• 제목/요약/키워드: elbow rehabilitation robot

검색결과 14건 처리시간 0.025초

힘측정기반 팔꿈치 재활로봇 설계 및 힘제어 (Design of an Elbow Rehabilitation Robot based on Force Measurement and its Force Control)

  • 김한솔;김갑순
    • 제어로봇시스템학회논문지
    • /
    • 제21권5호
    • /
    • pp.413-420
    • /
    • 2015
  • This paper describes the design of an elbow rehabilitation robot based on force measurement that enables a severe stroke patient confined to their bed to receive elbow rehabilitation exercises. The developed elbow rehabilitation robot was providewitha two-axis force/torque sensor which can detect force Fz and torque Tz, thereby allowing it to measure therotational force (Tz) exerted on the elbow and the signal force Fz which can be used as a safety device. The robot was designed and manufactured for severe stroke patients confined to bed, and the robot program was manufactured to perform flexibility elbow rehabilitation exercises. Asa result of the characteristics test of the developed rehabilitation robot, the device was safely operated while the elbow rehabilitation exercises were performed. Therefore, it is thought that the developed rehabilitation robot can be used for severe stroke patients.

거울치료가 가능한 착용형 팔꿈치 재활로봇 (Wearable Elbow Rehabilitation Robot Capable of Mirror Therapy)

  • 양지훈;백진슬;문인혁
    • 재활복지공학회논문지
    • /
    • 제8권2호
    • /
    • pp.73-78
    • /
    • 2014
  • 이 논문은 팔꿈치 재활 훈련에 있어서 거울치료 기법을 적용한 착용형 재활로봇을 제안한다. 거울치료는 건측의 팔꿈치 동작을 측정하여, 환측의 팔꿈치 훈련을 하는 것이다. 이를 위해 환측의 재활을 위한 착용형 장치 뿐만 아니라 건측 팔꿈치 동작을 측정하기 위한 착용형 센서도 개발하였다. 착용형 장치는 인체의 팔꿈치 구조를 고려하여 설계하였다. 착용형 센서는 굽힘센서와 광파이버를 이용한 센서를 각각 개발하여 센터의 특성을 평가하였다. 개발된 거울치료형 팔꿈치 재활로봇은 피험자의 동작에 따른 동작특성을 3차원 모션 측정장치로 평가하였다. 실험의 결과는 이 연구에서 개발된 착용형 팔꿈치 재활로봇이 적용 가능함을 보였다.

  • PDF

팔꿈치 경직 환자의 회복 운동을 위한 재활 로봇 시스템 개발 (Development of Rehabilitation Robot System for Patients with Elbow Spasticity)

  • 이정완;이재경
    • 산업기술연구
    • /
    • 제28권A호
    • /
    • pp.75-80
    • /
    • 2008
  • This paper describes the mechanical and control design of a robotic device for providing therapeutic assistance to arm movement following stroke. This is a new robot for arm therapy applicable to the training of activities of daily living in homes and clinics. This instrument has one degrees of freedom, and is equipped with position and force sensors. Repetitive movement can improve movement performance in patients with neurological or orthopaedic lesions. The application of robotics can serve to assist, enhance, evaluate, and document neurological and orthopaedic rehabilitation of movements. The new robot, the mechanical structure, the control circuit, the sensors and actuators and some safety aspects.

  • PDF

A Feasibility Study on a Robotic Exercise System for MDOF Physical Rehabilitation Therapy

  • Sim, Hyung Joon;Won, Joo Yeon;Han, Chang Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제18권11호
    • /
    • pp.1949-1960
    • /
    • 2004
  • This paper presents a robot system developed for medical purpose. A 6-degree-of-freedom robot was introduced for physical exercise and rehabilitation. This system was proposed for stroke patients or patients who cannot use one of their arms or legs. The robot system exercises the hemiplegic part based on the motion of normal part of a patient. Kinematic studies on the human body and robot were applied to develop the robotic rehabilitation exercise system. A clamp which acts as an end effector of the robot to hold a patient was designed and applied to the robot to guarantee the safety of patients. The proposed robotic rehabilitation system was verified by simulations and experiments on arm (elbow and shoulder) motion. Patients are expected to be able to exercise various motions by themselves with the proposed robotic rehabilitation system.

