• 제목/요약/키워드: efficiency of plating

검색결과 175건 처리시간 0.02초

Analysis of Ni/Cu Metallization to Investigate an Adhesive Front Contact for Crystalline-Silicon Solar Cells

  • Lee, Sang Hee;Rehman, Atteq ur;Shin, Eun Gu;Lee, Doo Won;Lee, Soo Hong
    • Journal of the Optical Society of Korea
    • /
    • 제19권3호
    • /
    • pp.217-221
    • /
    • 2015
  • Developing a metallization that has low cost and high efficiency is essential in solar-cell industries, to replace expensive silver-based metallization. Ni/Cu two-step metallization is one way to reduce the cost of solar cells, because the price of copper is about 100 times less than that of silver. Alkaline electroless plating was used for depositing nickel seed layers on the front electrode area. Prior to the nickel deposition process, 2% HF solution was used to remove native oxide, which disturbs uniform nickel plating. In the subsequent step, a nickel sintering process was carried out in $N_2$ gas atmosphere; however, copper was plated by light-induced plating (LIP). Plated nickel has different properties under different bath conditions because nickel electroless plating is a completely chemical process. In this paper, plating bath conditions such as pH and temperature were varied, and the metal layer's structure was analyzed to investigate the adhesion of Ni/Cu metallization. Average adhesion values in the range of 0.2-0.49 N/mm were achieved for samples with no nickel sintering process.

해양환경 중에서 Cr도금의 부식 특성에 관한 연구 (The Study on the Corrosion Characteristics of Cr Plating in Marine Environment)

  • 임우조;곽남인;윤병두
    • 수산해양기술연구
    • /
    • 제39권3호
    • /
    • pp.211-217
    • /
    • 2003
  • 해양환경의 비저항 변화에 따른 모재, Ni도금 및 Cr도금의 분극저항, 부식전류밀도, 부식억제율 및 분극지배기구에 관하여 연구한 결과 다음과 같은 결론을 얻었다. 1) Cr도금 및 Ni도금의 분극저항은 모재의 분극저항보다 더 높게 나타나고, 이들 재료의 분극저항은 비저항이 감소함에 따라 낮아진다. 2) 비저항이 낮아질수록 Cr도금 및 Ni도금의 부식전류밀도는 모재의 부식전류보다 더 억제됨에 따라 Ni 및 Cr도금의 부식억제율은 더 높게 된다. 3) 해양환경의 비정항에 따른 모재, Ni도금 및 Cr 도금의 부식반응은 음극지배로 판단된다.(이 논문의 결론부분임)

파형전류전해에 의한 Pb-Sn합금의 조성변화 및 균일전착력 (The Change of Composition and the Throwing Power of Pb-Sn Alloy Electrodeposits in Pulse Plating)

  • 예길촌;김용웅
    • 한국표면공학회지
    • /
    • 제22권4호
    • /
    • pp.197-206
    • /
    • 1989
  • The Composition and throwing power-of Pb-Sn alloy deposits are investigated in tems of the pulse parameters in pulse plating. Microhardness and intermal srress of alloy deposots are measured. The current efficiency of pulse plating is lower than that of D.C.plating while cathode overpotential and macro-throwing power noticebly increase with increasing peak current density. The Pb content of P.C. plated alloy deposits with increasing average current density, is relatively lower than of D.C. plated deposits at the same average current density. The internal stress of Pb-Sn alloy is not detected and the microhardness are 9.0kg/mm2 and 11kg/mm2 for D.C. plated P.C. plated deposits, respectively.

  • PDF

산업도금폐수 처리에 사용된 탄소폼 흡착소재의 중금속 탈착 및 회수에 관한 연구 (Study on Heavy Metal Desorption and Recovery of the Carbon Foam used in Industrial Plating Wastewater Treatment as Adsorbent)

