• 제목/요약/키워드: elastic local buckling

검색결과 94건 처리시간 0.02초

Seismic response estimation of steel buildings with deep columns and PMRF

  • Reyes-Salazar, Alfredo;Soto-Lopez, Manuel E.;Gaxiola-Camacho, Jose R.;Bojorquez, Eden;Lopez-Barraza, Arturo
    • Steel and Composite Structures
    • /
    • 제17권4호
    • /
    • pp.471-495
    • /
    • 2014
  • The responses of steel buildings with perimeter moment resisting frames (PMRF) with medium size columns (W14) are estimated and compared with those of buildings with deep columns (W27), which are selected according to two criteria: equivalent resistance and equivalent weight. It is shown that buildings with W27 columns have no problems of lateral torsional, local or shear buckling in panel zone. Whether the response is larger for W14 or W27 columns, depends on the level of deformation, the response parameter and the structural modeling under consideration. Modeling buildings as two-dimensional structures result in an overestimation of the response. For multiple response parameters, the W14 columns produce larger responses for elastic behavior. The axial load on columns may be significantly larger for the buildings with W14 columns. The interstory displacements are always larger for W14 columns, particularly for equivalent weight and plane models, implying that using deep columns helps to reduce interstory displacements. This is particularly important for tall buildings where the design is usually controlled by the drift limit state. The interstory shears in interior gravity frames (GF) are significantly reduced when deep columns are used. This helps to counteract the no conservative effect that results in design practice, when lateral seismic loads are not considered in GF of steel buildings with PMRF. Thus, the behavior of steel buildings with deep columns, in general, may be superior to that of buildings with medium columns, using less weight and representing, therefore, a lower cost.

동하중 등가 설계압을 받는 고속 경구조선 알루미늄 보강판부재의 구조응답 고찰 (Consideration of the Structural Response of High Speed Aluminum Planning Boat Stiffened Plate Member subjected to the Simplified Equivalent Dynamic Design Pressure)

  • 함주혁;강병윤;추경훈
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.408-413
    • /
    • 2004
  • High speed planning boats also have been required more and more the rational strength analysis and evaluation for the optimal structural design in respect of the structural lightness according to the high speed trend. Even though the suggestion of the simple type equation for the equivalent dynamic pressure is reasonable to design the scantling of ship structure conveniently, many research activities for more reasonable improvement of the simple design pressure, have been continued to suggest the more accurate equivalent static description of tire structural response such as the deflection and stress of hull structure. In this research, we focus on the aluminum bottom stiffened plate structure in which structural scantling is mainly depend on the local loads such as dynamic or impact pressure without other load effects and structural response for the simple dynamic equivalent pressure was investigated through the structural analysis. In order to investigate the structural response of the bottom stiffened plate structure subjected to the dynamic equivalent design pressure, linear and nonlinear structural analysis of the bottom stiffened plate structure of 4.3 ton aluminum planning boat was performed based on the equivalent static applied loads which were derived from the KR regulation and representative one among various dynamic equivalent pressure equations. From above analysis results, we found that the response such as deflection and stress of plate member was similar with the response results of one plate member model with fixed boundary, which was published previous paper and in case of KR design loading, all response of stiffened plate structure were within elastic limit. Through the nonlinear analysis, nearly elastic behavior including the slight geometrical nonlinear response was dominant but plastic local zone was appeared at $85\%$ limit load. Therefore, we can say that through tire linear and nonlinear analysis, this stiffened plate member has no structural strength problem based on the yield criteria in case within $60\%$ limit load except the other strength point of view such as the fatigue and buckling problem.

  • PDF

Experimental and numerical investigations on remaining strengths of damaged parabolic steel tubular arches