상지 재활을 위한 3-D 로봇 시스템의 개발 (Development of a 3-D Rehabilitation Robot System for Upper Extremities)

  • 신규현;이수한
    • 한국정밀공학회지
    • /
    • 제26권4호
    • /
    • pp.64-71
    • /
    • 2009
  • A 3-D rehabilitation robot system is developed in this paper. The robot system is for the rehabilitation of upper extremities, especially the shoulder and elbow joints, and has 3-D workspace for enabling occupational therapy to recover physical functions in activities of daily living(ADL). The rehabilitation robot system, which is driven by actuators, has 1 DOF in horizontal rotational motion and 2 DOF in vertical rotational motion, where all actuators are set on the ground. Parallelogram linkage mechanisms lower the equivalent inertia of the control elements as well as control forces. Also the mechanisms have high mechanical rigidity for the end effector and the handle. Passive motion mode experiments have been performed to evaluate the proposed robot system. The results of the experiments show and excellent performance in simulating spasticity of patients.

상지 재활을 위한 3-D 로봇 시스템의 혼합 위치/힘 제어 (Hybrid Position/Force Control of a 3-D Rehabilitation Robot System for Upper Extremities)

  • 이수한;신규현
    • 한국정밀공학회지
    • /
    • 제28권5호
    • /
    • pp.599-605
    • /
    • 2011
  • A 3-D rehabilitation robot system is developed. The robot system is for the rehabilitation of upper extremities, especially the shoulder and elbow joints, and has 3-D workspace for occupational therapy to recover physical functions in activities of daily living(ADL). The rehabilitation robot system has 1 DOF in horizontal rotational motion and 2 DOF in vertical rotational motion, where all actuators are set on the ground. Parallelogram linkage mechanisms lower the equivalent inertia of the control elements as well as control forces. Also the mechanisms have high mechanical rigidity for the end effector and the handle. In this paper, a hybrid position/force controller is used for controlling positions and forces simultaneously The controller is tuned according to the robot posture. The active motion modes for rehabilitation program consist of active-resisted motion mode and active-free motion mode. The results of the experiments show that the proposed motion modes provide the intended forces effectively.

로봇을 이용한 상지 재활 시스템에 관한 연구 (A Development of Rehabilitation System for Upper Limb Using Robot Manipulator)

  • 원주연;심형준;한창수
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권4호
    • /
    • pp.309-318
    • /
    • 2003
  • 본 연구는 현재 산업용으로 널리 사용되고 있는 수직 다관절 6자유도 로봇을 의료용 목적으로 적용하기 위해 수행하였다. 이미 산업용으로 제안되어 검증된 로봇을 사용한다면 비용, 시간적인 면에서 상당한 잇점이 있다. 따라서 본 논문에서는 산업용으로 제안된 로봇을 의료 목적으로 사용하여 연구하였다. 본 시스템은 뇌졸중 환자와 같이 한쪽 팔을 다친 사람들을 위해 제안하였다. 한쪽 팔이 비정상이고 다른 팔이 정상인 환자를 대상으로 정상인 팔의 움직임을 획득하여 마비되거나 정상으로 움직이기 어려운 팔을 운동시키도록 마스터-슬레이브 시스템을 구성하였다. 또한 팔꿈치와 어깨의 기구학을 해석하기 위하여 기존의 인체에 관한 연구 결과를 적용하였다. 또한 슬레이브 로봇에 힘 센서를 부착하여 환자의 재활 정도를 측정할 수 있도록 하였으며, 위험 상황에 대비함으로써 슬레이브 로봇의 안전성을 높였다. 이러한 시스템으로 인해 물리치료사의 도움 없이 환자 혼자 운동이 가능하도록 시스템을 구성하였다. 제안된 시스템과 제어 알고리즘은 실험과 시뮬레이션을 통하여 타당성을 검증하였다.

