• Title/Summary/Keyword: elastography

Search Result 87, Processing Time 0.024 seconds

Early Prediction of Liver Fibrosis Using Shear Wave Elastography (전단파 탄성 초음파(Shear Wave Elastography)를 이용한 조기 간섬유화 예측)

  • Seo-Won Choo;Jong-Nam Song;Cheol-Min Jeon;Jae-Bok Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1057-1065
    • /
    • 2023
  • Non-invasive liver fibrosis diagnosis is crucial for patients with chronic liver diseases. Many patients cannot undergo liver tissue biopsy, so predicting the degree of liver fibrosis early through meaningful methods can reduce complications related to chronic liver diseases, such as liver cell carcinoma and cirrhosis. This study compared and analyzed the quantitative measurement of liver fibrosis using shear wave elastography in conjunction with liver ultrasound findings and their associations with serum biomarkers (p<0.05). The results showed that the shear wave elastography measurement in the normal group was 4.55 ± 0.69 kPa, while the abnormal contrast group with echogenic patterns had a measurement of 8.27 ± 1.83 kPa. The hepatitis B carrier group exhibited higher shear wave elastography measurements, and among serum biomarkers, AST, ALT, GGT, and PT showed statistically significant positive correlations with fibrosis severity according to SWE categories (p<0.05), while ALP and TB did not demonstrate statistically significant differences (p=0.163, p=0.567). Conversely, Albumin and PLT showed significant negative correlations (p<0.05). Clinically, utilizing shear wave elastography measurements through liver ultrasound in the tracking and repeat testing of liver fibrosis in chronic hepatitis B patients without cirrhosis can assist in achieving more objective diagnoses among healthcare providers.

Strain elastography of palatal tumors in conjunction with intraoral ultrasonography, computed tomography, and magnetic resonance imaging: 2 case reports

  • Ogura, Ichiro;Toshima, Hiroo;Akashiba, Tohru;Ono, Junya;Okada, Yasuo
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.73-79
    • /
    • 2020
  • Computed tomography (CT) and magnetic resonance imaging (MRI) can be useful for the evaluation of palatal lesions, and strain elastography (performed together with intraoral ultrasonography) is a relatively new sonographic imaging modality. This report describes 2 clinical cases in which strain elastography was used to assess palatal tumors in conjunction with intraoral ultrasonography, CT, and MRI. In the first case, diagnosed as a myoepithelioma, the strain was determined to be 0.000% (strain of normal tissue, 0.556%). In the second case, diagnosed as an adenoid cystic carcinoma, the determined strain was 0.000% (strain of normal tissue, 1.077%). Therefore, we conclude that intraoral strain elastography can be useful for evaluating palatal lesions.

Usefulness of Color-overlay Pattern of Thyroid Elastic Ultrasonography (갑상선 탄성 초음파 검사 시 칼라 오버레이 패턴의 유용성)

  • Park, Ji-Yeon;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.341-346
    • /
    • 2022
  • The color overlay pattern of thyroid shear wave elastography applied in this study distinguishes benign and malignant nodules based on the optimal cut-off value of 74.2 kPa. From august 2021 to september 2021, thyroid ultrasound and elastography were performed on 57 patients with thyroid lesions using an ultrasound device RS85 prestige (Samsung Medison, Korea) and a 2-14 MHz linear transducer. In addition, the results of classification by K-TIRADS for each thyroid nodule and the results of classification by color overlay pattern according to the kPa value of acoustic ultrasound were compared and analyzed. In the color overlay pattern, the results classified as 40 people from dark blue to light blue and 17 people from green to red were similar to the K-TIRADS category results, which were classified as 42 benign and 15 malignant. Between blue and light blue, benign, and between green and red, malignant. If the shear wave elastography method is applied before the fine-needle aspiration cytology of the thyroid nodule is performed, the differential diagnosis of thyroid tissue from benign and malignant can be predicted in advance, and it will help to reduce unnecessary invasive tests.

Usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases

  • Ogura, Ichiro;Nakahara, Ken;Sasaki, Yoshihiko;Sue, Mikiko;Oda, Takaaki
    • Imaging Science in Dentistry
    • /
    • v.48 no.3
    • /
    • pp.161-165
    • /
    • 2018
  • Purpose: To evaluate the usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases. Materials and Methods: Ten patients with oral and maxillofacial diseases and 28 volunteers drawn from our student doctors were examined by shear wave elastography with a 14-MHz linear transducer using an Aplio 300 apparatus (Canon Medical Systems, Otawara, Japan). A statistical analysis of the shear elastic modulus(kPa) of healthy tissue (the sublingual gland, submandibular gland, anterior belly of the digastric muscle, and geniohyoid muscle) in the 28 volunteers was performed using 1-way repeated measures analysis of variance with the Tukey honest significant difference test. The maximum shear elastic modulus(kPa) of 8 patients with squamous cell carcinoma (SCC) and 2 patients with benign lesions was evaluated with the Mann-Whitney U test. The analysis used a 5% significance level. Results: The mean shear elastic modulus of the sublingual gland ($9.4{\pm}3.7kPa$) was lower than that of the geniohyoid muscle ($19.2{\pm}9.2kPa$, P=.000) and the anterior belly of the digastric muscle ($15.3{\pm}6.1kPa$, P=.004). The maximum shear elastic modulus of the SCCs($109.6{\pm}14.4kPa$) was higher than that of the benign lesions($46.4{\pm}26.8kPa$, P=.044). Conclusion: Our results demonstrated the usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases. Shear wave elastography has the potential to be an effective technique for the objective and quantitative diagnosis of oral and maxillofacial diseases.

