability. In the result, specific capacitance is increased about 22.9% than the activated carbon. And it shows excellent cycle performance and decreasing resistance with the introduction of nitrogen functional groups.

Electric power generation from sediment microbial fuel cells with graphite rod array anode

  • Wang, Zejie;Lim, Bongsu
    • Environmental Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.238-242
    • /
    • 2020
  • Sediment microbial fuel cells (SMFCs) illustrated great potential for powering environmental sensors and bioremediation of sediments. In the present study, array anodes for SMFCs were fabricated with graphite rods as anode material and stainless steel plate as electric current collector to make it inconvenient to in situ settle down and not feasible for large-scale application. The results demonstrated that maximum power of 89.4 ㎼ was obtained from three graphite rods, twice of 43.3 ㎼ for two graphite rods. Electrochemical impedance spectroscopy revealed that three graphite rods resulted in anodic resistance of 61.2 Ω, relative to 76.0 Ω of two graphite rods. It was probably caused by the parallel connection of the graphite rods, as well as more biomass which could reduce the charge transfer resistance of the biofilm anode. The presently designed array configuration possesses the advantages of easy to enlarge the surface area, decrease in anodic resistance because of the parallel connection of each graphite rod, and convenience to berry into sediment by gravity. Therefore, the as prepared array node would be an effective method to fabricate large-scale SMFC and make it easy to in situ applicate in natural sediments.

Current limiting characteristics of the resistive and inductive SFCL in the double line-to-ground fault (2선 지락사고에 대한 저항형과 유도형 한류기의 전류제한특성)

  • Choi, Hyo-sang;Hyun, Ok-Bae;Kim, Sang-Joon;Han, Byoung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1369-1372
    • /
    • 1999
  • We investigated the current limiting characteristics of resistive and inductive SFCLs with 100${\Omega}$ of Quench impedance for a double line-to-ground fault, in the 154 kV transmission system. The fault simulation at the phase angles $0^{\circ}$, $45^{\circ}$, and $90^{\circ}$ showed that the resistive SFCL limited the fault current less than 17 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppressed the current below 12 kA, but with 3$\sim$5 kA of DC component which decreased to zero in 6 cycles. We concluded that the inductive SFCL had higher performance in current limiting but the resistive SFCL was better from the view point of DC components.

  • PDF

Arc Detection and Interruption Algorithm Design for Fire Protection (화재 방지를 위한 아크전류 검출 제어기 설계)

  • Ban, Gi-Jong;Won, Young-Jin;Lim, Seung-Ha
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.3
    • /
    • pp.19-24
    • /
    • 2005
  • Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, arc current control algorithm is designed for the interruption of arc fault current which is occurred in the local electric network. This arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and high frequency. Conventional arc current controller does not have the arc current interrupt function. Hence, Controller of arc current is designed for the interruption of arc fault current which has the modified arc characteristics.