  • 이다영;이창구;김대운;박상현;권지향;이상협
    • 대한환경공학회지
    • /
    • 제38권11호
    • /
    • pp.627-634
    • /
    • 2016
  • 본 연구에서는 탄소폼 흡착소재를 이용하여 산업도금폐수로부터 중금속을 흡착 제거한 후 탈착용액을 이용하여 제거된 중금속을 용출하고 회수하는 과정의 특성을 평가해 보고자 하였다. 용액의 조성에 따른 복합 중금속의 탈착 특성을 살펴본 결과 증류수 조건에서는 용출이 관측되지 않았으며, 탈착용액으로 HCl과 $H_2SO_4 $를 이용한 경우 높은 중금속 농도를 나타내었다. 탈착 용액을 이용함과 더불어 물리적 기술인 초음파 처리를 이용한 경우 중금속의 용출이 증진되는 것을 확인하였으며, 초음파 장치의 출력이 높고 반응 시간이 길수록 효율도 증가하는 것으로 나타났다. 탄소폼 흡착소재를 구리도금 세척수 처리에 적용시켜본 결과 200 반응기부피(Bed volume) 동안 안정적인 제거 성능을 나타내었으며, 흡착된 구리는 탈착용액을 이용하여 용출시킨 후 직류 전원 장치를 이용하여 회수할 수 있었다. 또한 구리가 회수된 탈착용액은 재이용 효율은 84.2%로 나타났다.

쌀보리 약배양을 위한 약치상 방법별 배양효율 (Anther Culture Efficiency According to Plating Method in Naked Barley)

  • 박태일;정선옥;김영진;김현순;서재환;박기훈;김정곤;윤성중
    • Journal of Plant Biotechnology
    • /
    • 제34권3호
    • /
    • pp.237-242
    • /
    • 2007
  • Barley anther culture is hard working to plating picking out anther from the glume and demand long time comparing to be short available development stage for effective culture. Also, it has been treatment massive materials due to low plantlet comparing to get desirable plants intensively. Consequently, this experiment was carried out trying to be more high barley anther culture effectively in terms of save plating effort. Plating materials and culture temperature affected anther culture efficiency are among the inoculation tissues or organs such as anthers, spikelets and whole panicles, culture efficiency was higher with spikelets in two-rowed than six-rowed barley due primarily to a lower contamination, and calli were induced within 30 to 50 days. Callus induction and plant regeneration rates were higher in cultures at $25^{\circ}C$ than at $15^{\circ}C$ and $20^{\circ}C$. Days to callus induction were 25 to 50 days at $25^{\circ}C$ and 50 to 60 days at $20^{\circ}C$.

고속 경질 크롬 도금 용액 개발에 관한 연구 (A study for development of high speed hard chrome plating solution)

  • 추현식;이홍로
    • 한국표면공학회지
    • /
    • 제25권5호
    • /
    • pp.263-269
    • /
    • 1992
  • To enhancing efficiency of hard chrome plating solution more highly, cathode current efficiency were surveyed connected with hardness of deposits, surface morphology, TEM analysis and corrosion test of anode materials. Efficiency war increased up to 26% values by adding catalyst and two kind of additives. With given bath composition and 6$0^{\circ}C$, 60A/d$\m^2$ electrolosis conditionss bright and micro cracked deposits were well obtained, which showed HV 1000 values. From corrosion tests, anode materials such as Pb-Te (0.02%) and Pb-Ag(1%) showed most anti-corrosive results. Through SEM micrograph observations, ef-fects of additives on levelling, brightness and micro crack properties of hard chrome deposits could be con-firmed. Also, through TEM analysis the fact that deposits from crack free solution or high speed solution were more fine than from sargent solution could be confirmed.

  • PDF

Influence of Nickel Electroplating on Hydrogen Chloride Removal of Activated Carbon Fibers

  • Park, Soo-Jin;Jin, Sung-Yeol;Ryu, Seung-Kon
    • Carbon letters
    • /
    • 제5권4호
    • /
    • pp.186-190
    • /
    • 2004
  • In this work, a nickel metal (Ni) electroplating on the activated carbon fiber (Ni/ACFs) surfaces was carried out to remove the toxic hydrogen chloride (HCl) gas. The surface properties of the treated ACFs were determined by using nitrogen adsorption isotherms at 77 K, SEM, and X-ray diffraction (XRD) measurements. HCl removal efficiency was confirmed by a gas-detecting tube technique. As a result, the nickel metal contents on the ACF surfaces were increased with increasing the plating time. And, it was found that the specific surface area or the micropore volume of the ACFs studied was slightly decreased as increasing the plating time. Whereas, it was revealed that the HCl removal efficiency containing nickel metal showed higher efficiency values than that of untreated ACFs. These results indicated that the presence of nickel metal on the ACF surfaces played an important role in improving the HCl removal over the Ni/ACFs, due to the catalytic reactions between nickel and chlorine.

