• 제목/요약/키워드: electric field strength

검색결과 467건 처리시간 0.027초

3차원 전계해석에 의한 3상일괄형 초고압 GIB의 절연설계 검증 (Verification of Insulation Design for Three Phase Enclosure Type EHV Class GIB by 3D Electric Field Analysis)

  • 정진교;박경엽;신영준;장기찬;송기동;송원표;권기영;이철현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.482-484
    • /
    • 1995
  • In designing three phase enclosure type EHV class gas insulated bus (GIB), it is essential to estimate the magnitude and the position where the maximum electric field strength occur. The improvement of insulation design can only be initiated after those informations have been obtained. In this paper, the calculated electric field strength for three phase GIB of HICO 362kV 63kA GIS is presented. The result shows that the designed insulator has enough margin compared with the design criteria.

  • PDF

원통형 확산기를 사용한 전자파 잔향실내의 전기장 분포특성 (The Characteristics of Electric Field Distributions in a Reverberation Chamber using Cylindrical Diffuser)

  • 이용;이중근
    • 대한전자공학회논문지TC
    • /
    • 제45권8호
    • /
    • pp.121-127
    • /
    • 2008
  • 본 논문은 원통형 확산기를 사용한 전자파 잔향실내의 전기장 분포에 관하여 다루었다. $1{\sim}3$ GHz 주파수 대역의 QRD(Quadratic Residue Diffuser)와 원통형 확산기(Cylindrical Diffuser)를 설계 후 각각의 전기장 분포 특성을 비교하였다. 전기장 분포 특성 및 전기장 균일도를 조사하기 위해 FDTD(Finite-Difference Time-Domain) 수치 해석 방법을 사용하였으며, 2 GHz에서 수치해석 결과 원통형 확산기를 사용하였을 경우 기존의 QRD를 사용한 경우에 비하여 표준편차와 공차는 각각 0.11 dB, 0.43 dB 개선되었고, 전기장 세기는 QRD의 36.6 dBmV/m보다 높은 43.2 dBmV/m로 나타났으며, 편파 특성면에서도 QRD보다 개선되었음을 확인 할 수 있었다. 따라서 원통형 확산기를 사용한 전자파 잔향실이 소형 전자기기의 전자파 장해 및 복사 내성 측정을 위한 대용시험 시설로 사용될 수 있음을 확인하였다.

고밀도 폴리에틸렌의 전계 세기의 영향에 관한 연구 동향 (A Research Trend on High Density Polyethylene Electrical Strength)

  • 윤희광;김찬호;허인호;이정수;황종선;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1982-1983
    • /
    • 2007
  • In this work, the $TiO_2$ pigment influence in HDPE dielectric strength was analyzed. Chemical and structural characterizations were made to identify changes during the processing and your influence in the electrical properties. Formulations containing 0, 0.5, 1, 2.5, 4 and 6 of titanium dioxide were processed by extrusion and injection molding with stabilization-antioxidants, ultraviolet stabilizers and plasticizers. The electrical strength tests were analyzed by the statistical distribution of Weibull, and the maximum likelihood method. The high concentrations present lower values to electrical strength. The ${\beta}$ parameter could be using to insulator particles dispersion. The TiO2 concentration variation shows that these incorporations implicate strength values increase has a maximum (5,35MV/cm). High pigment concentration induces a little falls in property values. Observing the ${\beta}$ parameter, minimum experiment electric field (Ebmin) and electric strength value, found that the best electric perform formulation was the formulation with 2.5% TiO2 weight.

  • PDF

345[kV] 송전철탑 주변에서 전장과 자장의 측정과 분석 (Measurement and Analysis of Electric and Magnetic Fields near 345[kV] Transmission Tower)

  • 이복희;이승칠;안창환;길형준;전덕규;길경석
    • 조명전기설비학회논문지
    • /
    • 제12권3호
    • /
    • pp.14-21
    • /
    • 1998
  • 본 논문에서는 평판형 전장센서와 멀티턴 루우프형 자장센서를 이용하여 2회선 345[kV] 송전선로에서 발생하 는 극저주파 영역(ELF)의 전장과 자장의 값을 측정하고, 이들의 크기를 3차원 그립으로 나타내었다. 또한, 자장 은 부하전류에 비례하므로 부하변동에 따른 자장의 값올 예측할 수 있도록 그 송전선로의 대표적인 일부하 전류 곡선을 나타내었다 선로 중심점으로부터 횡방향 거리에 대한 측정값을 FIELDS 프로그램에 의해 계산된 이론 값과 비교하였다. 전장의 세기는 송전 철탑 내부와 주변에서 낮게 나타났고, 자장의 경우 최대값이 나타난 지점 은 중부하 회선쪽으로 이동하였으나, 대체로 철탑의 중심부분에서 최대치가 나타나는 경향을 보였다. 송전철탑 주변에서 최대 전장과 자장의 값은 각각 3.5[kV/m]와 $20[{\mu}T]$ 를 초과하지 않았으며, 본 연구에서 측정된 전장과 자장의 값은 관련 여러 국제기관에서 제시한 제한.권고치를 만족시키고 있다.

