• Title/Summary/Keyword: efficiency factor

Search Result 3,813, Processing Time 0.028 seconds

An Empirical Study on the e-Service Quality of Public Administration Considered CRM (CRM을 고려한 공공행정 e-서비스 품질에 관한 실증적 연구)

  • Lee, Chae-Eon;Gim, Gwang-Yong
    • Journal of Information Technology Services
    • /
    • v.5 no.2
    • /
    • pp.1-23
    • /
    • 2006
  • An Empirical study was done for finding the e-service quality of public administration focused on customer relationship management(CRM). The e-service quality of public administration was categorized as system quality, information quality, service quality, and CRM after doing a literature review in e-service quality and public administration. The validity and reliability of a questionnaire were examined through factor analysis and regression analysis was done using the customer satisfaction and efficiency improvement of public administration as dependent variables and the 7 factor scores from the factor analysis as independent variables. The results show for that 6 factors are not only very important in explaining the customer satisfaction but also partially important for efficiency improvement of public administration. In particular, CRM has significant effect on both customer satisfaction and efficiency improvement of public administration.

Optimal Design of Low-Speed Secondary-Sheet Single-Sided Linear Induction Motor

  • Shiri, Abbas;Shoulaie, Abbas
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.581-587
    • /
    • 2013
  • Among different linear motors, single-sided linear induction motors have been widely used in industry due to their simplicity and low construction cost. However, these types of motors suffer from low efficiency and power factor. In this paper, an effective procedure is proposed to design single-sided linear induction motors. The designed motor is simulated in MATLAB software in order to investigate the effect of design parameters on the performance of the machine. Regarding the obtained results, the Genetic Algorithm is employed to optimize the design considering product of efficiency and power factor as objective function. The results show significant improvement of the performance. Finally, experimental results and 2D finite element method is used to validate the model parameters and the optimization results.

High Power Factor High Efficiency PFC AC/DC Converter for LCD Monitor Adapter (LCD 모니터의 어댑터를 위한 고역률 고효율 PFC AC/DC 컨버터)

  • Park K. H.;Kim C. E.;Youn M. J.;Moon G. W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.85-89
    • /
    • 2003
  • Many single-stage PFC(power-facto.-correction) ACHC converters suffer from the high link voltage at high input voltage and light load condition. In this paper, to suppress the link voltage, a novel high power factor high efficiency PFC AC/DC converter is proposed using the single controller which generates two gate signals so that one of them is used far gate signal of the flyback DC/DC converter switch and the other is applied to the Boost PFC stage. A 130w prototype for LCD monitor adapter with universal input $(90-265V_{rms})$ and 19.5V 6.7A output is implemented to verify the operational principles and performances. The experimental results show that the maximum link voltage stress is about 450V at 270Vac input voltage. Moreover, efficiency and power factor are over $84\%$ and 0.95, respectively, under the full load condition.

  • PDF

A Study on Isolated DCM Converter for High Efficiency and High Power Factor

  • Kwak, Dong-Kurl
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.477-483
    • /
    • 2010
  • This paper is studied on a novel buck-boost isolated converter for high efficiency and high power factor. The switching devices in the proposed converter are operated by soft switching technique using a new quasi-resonant circuit, and are driven with discontinuous conduction mode (DCM) according to pulse width modulation (PWM). The quasi-resonant circuit makes use of a step up-down inductor and a loss-less snubber capacitor. The proposed converter with DCM also simplifies the requirement of control circuit and reduces a number of control components. The input ac current waveform in the proposed converter becomes a quasi sinusoidal waveform in proportion to the magnitude of input ac voltage under constant switching frequency. As a result, it is obtained by the proposed converter that the switching power losses are low, the efficiency of the converter is high, and the input power factor is nearly unity. The validity of analytical results is confirmed by some simulation results on computer and experimental results.

A High Power Factor and High Efficiency Three Phase Boost Converter using auxiliary Partial Resonant circuit (보조 부분 공진 회로를 이용한 고역률 고효율 삼상 부스트 컨버터)

  • Suh, Ki-Young;Kwon, Soon-Kurl;Lee, Hyun-Woo;Kim, Young-Mun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.4
    • /
    • pp.212-218
    • /
    • 1999
  • A new partial resonant three phase boost converter with high power factor and high efficiency is proposed. The proposed boost converter is constructed by using a resonant network in parallel with the swithch of the conventional boost converter. The devices are switched at zero voltage or zero current eliminating the switching loss. A new auxiliary partial resonant boost converter achieves zero-voltage switching(ZVS) or zero-current switching(ZCS) for all switch devices without increasing their voltage and current stresses.