환자와 로봇의 모델 불확도를 고려한 상지재활로봇의 채터링 없는 슬라이딩 모드 제어 (Chattering Free Sliding Mode Control of Upper-limb Rehabilitation Robot with Handling Subject and Model Uncertainties)

  • 압둘 마난 칸;윤덕원;한창수
    • 제어로봇시스템학회논문지
    • /
    • 제21권5호
    • /
    • pp.421-426
    • /
    • 2015
  • Need to develop human body's posture supervised robots, gave the push to researchers to think over dexterous design of exoskeleton robots. It requires to develop quantitative techniques to assess human motor function and generate the command to assist in compliance with complex human motion. Upper limb rehabilitation robots, are one of those robots. These robots are used for the rehabilitation of patients having movement disorder due to spinal or brain injuries. One aspect that must be fulfilled by these robots, is to cope with uncertainties due to different patients, without significantly degrading the performance. In this paper, we propose chattering free sliding mode control technique for this purpose. This control technique is not only able to handle matched uncertainties due to different patients but also for unmatched as well. Using this technique, patients feel active assistance as they deviate from the desired trajectory. Proposed methodology is implemented on seven degrees of freedom (DOF) upper limb rehabilitation robot. In this robot, shoulder and elbow joints are powered by electric motors while rest of the joints are kept passive. Due to these active joints, robot is able to move in sagittal plane only while abduction and adduction motion in shoulder joint is kept passive. Exoskeleton performance is evaluated experimentally by a neurologically intact subjects while varying the mass properties. Results show effectiveness of proposed control methodology for the given scenario even having 20 % uncertain parameters in system modeling.

지능적 족형 보행 재활 보조 로봇의 개발 (Development of an Intelligent Legged Walking Rehabilitation Robot)

  • 김현;김정엽
    • 대한기계학회논문집A
    • /
    • 제41권9호
    • /
    • pp.825-837
    • /
    • 2017
  • 본 논문에서는 하지 보행 장애를 가진 환자가 사용하는 크러치에 로봇 기술이 적용된 새로운 타입의 착용식 족형 보행 재활 로봇에 대해 서술하였다. 개발된 로봇의 주된 특징은 크게 세 가지로 나뉜다. 첫 번째, 착용 방식의 특징으로서, 팔꿈치에 착용하여 환자를 보조하는 엘보 크러치와 달리 환자의 가슴부에 족형 로봇을 착용함으로써 보행 시 넓은 가슴 면적으로부터 하중을 분산시키고 팔에 작용하는 집중 하중을 제거하였으며, 팔과 손의 움직임을 자유롭게 하였다. 두 번째, 사용자의 보행 의지를 파악하는 방법으로서, 족형 로봇의 발에 부착된 3축 힘센서를 이용하여 지면 반발력의 크기와 방향으로부터 사용자의 보행의도를 추정하는 알고리즘을 제안하였고 이에 따라 가슴 착용형 로봇을 보행시켰다. 마지막으로, 계단 보행을 위한 근력 강화 방법으로서, 둔턱을 오르내리는 근력 훈련이 가능하도록 바닥 높낮이에 따라 상하 운동 궤적이 변화할 수 있는 둔턱 보행 기능을 구현하였다. 최종적으로 개발된 로봇이 보행 의도를 인지하고 로봇 다리로부터 보행 보조를 효과적으로 수행할 수 있다는 것을 실험을 통하여 확인하였고, 하지 근전도 측정을 통하여 보행 시 로봇이 하지 근력을 보조하는 성능을 정량적으로 검증하였다.