  • Huang, Yonghui;Liu, Airong;Pi, Yong-Lin;Bradford, Mark A.;Fu, Jiyang
    • Steel and Composite Structures
    • /
    • 제34권1호
    • /
    • pp.1-15
    • /
    • 2020
  • This paper presents experimental and numerical studies on effects of local damages on the in-plane elastic-plastic buckling and strength of a fixed parabolic steel tubular arch under a vertical load distributed uniformly over its span, which have not been reported in the literature hitherto. The in-plane structural behaviour and strength of ten specimens with different local damages are investigated experimentally. A finite element (FE) model for damaged steel tubular arches is established and is validated by the test results. The FE model is then used to conduct parametric studies on effects of the damage location, depth and length on the strength of steel arches. The experimental results and FE parametric studies show that effects of damages at the arch end on the strength of the arch are more significant than those of damages at other locations of the arch, and that effects of the damage depth on the strength of arches are most significant among those of the damage length. It is also found that the failure modes of a damaged steel tubular arch are much related to its initial geometric imperfections. The experimental results and extensive FE results show that when the effective cross-section considering local damages is used in calculating the modified slenderness of arches, the column bucking curve b in GB50017 or Eurocode3 can be used for assessing the remaining in-plane strength of locally damaged parabolic steel tubular arches under uniform compression. Furthermore, a useful interaction equation for assessing the remaining in-plane strength of damaged steel tubular arches that are subjected to the combined bending and axial compression is also proposed based on the validated FE models. It is shown that the proposed interaction equation can provide lower bound assessments for the remaining strength of damaged arches under in-plane general loading.

좌굴방지장치 영향을 고려한 복합재 적층판의 압축강도에 대한 이차원 크기 효과 (Two Dimensional Size Effect on the Compressive Strength of Composite Plates Considering Influence of an Anti-buckling Device)

  • 공창덕;이정환
    • Composites Research
    • /
    • 제15권4호
    • /
    • pp.23-31
    • /
    • 2002
  • 시편 게이지 면적($길이{\;}{\times}{\;}폭$)의 이차원 크기효과가 T300/924 $[45/-45/0/90]_3s$ 탄소섬유/에폭시 적층판의 압축거동에 대해 조사하였다. 개조된 압축시험치구(ICSTM)와 좌굴방지장치가 $30mm{\;}{\times}{\;}30mm,{\;}50mm{\;}{\times}{\;}50mm,{\;}70mm{\;}{\times}{\;}70mm,{\;}90mm{\;}{\times}{\;}90mm$의 게이지 길이와 폭을 가진 시편들의 압축시험에 사용하였다. 모든 경우의 파괴들은 시편 게이지 길이 내에서 주로 갑자기 발생하였다. 파괴 후 분석결과는 $0^{\circ}$층의 섬유의 미소좌굴에 의해 파괴를 시작하여 최종파괴를 일으키는 임계파괴기구일 것으로 생각되었다. 이것은 매트릭스 지배적인 파괴를 의미하며, 초기섬유굴곡에 따라 파괴가 지배적으로 시작된다는 것을 말한다 이것은 또한 제작공정과 품질이 압축강도를 결정하는 중요한 역할을 한다고 볼 수 있다. 좌굴방지장치를 장착하고 시험할 때 장치의 볼트 조임 토크에 따라 시편과의 접촉마찰 등에 의해 실제 압축강도 보다 크게 나타나는 결과를 보였다. 좌굴방지장치의 영향을 유한요소법을 이용하여 해석한 결과 실제 압축강도 보다 7% 정도 크게 나타남을 확인하였다. 부가적으로 홀을 갖는 시편들의 압축시험도 수행되었다. 홀에 의한 국부응력집중이 적층판 강도에 지배적 요인이었다. 파괴강도는 홀 크기와 시편 폭이 증가할수록 감소하였으나 탄성응력집중계수로 예측된 값보다는 일반적으로 크게 나타났다. 이것은 사용된 복합재가 이상적인 취성재질이 아니라는 것을 의미하며 홀 주위에서 다소간의 응력이완이 발생한다고 볼 수 있다. X선 검사 사진분석에서 섬유좌굴과 층간분리형태의 손상이 파괴하중의 약 80%에서 홀 가장자리로부터 시작되었고 임계파괴크랙길이인 2-3mm의 불안정한 상태에 도달하기 전까지는 하중 증가와 더불어 안정되게 파괴가 진전되었다(시편의 기하학적 크기에 의존함). 이 손상과 파괴는 선형 cohesive zone 모델로 해석되었다. 노치없는 시편의 압축강도와 평면 파괴인성의 측정된 적층판 변수들을 사용하여 홀의 크기와 시편 폭의 함수로서 홀을 갖는 적층판의 압축강도를 성공적으로 예측하였다.