Value of Ultrasound Elastography in Assessment of Enlarged Cervical Lymph Nodes

  • Teng, Deng-Ke;Wang, Hui;Lin, Yuan-Qiang;Sui, Guo-Qing;Guo, Feng;Sun, Li-Na
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.2081-2085
    • /
    • 2012
  • Background: To investigate the value of ultrasound elastography (UE) in the differentiation between benign and malignant enlarged cervical lymph nodes (LNs). Methods: B-mode ultrasound, power Doppler imaging and UE were examined to determine LN characteristics. Two kinds of methods, 4 scores of elastographic classification and a strain ratio (SR) were used to evaluate the ultrasound elastograms. Results: The cutoff point of SR had high utility in differential diagnosis of benign and malignant of cervical lymph nodes, with good sensitivity, specificity and accuracy. Conclusion: UE is an important aid in differential diagnosis of benign and malignant cervical LNs.

Conventional Ultrasonography and Real Time Ultrasound Elastography in the Differential Diagnosis of Degenerating Cystic Thyroid Nodules Mimicking Malignancy and Papillary Thyroid Carcinomas

  • Wu, Hong-Xun;Zhang, Bing-Jie;Wang, Jun;Zhu, Bei-Lin;Zang, Ya-Ping;Cao, Yue-Long
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.2
    • /
    • pp.935-940
    • /
    • 2013
  • Background: To evaluate the diagnostic utility of conventional ultrasonography and real time ultrasound elastography in differentiating degenerating cystic thyroid nodules mimicking malignancy from papillary thyroid carcinoma. Methods: We retrospectively analyzed conventional ultrasonographic and elastographic characteristics of 19 degenerating cystic thyroid nodules mimicking malignancy in 19 patients, with 30 surgically confirmed PTCs as controls. Based on size, the nodules had been grouped into less than 10mm (group A) and greater than 10 mm (group B). We evaluated conventional parameters and elasticity pattern. Color-scaled elastograms were graded as to stiffness of nodules using an elasticity pattern from I (soft) to IV (stiff). Results: Degenerating cystic thyroid nodules were similar to PTCs in conventional ultrasonographic findings, but the former frequently showed oval to round in shape (group A, 69.2% vs 18.8%, P=0.017; group B, 66.7% vs 7.14%, P=0.017) and punctuate hyperechoic foci (group A, 61.5% vs 0, P<0.001; group B, 50% vs 0, P<0.001). On real time ultrasound elastography, 7 of 13 degenerating cystic thyroid nodules in group A were pattern I, 5 were pattern II, 1 was pattern III. One degenerating cystic thyroid nodule in group B was pattern II, 5 were pattern III. The area under the curve for elastography was 0.98 in group A (sensitivity 92.3%, specificity 100%, P = 0.002), and 0.88 in group B (sensitivity 16.7%, specificity 100%, P = 0.014). Conclusions: As a dependable imaging technique, elastography helps increase the performance in differential diagnosis of degenerating cystic thyroid nodule and malignancy.

Analysis of Liver Elasticity according to Ultrasound Findings (초음파 소견에 따른 간 탄성도 분석)

  • Chun, Hye-Ri;Jang, Hyon-Chol;Cho, Pyong-Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.883-889
    • /
    • 2021
  • This study was conducted on 101 patients who visited hospital for abdominal ultrasonography from May 2020 to December 2020. The purpose of this study was to find out the elasticity according to the ultrasound images (echo pattern, splenomegaly, hepatitis) during the ultrasound examination using the shear wave elastography. The shear wave elastography value of the normal group of the echo pattern was 5.75±1.58 kPa, and the group with the abnormal echo pattern was 8.84±4.94 kPa, and the shear wave elastography value of the abnormal group was high (p<0.05). In normal spleen size, hepatic elasticity value was 6.33±2.54 kPa, and hepatic elasticity value of splenomegaly was 13.73±5.48 kPa. In the case of splenomegaly, the liver elasticity value was high, and there was a statistically significant difference (p<0.05). As the spleen size increased, the liver elasticity value increased by 1.485 times, and as hepatitis progressed, the liver elasticity value increased by 1.573 times (p<0.05). As a result of analysis of concordance between ultrasound imaging findings and shear wave elastography, the Kappa value was found to be as high as 0.922 (p<0.05), which showed high concordance between the two test methods. Additional comparisons of liver elasticity values in shearwave elastography tests along with liver ultrasound findings are thought to be of great help in diagnosing liver fibrosis.

