• Title/Summary/Keyword: ejection fraction (EF)

Search Result 96, Processing Time 0.033 seconds

Global Left Ventricular Myocardial Work Efficiency in Patients With Severe Rheumatic Mitral Stenosis and Preserved Left Ventricular Ejection Fraction

  • Estu Rudiktyo;Amiliana M Soesanto;Maarten J Cramer;Emir Yonas;Arco J Teske;Bambang B Siswanto;Pieter A Doevendans
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.4
    • /
    • pp.191-199
    • /
    • 2023
  • BACKGROUND: Assessment of left ventricular (LV) function plays a pivotal role in the management of patients with valvular heart disease, including those caused by rheumatic heart disease. Noninvasive LV pressure-strain loop analysis is emerging as a new echocardiographic method to evaluate global LV systolic function, integrating longitudinal strain by speckle-tracking analysis and noninvasively measured blood pressure to estimate myocardial work. The aim of this study was to characterize global LV myocardial work efficiency in patients with severe rheumatic mitral stenosis (MS) with preserved ejection fraction (EF). METHODS: We retrospectively included adult patients with severe rheumatic MS with preserved EF (> 50%) and sinus rhythm. Healthy individuals without structural heart disease were included as a control group. Global LV myocardial work efficiency was estimated with a proprietary algorithm from speckle-tracking strain analyses, as well as noninvasive blood pressure measurements. RESULTS: A total of 45 individuals with isolated severe rheumatic MS with sinus rhythm and 45 healthy individuals were included. In healthy individuals without structural heart disease, the mean global LV myocardial work efficiency was 96% (standard deviation [SD], 2), Compared with healthy individuals, median global LV myocardial work efficiency was significantly worse in MS patients (89%; SD, 4; p < 0.001) although the LVEF was similar. CONCLUSIONS: Individuals with isolated severe rheumatic MS and preserved EF, had global LV myocardial work efficiencies lower than normal controls.

Quantitative Evaluation of the First Order Creatine-Kinase Reaction Rate Constant in in vivo Shunted Ovine Heart Treated with Oxandrolone Using Magnetization Transfer 31P Magnetic Resonance Spectroscopy (MT-31P-MRS) and 1 H/31P Double-Tuned Surface Coil: a Preliminary Study

  • Thapa, Bijaya;Dahl, Marjanna;Kholmovski, Eugene;Burch, Phillip;Frank, Deborah;Jeong, Eun-Kee
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.26-36
    • /
    • 2018
  • Purpose: Children born with single ventricle physiology demonstrate poor growth rate and suffer from malnutrition, which lead to increased morbidity and mortality in this population. We assume that an anabolic steroid, oxandrolone, will promote growth in these infants by improving myocardial energy utilization. The purpose of this paper is to study the efficacy of oxandrolone on myocardial energy consumption in these infants. Materials and Methods: We modeled single ventricle physiology in a lamb by prenatally shunting the aorta to the pulmonary artery and then postnatally, we monitored cardiac energy utilization by quantitatively measuring the first order reaction rate constant, $k_f$ of the creatine-kinase reaction in the heart using magnetization transfer $^{31}P$ magnetic resonance spectroscopy, home built $^1H/^{31}P$ transmit/receive double tuned coil, and transmit/receive switch. We also performed cine MRI to study the structure and dynamic function of the myocardium and the left ventricular chamber. The spectroscopy data were processed using home-developed python software, while cine data were analyzed using Argus software. Results: We quantitatively measured both the first order reaction rate constant and ejection fraction in the control, shunted, and the oxandrolone-treated lambs. Both $k_f$ and ejection fraction were found to be more significantly reduced in the shunted lambs compared to the control lambs, and they are increased in oxandrolone-treated lambs. Conclusion: Some improvement was observed in both the first order reaction rate constant and ejection fraction for the lamb treated with oxandrolone in our preliminary study.

Gallbadder Dynamics Before and After Extracorporeal Shock Wave Lithotripsy (체외충격파 담석 쇄석술 전후의 담낭운동성의 변화)