  • PDF

Electrodialysis of metal plating wastewater with neutralization pretreatment: Separation efficiency and organic removal

  • Park, Yong-Min;Choi, Su-Young;Park, Ki-Young;Kweon, Jihyang
    • Membrane and Water Treatment
    • /
    • 제11권3호
    • /
    • pp.179-187
    • /
    • 2020
  • Electrodialysis has been applied for treatment of industrial wastewater including metal electroplating. The wastewater from metal plating industries contains high concentrations of inorganics such as copper, nickel, and sodium. The ions in the feed were separated due to the electrical forces in the electrodialysis. The concentrate compartment is exposed to the elevated concentrations of the ions and yielded inorganic precipitations on the cation exchange membranes. The presence of organic matter in the metal plating wastewater affects complex interfacial reactions, which determines characteristics of inorganic scale fouling. The wastewater from a metal plating industry in practice was collected and the inorganic and organic compositions of the wastewater were analyzed. The performance of electrodialysis of the raw wastewater was evaluated and the effects of adjusting pH of the raw water were also measured. The integrated processes with neutralization and electrodialysis showed great removal of heavy metals sufficient to discharge to aquatic ecosystem. The organic matter in the raw water was also reduced by the neutralization, which might enhance removal performance and alleviate organic fouling in the integrated system.

Ni/Cu 금속전극 태양전지의 Ni electroless plating에 관한 연구 (The Research of Ni Electroless Plating for Ni/Cu Front Metal Solar Cells)

  • 이재두;김민정;권혁용;이수홍
    • 한국전기전자재료학회논문지
    • /
    • 제24권4호
    • /
    • pp.328-332
    • /
    • 2011
  • The formation of front metal contact silicon solar cells is required for low cost, low contact resistance to silicon surface. One of the front metal contacts is Ni/Cu plating that it is available to simply and inexpensive production to apply mass production. Ni is shown to be a suitable barrier to Cu diffusion into the silicon. The process of Ni electroless plating on front silicon surface is performed using a chemical bath. Additives and buffer agents such as ammonium chloride is added to maintain the stability and pH control of the bath. Ni deposition rate is found to vary with temperature, time, utilization of bath. The experimental result shown that Ni layer by SEM (scanning electron microscopy) and EDX analysis. Finally, plated Ni/Cu contact solar cell result in an efficiency of 17.69% on $2{\times}2\;cm^2$, Cz wafer.

Pilot scale membrane separation of plating wastewater by nanofiltration and reverse osmosis

  • Jung, Jaehyun;Shin, Bora;Lee, Jae Woo;Park, Ki Young;Won, Seyeon;Cho, Jinwoo
    • Membrane and Water Treatment
    • /
    • 제10권3호
    • /
    • pp.239-244
    • /
    • 2019
  • Plating wastewater containing various heavy metals can be produced by several industries. Specifically, we focused on the removal of copper (Cu2+) and nickel (Ni+) ions from the plating wastewater because all these ions are strictly regulated when discharged into watershed in Korea. The application of both nanofiltration (NF) and reverse osmosis (RO) technologies for the treatment of wastewater containing copper and nickel ions to reduce fresh water consumption and environmental degradation was investigated. In this work, the removal of copper (Cu2+) and nickel (Ni+) ions from synthetic water was studied on pilot scale remove by before using two commercial nanofiltration (NF) and reverse osmosis(RO) spiral-wound membrane modules (NE2521-90 and RE2521-FEN by Toray Chemical). The influence of main operating parameters such as feed concentration on the heavy metals rejection and permeate flux of both membranes, was investigated. Synthetic plating wastewater samples containing copper ($Cu^{2+}$) and nickel ($Ni^{2+}$) ions at various concentrations(1, 20, 100, 400 mg/L) were prepared and subjected to treatment by NF and RO in the pilot plant. The results showed that NF, RO process, with 98% and 99% removal for copper and nickel, respectively, could achieve high removal efficiency of the heavy metals.