  • PDF

Technical Inefficiency Effects and Technological Change in Bangladesh Food Industry: A Stochastic Frontier Analysis

  • Rana, Md. Masud;Baten, Md. Azizul;Rabman, Mezbahur
    • Journal of the Korean Data and Information Science Society
    • /
    • v.19 no.4
    • /
    • pp.1449-1463
    • /
    • 2008
  • This paper considers three different models with two functional forms, Cobb-Douglas and Translog, for the stochastic frontier production function of food manufacturing industry of Bangladesh over the period 1981-1982 to 1999-2000. The models are proposed by Battese and Coelli (1992, 1995) and Huang and Liu (1994). The technical efficiency, total factor productivity, technological change and technical efficiency change have been estimated in the frontier models. The results indicate that 41.47%, 59.30% and 70.98% of the potential output are being realized in this sector. The mean increments in total factor productivity are approximately 2%, 9% and 4% respectively.

  • PDF

Design of New Induction Heating Power Supply for Forging Applications Using Current-Source PWM Converter and Inverter (전류원 PWM 컨버터 / 인버터를 이용한 새로운 단조용 유도가열 전원장치의 설계)

  • Choi, Seung-Soo;Lee, Chang-Woo;Kim, In-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1602-1610
    • /
    • 2018
  • Induction heating can convert electrical energy to thermal energy with high conversion efficiency and quick heating. Currently, a current source rectifier/inverter-fed parallel resonant circuit is widely used as an induction heating power supply for forging applications. However, the conventional induction heating power supplies composed of phase-controlled rectifier and SCR inverter have low efficiency and low power factor at input side, and require additional starting circuitry. So this paper proposes new induction heating power supply topologies for forging applications which have high power factor, high efficiency, and large output power. It also suggests detailed design guideline.

Electronic Ballast Using a Symmetrical Half-bridge Inverter Operating at Unity-Power-factor and High Efficiency

  • Suryawanshi Hiralal M.;Borghate Vijay B.;Ramteke Manojkumar R.;Thakre Krishna L.
    • Journal of Power Electronics
    • /
    • v.6 no.4
    • /
    • pp.330-339
    • /
    • 2006
  • This paper deals with novel electronic ballast based on single-stage power processing topology using a symmetrical half-bridge inverter and current injection circuit. The half-bridge inverter drives the output parallel resonant circuit and injects current through the power factor correction (PFC) circuit. Because of high frequency current injection and high frequency modulated voltage, the proposed circuit maintains the unity power factor (UPF) with low THD even under wide variation in ac input voltage. This circuit needs minimum and lower sized components to achieve the UPF and high efficiency. This leads to an increase in reliability of ballast at low cost. Furthermore, to reduce cost, the electronic ballast is designed for two series-connected fluorescent lamps (FL). The analysis and experimental results are presented for ($2{\times}36$ Watt) fluorescent lamps operating at 50 kHz switching frequency and input line voltage (230 V, 50 Hz).

Soft switching high power factor buck converter using loss less snubber circuit (무손실 스너버 회로를 이용한 소프트 스위칭 강압형 고역률 컨버터)

  • 구헌회;변영복;김성철;서기영;이현우
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.6
    • /
    • pp.77-84
    • /
    • 1997
  • buck type converter doesn't appear when an input voltag eis lower than an output voltage. This is the main reason the buck converter has not been used for high power factor converters. In this paper, soft switching high power factor buck converter is proposed. This converter is composed of diode rectifier, input capacitor can be small enough to filter input current, buck converter with loss less snubber circuit. Converter is operated in discontinous conduction mode, turn on of the switching device is a zero current switching (ZCS) and high powr factor input is obtianed. In addition, zero voltage switching (ZVS) at trun off is achieved and switching loss is reduced using loss less snubber circuit. The capacitor used in the snubber circuit raised output voltage. Therefore, proposed converter has higher output voltage and higher efficiency than conventional buck type converter at same duty factor in discontinous conduction mode operation. High power factro, efficiency, soft switching operation of proposed converter is veified by simulation using Pspice and experimental results.

  • PDF

Eco-Efficiency Assessment of the Recycling Process in Resources Recycling Center (자원재활용센터의 재활용 공정에 대한 생태효율성 평가)

  • KIM, Tae-Seok;KIM, Dong-Gyue;CHUNG, Yong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.6
    • /
    • pp.1812-1821
    • /
    • 2015
  • In this study, we evaluate the eco-efficiency for recycling processes of Busan Resources Recycling Center for each year from 2010-2012. It analyze the impact of global warming on the power consumption by Life Cycle Assessment. Also calculate the economic value by net profit components those are sales amount and electric charge in accordance with the process operation. On the basis of these results, each of the eco-efficiency Factor analysis and dynamics analysis of 2011 and 2012 as the base year to 2010 are performed. As a result, the impact of global warming in all the recycling processes is increased by increasing power consumption 2010-2012. But net profit is decreased. In addition, the eco-efficiency of all the recycling processes is decreased and analysis result of the eco-efficiency trends is located on the Fully non Eco-efficiency (--) level. Therefore, all the recycling processes are necessary improvement for power consumption reducing and net profit increasing to further the environmental and economically sustainable direction.