  • Lee, Myung-Hae;Suk, Jae-Dong;Moon, Dae-Hyuk;Kim, Myung-Hwan;Min, Young-Il
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.1
    • /
    • pp.53-60
    • /
    • 1991
  • Extracorporeal shock wave lithotripsy (ESWL) with adjunctive oral litholytic therapy has proven to be a useful treatment in selected patients with gallbladder stones. To study the effect of ESWL on gallbladder dynamics, $^{99m}Tc-DISIDA$ hepatobiliary scintigraphy was done for 25 patients with symptomatic gallstones and 10 normal controls. Of these 25 patients, 15 were treated with ESWL and adjunctive oral litholytic agents (ESWL group) and 10 were treated only with oral litholytic agents (UDCA group). After overnight fast and gallbladder visualization on a routine hepatobiliary scintigraphy with 7mCi of $^{99m}Tc-DISIDA$, subjects were given fatty meal and imaged with a gamma camera interfaced to a computer (1 frame/minute for 70 minutes). A gallbladder time-activity curve was generated and latent period (LP), ejection period (EP), ejection fraction (EF) and ejection rate (ER) were calculated. ESWL group were studied before, 1day after and 2weeks after ESWL, and WDCA group were studied before and 2weeks after starting oral medication. Mean basal EF was significantly reduced in patients but other parameters were not reduced. In ESWL group, mean EF and mean ER at lday after ESWL were reduced. In 3 of them, gallbladder was not visualized at all. Two weeks after ESWL, however, all parameters were recoverd to basal level. In UDCA group, all parameters were not changed significantly during medication. We can conclude that ESWL has such immediate adverse effect on gallbladder dynamics as reducing contractility and nonvisualization of gallbladder but it has no long-term effect.

  • PDF

Comparison of the Ejection Fraction Between Gated Blood Pool, Gated Blood Pool SPECT and Echocardiography (게이트심장혈액풀스캔과 게이트심장혈액풀 SPECT로 측정한 심박출계수의 심초음파와의 비교 연구)

  • Jeong, Ji-Uk;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Moo-Seok;Song, Hyeon-Seok;Park, Se-Yun;Kim, Jae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.150-154
    • /
    • 2010
  • Purpose: Ejection fraction (EF) is one of the most important factors that evaluate heart function. Recently, according to echocardiography and myocardial perfusion SPECT, the number of gated blood pool scan (planar GBP) is declining. Measurement of left ventricular ejection fraction using gated blood pool SPECT (GBPS) is known as relatively correspond with echocardiography. We compared EF derived from plnar GBP, GBPS and echocadiography using modified simpson method to determine the accuracy. Materials and Methods: From January 2007 to June 2010, planar GBP and GBPS were performed on 34 patients who admitted to Pusan National University Hospital (men 23, women 11, mean age $52.6{\pm}27.2$). Each patient was injected with $^{99m}{TcO_4}^-$ of 20 mCi after pyrophosphate injection and then scanned using both planar GBP and GBPS techniques. For image analysis, we use ADAC Laboratories, Ver. 4.20 software. The result analyzed was processed by SPSS 17.0 Win statistic program and statistical method applied in data analysis is one-way anova, Tukey's post hoc test, pearson correlation test. Results: One-way anova test show no significant difference (planar GBP $56.3{\pm}13.9%$; GBPS $60.4{\pm}16.0%$; echocardiography $59.1{\pm}14.4%$, p=0.486, p>0.05). Tukey's post hoc test show no significant difference (planar GBP-echocardiography p=0.697; GBPS-echocardiography p=0.928; planar GBP-GBPS p=0.469, p>0.05). Values for EF obtained with planar GBP and GBPS correlated well with those obtained with echocardiography (planar-echocardiography r=0.697; GBPS-echocardiography r=0.928; planar GBP-GBPS r=0.469). Conclusion: The problems of accuracy and reproducibility for planar GBP still remain. But planar GBP is a safe and non-invasive method. In addition, planar GBP is useful to evaluate patient with low resolution echocardiography images. GBPS is not appicated clinically. but GBPS can be obtain various left ventricular functional parameters. planar GBP, GBPS and echocardiography show a good correlation between each other. Therefore, planar GBP and GBPS are useful for evaluating left ventricular ejection fraction.

  • PDF

Effect of Korea Red Ginseng on the Symptoms and Hemodynamics in Healthy Elders

  • Jin En-Yuan;Li Ya-Jun;Yang Lian-Xing;Jin Ming;Wei Yu-Lin;Nam Ki Yeul
    • Proceedings of the Ginseng society Conference
    • /
    • 2002.10a
    • /
    • pp.27-34
    • /
    • 2002
  • Clinical study on hemodynamics of healthy elders before and after tread mill. Using doubleblind, placebo-controlled study design. Seventy-five 50-70 years old volunteers without organic disease were divided into two groups, Ginseng group and control group. Each subject was received 3 g Korea Red Ginseng (KRG) capsules or placebo per day for 4 weeks. Before and after administration 4 weeks, the symptoms were asked and hemodynamics parameter such as pump function, systolic function, preload and afterload were recorded before and after tread mill 1,5, 10 minutes by the method of thoracic impedance cardiograph. The result showed that Ginseng could improve quality of life, had obvious effect of increasing PEP (pre-ejection period), PEP/LVET (pre-ejection period/left ventricular ejection period), PCWP (wedged pressure pulmonary capillary). The change rate of HR (heart rate), SV (stroke volume) in KRG group were much lowered, while EF (ejection fraction), LVET (left ventricular ejection period), LVEDP (left ventricular end diastolic pressure) was recovered much quickly. The circulation showed Ginseng could improve the quality of life though its promoting circulation function which are increasing both the systolic function and the preload.