The study of utility about magnetic resonance elastography for measurements of liver stiffness : the comparisons of ADC value & T2 weighted image (간 경화도 측정을 위한 3.0T 자기공명 탄성계수 영상의 유용성에 대한 고찰 : 확산계수 영상 및 T2 강조 영상과의 비교)

  • Kim, Sang-Woo;Kang, Chung-Hwan;Kim, Sung-Ho;Kim, Kyung-Soo;Kim, Soon-Bae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.1
    • /
    • pp.21-29
    • /
    • 2012
  • The purpose of this study is to evaluate the mutual relations by measuring SNR from T2 weighted image and ADC values on the basis of the stiffness values from liver tissues. This study was conducted that total 37 people(23 of males and 11 of females) were taken the liver MRI examination and average age was $54.5{\pm}12.7$ years old. The equipment was MAGNETOM Skyra 3.0T (SIEMENS, Erlangen, Germany) and 32 channel body-array coil. The examination were conducted with HASTE T2 weighted image by axial plane, Spin-echo EPI (echo planner image) DWI (b-value = 800) and Magnetic resonance elastography. The ROIs (region of interest: 200-300 $mm^2$) were established on the basis of the first axial stiffness image corresponded 95% confidence interval from axial stiffness image and then were measured values. After drawing the grid lines, signals were measured SNR from T2 weighted image and ADC values on the same locations that were analysed other 3 planes respectively. The results were showed correlation (0.057) that were increased to SNR from T2 weighted image by increasing stiffness value that no significant difference statistically p = 0.003. Other results were showed correlations (-0.301) that were decreased to ADC values by increasing stiffness values that no significant difference statistically p = 0.088. In the 3.0T equipment, the results may be error in much the same fashion as the 1.5T from ADC values by evaluation of fibrosis stage. However, Magnetic resonance elastography would be useful method that is used to diagnose exactly liver fibrosis stages in the 3.0T.

  • PDF

Measurement of Viscoelastic Constants from Multiple Phase MR Elastography Fitting Elastic Wave (탄성파를 적용한 다중 위상 MR Elastography로부터의 점탄성 정수의 측정)

  • Jung, Nam-Chae
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.3
    • /
    • pp.119-129
    • /
    • 2012
  • In the medical field, the hardening of tissues is one of important informations used in diagnosis or understanding progress of disease, a quantitative measuring method of hardening is important for objective diagnosis. It has been proposed MRE(Magnetic Resonance Elastography) method that measures an index of hardening, viscoelastic properties in a noninvasive. Because the S/N ratio of MRE images go down when measuring viscoelastic properties from local wavelength and local damping factor of a propagating wave in MRE method, methods using multiple phase MRE images have been examined to decrease the effect of noise. We propose a method measuring viscoelastic properties after Fitting a function for multiple phase MRE images in this research. This proposed method has a advantage to set up arbitrarily the variation rate of a space direction of viscoelastic properties or the spatial resolution of measuring values according to changing of the noise included in images, though it applies viscoelastic wave for multiple phase MRE images. We confirmed the effectiveness of a proposed method by experiment using simulation images and experiment using silicone-gel phantom.

Preliminary Experiment for High-resolution Measurement of Tissue Mechanical Properties Using Dynamic Optical Coherence Elastography (동적 광단층 탄성영상법을 이용한 조직의 고해상도 기계적 성질 측정을 위한 예비 실험)

  • Kwon, Daa Young;Ahn, Yeh-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.3
    • /
    • pp.99-103
    • /
    • 2018
  • Optical coherence elastography (OCE) is based on optical coherence tomography (OCT), which is a noninvasive, high-resolution, cross-sectional imaging technique. In this paper, we have developed dynamic optical coherence elastography to measure elasticity, a mechanical property of tissue, by phase difference. A piezoelectric actuator was used for sinusoidal mechanical loading of samples. Before applying this method to biomaterial, we assessed the feasibility of OCE with samples of sponge, eraser, and sharp lead. Cross-sectional and phase-difference images of the sample were obtained under sinusoidal loading. The strain rate was calculated from the phase-difference information. To obtain the envelope of the phase-difference oscillations along the horizontal direction, Hilbert transformation was performed at each depth. The elevation of the envelope was represented by color mapping, and we could measure the relative elasticity within the sample by comparing the elevations. Finally, there was an advantage when we calculated the shear rate using self-interference in the sample arm, instead of the interference between sample and reference arms.