• 제목/요약/키워드: ejected flame

검색결과 16건 처리시간 0.02초

둔각 물체를 이용한 엔진 나셀 화재 소화 특성 (The Characteristic of Extinguishment of Engine Nacelle Fire Using a Bluff Body)

  • 이정란;이의주
    • 한국안전학회지
    • /
    • 제27권1호
    • /
    • pp.20-25
    • /
    • 2012
  • The purpose of the study is to assess the extinguishing concentration of inert gases in engine nacelle fire. The experiment was performed with a two dimensional rectangular bluff body stabilized flames, where the fuel was ejected to counter flow and co-flow against an oxidizer stream. Two inert gases, $CO_2$ and $N_2$, were used for extinguishing agent in the oxidizer and methane was used for fuel. The main experimental parameters were the direction of injecting fuel, the kinds of agent and the velocity ratio between air and fuel streams, which controlled the mixing characteristic near bluff body and the strength of recirculation zone in the downstream. The result shows the flame structure and the mode were strongly dependent with fuel/air ratio and the fuel jet direction. For both flow configurations, the extinguishing concentration of $CO_2$ was smaller than the $N_2$ because of the large heat capacity of $CO_2$. However, the concentration of inert gasesat blowout was much smaller than those in the cup burner and coflow jet diffusion flames, which implies that the extinction mechanism of bluff body stabilized flames was mainly due to the aerodynamic aspect. Compared to co-flow fuel injection, the extinguishing concentration of inert gases under counter flow configuration was lower. The effect of direction might result from the mixing characteristic and strength of recirculation zonearound a bluff body. More details should be investigated for the characteristic of recirculation zone in the wake of bluff body using the LES(Large Eddy Simulation).

도시화재 시뮬레이션 구축을 위한 개구분출화재의 온도 예측 (Estimation of Flame Temperature Ejected from the Opening for the Development of Urban Fires Simulation.)

  • 김남혁;신이철;구인혁;남동군;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 춘계학술논문발표회 논문집
    • /
    • pp.346-350
    • /
    • 2010
  • 도시화재의 연소 확대성상을 모델화하기 위해 화재실의 개구를 통하여 분출하는 열기류의 온도 평가 실험을 실시하였다. 실험은 축소모형 형태로 개구 조건과 화원조건에 의해 진행이 되었다. 실험 결과 온도분포 Trajectory는 개구종횡비 n에 의해 횡정(橫井)의 연구결과와 비교하여 n=2일때를 제외하고는 다른 경향을 나타냈다. 동일 조건에서 분출화재보유열량 $Q_{ef}$은 개구 조건이 횡장창($B0.2m{\times}H0.1m$)이고, 단일개구일 때 가장 높은 값을 나타냈다. 또한, 분출화재의 발생 한계 발열속도 $Q_{verit}$에서도 굴웅아(堀雄児)의 연구와 유사한 결과를 보이며, 다른 개구조건보다 횡장창($B0.2m{\times}H0.1m$)일 때 높은 값을 나타냈다.

  • PDF

층류제트유동 불안정성에 미치는 교류 전기장 효과 (Effect of AC Electric Fields on Flow Instability in Laminar Jets)

  • 김경택;이원준;차민석;박정;정석호;권오붕;김민국;이상민
    • 한국연소학회지
    • /
    • 제21권3호
    • /
    • pp.1-6
    • /
    • 2016
  • The effect of applied electric fields on jet flow instability was investigated experimentally by varying the direct current (DC) voltage and the alternating current (AC) frequency and voltage applied to a jet nozzle. We aimed to elucidate the origin of the occurrence of twin-lifted jet flames in laminar jet flow configuration, which occur when AC electric fields are applied. The results indicate that a twin-lifted jet flames originates from cold jet instability, caused by interactions between negative ions in the jet flow via electron attachment as $O_2+e{\rightarrow}O_2{^-}$ when AC electric fields are applied. This was confirmed by experiments in which a variety of gaseous jets were ejected from a nozzle to which DC voltages and AC frequencies and voltages were applied, with ambient air between two deflection plates connected to a DC power source. Experiments in which jet flows of several gases were ejected from a nozzle and AC electric fields were applied in coflow-nitrogen provided further evidence. The flow instability occurred only for oxygen and air jets. Additionally, jet instability occurred when the applied frequency was less than 80 Hz, corresponding to the characteristic collision response time. The effect of AC electric fields on the overall structure of the jet flows is also reported. Based on these results, we propose a mechanism to reduce jet flow instability when AC electric fields are applied to the nozzle.