  • PDF

Modified Tei index in patients with Kawasaki disease by tissue doppler imaging (가와사키병 환아에서 Tissue doppler imaging으로 측정한 modified Tei 지수)

  • Kim, Hee Jung;Cha, Jung Hwa;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.11
    • /
    • pp.1202-1210
    • /
    • 2006
  • Purpose : A quantitative and easily measured Doppler index of combined systolic and diastolic ventricular myocardial performance (Tei index) was recently proposed as a potentially useful predictor of global myocardial performance. However, presence of heart rate fluctuation makes it unreliable. Therefore, the modified Tei index was introduced by using tissue Doppler imaging (TDI) which enables measuring contraction and relaxation velocities from myocardium simultaneously. The purpose of this study was to investigate the effectiveness of the modified Tei index in the evaluation of global cardiac function. Methods : Forty eight patients in the acute phase of Kawasaki disease (KD) were studied. These patients were divided into two groups according to the modified Tei index. TDI and conventional echocardiography were performed. Systolic velocity, systolic displacement, E' velocity, E' displacement, A' velocity and A' displacement were measured at the base, mid-septum and the apex of the interventricular septum. Ejection fraction (EF), Tei index and modified Tei index were estimated. Results : Modified Tei index correlated negatively with systolic displacement, E' displacement and A' displacement at the base. Modified Tei index correlated positively with ESR and CRP. EF and Tei index were normal in KD patients. Conclusion : Modified Tei index is a safe, feasible and sensitive index for evaluating global ventricular functions in spite of normal EF and Tei index in KD.

The Study on the Correlation of the Ejection Fraction of Multi Gated Blood Pool Scan and Echocardiography According to the Condition of Cardiac Function (심장기능상태의 분류에 따른 게이트심장혈액풀 검사와 심장초음파의 심박출계수 상관관계에 관한 고찰)

  • Lee, Dong Hun;Park, Jang Won;Nam, Ki Pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.57-61
    • /
    • 2015
  • Purpose We considered the correlation of Ejection Fraction (EF) which was analyzed by Multi Gated Blood Pool Scan (MUGA) and Echocardiography (ECHO) for the patients who were classified according to the condition of cardiac function. Materials and Methods We analyzed the patients (female 60) who were diagnosed with breast cancer and were examined by both MUGA and ECHO. The 30 patients (age: $58.27{\pm}13.48$) who were analyzed into less than 50% to 70% of EF were categorized as normal group and the other 30 patients (age: $53.70{\pm}8.45$) who were analyzed into less than 50% of EF were categorized as abnormal group. Statistical analysis with SPSS ver. 18 was applied. Results Each of the value of mean and standard deviation of normal group was $66.43{\pm}5.80$ (MUGA), $60.50{\pm}4.93$ (ECHO). There was a significant difference (p<0.001). Each of the value of mean and standard deviation of abnormal group was $41.93{\pm}7.58$ (MUGA), $41.70{\pm}11.49$ (ECHO). There was no significant difference (p>0.001). In the result, all 30 cases of normal group showed the same reading. 8 out of 30 cases in abnormal group showed inconsistency of the reading. Conclusion We could confirm the correlation of the EF in MUGA and ECHO statistically. There was difference between abnormal groups from the result of reading. If we are aware of the result according to the different cardiac function categorization, MUGA and ECHO can be used as even more accurate interchangeable test.

  • PDF

Differences in the Effects of Beta-Blockers Depending on Heart Rate at Discharge in Patients With Heart Failure With Preserved Ejection Fraction and Atrial Fibrillation