  • PDF

수분 활성 실리카 겔 분산계의 전기유변학적 특성 (Electrorheological Properties of Water Activated Silica Gel Suspensions)

  • 안병길;최웅수;권오관;문탁진
    • Tribology and Lubricants
    • /
    • 제13권3호
    • /
    • pp.115-123
    • /
    • 1997
  • The electrorheological (ER) behavior of suspensions in silicone oil of silica gel powder (average particle size 49 $\mu$m) absorbed water was investigated at room temperature with electric fields up to 2.4 KV/mm. In this paper, for development of succcessful ER fluids used for wide temperature range later, we would like to know a fundamental understanding of water on ER effect. As a first step, the ER fluids involving water activated silica gel were measured not only the electrical characteristics such as dielectric constant, current density and electrical conductivity but also the rheological properties on the strength of electric field, the quantity of dispersed phase and absorbed water. From the experimental results that water absorbed to the particles directly affects to the surface charge density of electric double layer model proposed by Schwarz and makes dielectric constant and current density of ER fluids increase. The current density and dynamic yield stress $($\tau$_y)$ of water activated silica gel suspensions was in exponential proportion to the strength of electric field, the quantity of dispersed phase and absorbed water. And the optimum water quantity and weight concentration of silica gel for electrorheological effect were 4-5 wt% and 15 wt%, respectively.

비접촉식 전류 검출 장치에 관한 연구 (A Study on the Current Detector with Non Contact Type)

  • 김기준
    • 한국전기전자재료학회논문지
    • /
    • 제31권5호
    • /
    • pp.351-356
    • /
    • 2018
  • Commonly, a live-line alarm can be used to measure the electric field strength of a high-voltage system to calculate its current, but it is hard to detect the electric field of shielded cables or concealed structures, such as underground distribution cables. Current sensors can detect the magnetic field in a single core wire, but they cannot determine the magnetic field about a double-core wire because the currents flow in opposite directions. Therefore, it is very difficult to detect certain current problems, such as a fault current in an extension line comprised of a double line. In this paper, to ultimately develop a sensor that can detect the current regardless of line conditions, we used a simulation to determine the concentration of the magnetic field dependent on the distribution of the external magnetic field and the path of each line's core.

오일함유 폐수 처리를 위한 전기정밀여과 공정 특성 (Characteristics of Crossflow Electro-microfiltration Process for Treatment of Oily Waste Water)

  • 최왕규;이재원;이근우
    • 멤브레인
    • /
    • 제12권4호
    • /
    • pp.216-225
    • /
    • 2002
  • 원자력 분야를 포함하는 다양한 산업에서 발생하고 있는 오일 함유 폐액의 처리에 있어서 전기여과막 공정의 적용성을 평가할 목적으로 폴리프로필렌 정밀여과막을 사용한 모의 오일 에멀젼 폐액의 막 여과 실험을 수행하였다. 이때 투과 플럭스에 대한 전기장의 효과 및 투과 플럭스에 영향을 주는 주요 인자들로써 막간 차압, 교차흐름 유속 및 오일 에멀젼 농도의 영향을 고찰하였다. 전기장을 가해주는 전기정밀여과 공정은 기존의 전기장을 사용하지 않는 막 여과 공정에 비해서 막 오염 문제를 현저히 개선함으로써 투과 플럭스가 크게 향상되었으며 장기간의 조업시에도 상당한 투과 플럭스의 유지가 가능함을 보였다.

Electric current control of creation and annihilation of sub-100 nm magnetic bubbles examined by full-field transmission soft X-ray microscopy

  • Je, Soong-Geun;Jung, Min-Seung;Im, Mi-Young;Hong, Jung-Il
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1201-1204
    • /
    • 2018
  • The effect of electric current pulses on a sub-100 nm magnetic bubble state in a symmetric Pt/Co multilayer was directly observed using a full-field transmission soft X-ray microscope (MTXM). Field-induced evolution of the magnetic stripe domains into isolated bubbles with their sizes down to 100 nm was imaged under varying external magnetic fields. Electric current pulses were then applied to the created magnetic bubbles, and it was observed that the bubbles could be either created or annihilated by the current pulse depending on the strength of applied magnetic field. The results suggest that the Joule heating plays a critical role in the formation and/or elimination of the bubbles and skyrmions. Finally, the schematic phase diagram for the creation and annihilation of bubbles is presented, suggesting an optimized scheme with the combination of magnetic field and electric current necessary to utilize skyrmions in the practical devices.

전기장분산법을 이용한 나노와 마이크로 혼합된 콤포지트의 전기적 특성 (Electrical Properties for Micro-and-Nano- Mixture Composites using Electric Field Dispersion)

  • 김정호;조대령;박재준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.32-32
    • /
    • 2010
  • A epoxy/multilayered silicate nanocomposite was prepared by a new AC electric application method and micro silica particle was poured into the nanocomposite in order to prepare epoxy/micro-and-nano- mixed composites (EMNC). Electric insulation breakdown strength was measured in a sphere-sphere electrode system designed for the prevention of edge breakdown and the data were estimated by Weibull plot. As the exfoliated silicate nano-plates were homogeniously dispersed in the micro silica particles, the insulation property was higherd.

  • PDF

$SF_6$ 가스중의 불평등전계에 있어서 이온류장 모델 (Model of Ion Flow Field under Nonuniform Field in $SF_6$ Gas)

  • 이형호;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.601-604
    • /
    • 1993
  • The effect of an insulator inserted along the axis of a red-to-plane gap on an ion flow field in $SF_6$ gas is investigated experimentally in the pressure region where a proceeding corona discharge exists. Without the insulator, the calculated electric field on the plane electrode agrees fairly well with the measured one. With the insulator, the ion flow field characteirstics may be attributed to the change in the electric field distribution by the accumulated charge, the increase in the ratio of the dielectric strength in gas gap to that along the insulator surface with the gas pressure, and the thermal diffusion of ions near the insulator.

  • PDF