3성분계 인화성 혼합가스의 MESG에 관한 연구 (A Study on the MESG of Flammable Ternary Gas Mixtures)

  • 황경용;변정환;이규남;이택기
    • 한국가스학회지
    • /
    • 제20권3호
    • /
    • pp.30-37
    • /
    • 2016
  • 내압 방폭전기기계 기구는 인화성 가스가 존재하는 위험장소에서 사용되어도 인화성 가스의 점화원이 되지 않는 구조로 이루어져야 한다. 또한 전기 스파크를 발생시키는 부품이 점화원이 되어 기계 기구 내부에서 폭발 시 최대 압력에 견디고 내부 화염이 외부로 전파되어 가스나 증기 폭발을 일으키지 않도록 설계되어야 한다. 본 연구에서는 화염 틈새를 통해 외부로 분사되는 연소 생성물의 분사가 외부 가스나 증기를 점화시킬 정도의 온도나 에너지를 가질 수 없도록 하는 MESG(Maximum Experimental Safe Gap)의 중요한 물리적인 메커니즘에 대해 규명하였다. IEC 60079-20-1:2010 기준에 의해 프로판- 아세틸렌-공기로 이루어진 3성분계 혼합가스의 MESG를 실험하여 MESG 값을 측정하고 가스 폭발시의 최대 폭발압력을 측정하였다. 결과로는 아세틸렌 가스 보다는 폭발력이 낮은 프로판 가스의 조성이 MESG 값과 폭발압력에 더욱 큰 변수로 작용함을 알 수 있었다.

횡단류에 분사되는 액체 제트의 분무 및 연소 특성 (Spray and Combustion Characteristics of Liquid Jet in Cross Flow)

  • 이관형;김두만;구자예;황진석
    • 한국항공우주학회지
    • /
    • 제34권12호
    • /
    • pp.48-58
    • /
    • 2006
  • 횡단류에 분사되는 액체 제트의 분무 및 연소 특성에 대한 수치적 연구를 수행하였다. 수치 계산을 위해 3차원의 분무 및 화학반응 유동 해석에 유용한 KIVA 코드를 횡단류에서의 분무 해석에 적합하도록 수정하여 사용하였다. 액주의 분열과 리거먼트 및 액적의 분열 현상을 해석하기 위하여 wave 모델과 KH-RT hybrid 모델이 사용되었다. 침투길이는 유입공기의 속도가 감소하거나 분사속도가 증가함에 따라 증가하였다. 유입공기의 속도가 증가할수록 계산결과의 오차가 크게 발생함을 알 수 있었다. 연소 특성에 대한 수치 해석으로 연소실 내부의 화염전파 형상과 국부지역에서의 온도및 공해 배출량에 대한 결과를 얻었다.

최대실험안전틈새(MESG)와 폭발압력의 상관관계에 대한 연구 (A Study on the Correlation of MESG and Explosion Pressure)

  • 황경용;신운철;이택기
    • 한국가스학회지
    • /
    • 제20권1호
    • /
    • pp.29-39
    • /
    • 2016
  • 폭발성 가스가 존재하는 위험장소에서 사용하는 전기기기는 폭발성 가스의 점화원이 되지 않도록 설계되어야 한다. 내압방폭 구조의 설계는 전기 스파크를 발생시키는 부품을 가진 용기가 내부에서 가스나 증기의 폭발시 최대 압력에 견디고 내부 화염이 외부 가스나 증기 폭발로 전파되지 않도록 설계되어야 한다. 이 논문은 화염 틈새를 통해 외부로 분사되는 연소 생성물의 분사가 외부 가스나 증기를 점화시킬 정도의 온도나 에너지를 가질 수 없도록 하는 MESG(Maximum Experimental Safe Gap)의 중요한 물리적인 메커니즘에 대해 설명하였다. IEC 60079-20-1:2010 기준에 의해 프로판과 아세틸렌의 MESG를 실험하여 MESG 값을 측정하고 가스폭발시의 최대 폭발압력을 측정하였다. 결과로는 최소 MESG가 측정될 때 가스의 농도는 화학당량 농도보다 높고 폭발압력은 최소 MESG에서 가장 높게 나타났다.