  • Young In Kim;Min-Soo Ahn;Byung-Su Yoo;Jang-Young Kim;Jung-Woo Son;Young Jun Park;Sung Hwa Kim;Dae Ryong Kang;Hae-Young Lee;Seok-Min Kang;Myeong-Chan Cho
    • International Journal of Heart Failure
    • /
    • v.6 no.3
    • /
    • pp.119-126
    • /
    • 2024
  • Background and Objectives: Beta-blockers (BBs) improve prognosis in heart failure (HF), which is mediated by lowering heart rate (HR). However, HR has no prognostic implication in atrial fibrillation (AF) and also BBs have not been shown to improve prognosis in heart failure with preserved ejection fraction (HFpEF) with AF. This study assessed the prognostic implication of BB in HFpEF with AF according to discharge HR. Methods: From the Korean Acute Heart Failure Registry, 687 patients with HFpEF and AF were selected. Study subjects were divided into 4 groups based on 75 beats per minute (bpm) of HR at discharge and whether or not they were treated with BB at discharge. Results: Of the 687 patients with HFpEF and AF, 128 (36.1%) were in low HR group and 121 (36.4%) were in high HR group among those treated with BB at discharge. In high HR group, HR at discharge was significantly faster in BB non-users (85.5±9.1 bpm vs. 89.2±12.5 bpm, p=0.005). In the Cox model, BB did not improve 60-day rehospitalization (hazard ratio, 0.93;95% confidence interval [95% CI], 0.35-2.47) or mortality (hazard ratio, 0.77; 95% CI, 0.22-2.74) in low HR group. However, in high HR group, BB treatment at discharge was associated with 82% reduced 60-day HF rehospitalization (hazard ratio, 0.18; 95% CI, 0.04-0.81), but not with mortality (hazard ratio, 0.77; 95% CI, 0.20-2.98). Conclusions: In HFpEF with AF, in patients with HR over 75 bpm at discharge, BB treatment at discharge was associated with a reduced 60-day rehospitalization rate.

The Comparison of Quantitative Indices by Changing an Angle of LAO View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 좌전사위상 각도의 변화에 따른 정량적 지표 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Ryu, Jae-Kwang;Kim, Seong-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.57-61
    • /
    • 2012
  • Purpose: The multi-gated cardiac blood pool scan is to evaluate the function of left ventricle (LV) and usefully observe a value of ejection fraction (EF) for a patient who is receiving chemotherapy. To calculate LVEF, we should adjust an angle of left anterior oblique (LAO) view to separate both ventricles. And by overlapped ventricles, it is possible to affect LVEF. The purpose of this study is to investigate and compare quantitative indices by changing an angle of LAO view. Materials and methods: We analyzed the 49 patients who were examined by multi-gated cardiac blood pool scan in department of nuclear medicine at Asan Medical Center from June to September 2011. Firstly, we acquired "Best septal" view. And then, we got images by addition and subtraction of angle for LAO view to anterior and lateral. We compared three LAO views for 20 people by 5 degrees and 39 people by 10 degrees. And we analyzed quantitative indices, EF, end diastole and end systole counts, by automated and manual region of interest (ROI) modes. Results: Firstly, we analyzed quantitative indices by automated ROI mode. In case of 5 degrees, the averages of EF are $61.0{\pm}7.5$, $62.1{\pm}7.1$, $60.9{\pm}6.7%$ ($p$=0.841) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $62.4{\pm}9.5$, $62.3{\pm}10.8$, $61.6{\pm}.9.3%$ ($p$=0.938) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Secondly, we analyzed quantitative indices by manual ROI mode. In case of 5 degrees, the averages of EF are $62.8{\pm}7.1$, $63.6{\pm}7.5$, $62.7{\pm}7.3%$ ($p$=0.903) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $65.5{\pm}9.0$, $66.3{\pm}8.7$, $63.5{\pm}.9.3%$ (p=0.473) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Conclusion: When an image is nearly "Best septal" view, the difference of LAO angle would not affect to change LVEF. Although there was no difference in quantitative analysis, deviations could happen when to interpret wall motion qualitatively by reading physicians.

  • PDF

Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Perfusion Single Photon Emission Tomography (심전도 게이트 심근관류 Tl-201 SPECT로 측정된 좌심실 기능 및 좌심실 용적의 정확성)

  • Pai, Moon-Sun;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.94-99
    • /
    • 2005
  • Electrocardiogram-gated single photon omission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are more blurred compared with Tc-99m tracers due to the increased amount of scattered photons and use of a smooth filter. The average myocardial count densities are approximately one-half those of conventional technetium tracers. However, Tl-201 is still widely used because of its well-established utility for assessing myocardial perfusion, viability and risk stratification. Gated SPECT with Tl-201 enables us to assess both post-stress and rest left ventricular volume and function. Previous studies with gated Tl-201 SPECT measurements of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) have shown high correlation with first-pass radionuclide angiography, gated blood pool scan, Tc-99m-MIBI gated SPECT, contrast ventriculography, echocardiography, and 3-dimensional magnetic resonance imaging. However, problems related to these studies include few agreement data of EDV and ESV, use of a reference method that is likely to have the same systemic errors (gated Tc-99m-MIBI SPECT), and other technical factors related to the count density of gated SPECT. With optimization of gated imaging protocols and more validation studies, gated Tl-201 SPECT would be an accurate method to provide perfusion and function information in patients with coronary artery disease.