화력 발전용 보일러 덕트-홴 시스템의 진동현상에 대한 연구 : 입구측 와류에 의한 과대진동 사례 (A Study on the Vibration Phenomena of the Duct-fan Systems in Fossil Fueled Boilers : Inlet Vortex Induced Excessive Vibration)

  • 김철홍;주영호
    • 한국소음진동공학회논문집
    • /
    • 제13권3호
    • /
    • pp.194-201
    • /
    • 2003
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in a fan-duct system of fossil fueled boilers. We measured static pressure variation (pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this Paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

Inlet Cone Vortex에 의한 500 MW급 발전용 보일러 홴-덕트 시스템의 과대진동 (Excessive Vibration of the Fan-duct Systems in 500 MW Power Plant Boilers Due to Inlet Cone Vortex)

  • 김철홍;주영호;변형현
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.116-121
    • /
    • 2000
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in the fan-duct systems of fossil fueled boilers. We measured static pressure variation(pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure Pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

  • PDF

화력 발전용 보일러 Duct/Fan 시스템의 진동현상에 대한 연구 : Inlet Vortex에 의한 과대진동 사례 (A Study on the Vibration Phenomena of the Duct-fan Systems in Fossil Fueled Boilers: Inlet Vortex Induced Excessive Vibration)

  • 김철홍;주영호;변형현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.82-87
    • /
    • 2000
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in the fan-duct systems of fossil fueled boilers. We measured static pressure variation(pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

  • PDF

미소블록에 의한 교차 회전유동과 미소유로에 의한 박층유동을 이용한 정적 혼돈 미소유체 혼합기에 관한 연구 (Static Chaos Microfluid Mixers Using Alternating Whirls and Laminations)

  • 장성환;조영호
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1549-1556
    • /
    • 2004
  • We have deigned, fabricated and compared four different types of static chaos microfluid mixers, including the mixers using straight channel flow, microblock-induced alternating whirl flow, microchannel-induced lamination flow, and combined alternating whirl-lamination flow. Among them, the alternating whirl-lamination (AWL-type) mixer, composed of 3-D rotationally arranged microblocks and dividing microchannels fabricated by conventional planar lithography process, is effective to reduce the mixing length over wide flow rate ranges. We characterize the performance of the fabricated mixers, through the flow visualization technique using phenolphthalein solution. We verify that the AWL-type microfluid mixer shows the shortest fluid mixing length of 2.8mm∼5.8mm for the flow rate range of Re=0.26∼26 with the pressure drop lower than 5kPa. Compared to the previous mixers, requiring the mixing lengths of 7∼17mm, the AWL-type microfluid mixer results in the 60% reduction of the mixing lengths. Due to the reduced mixing lengths within reasonable pressure drop ranges, the present micromixers have potentials for use in the miniaturized Micro-Total-Analysis-Systems($\mu$TAS).

Development and validation of a numerical model for steel roof cladding subject to static uplift loads

  • Lovisa, Amy C.;Wang, Vincent Z.;Henderson, David J.;Ginger, John D.
    • Wind and Structures
    • /
    • 제17권5호
    • /
    • pp.495-513
    • /
    • 2013
  • Thin, high-strength steel roof cladding is widely used in residential and industrial low-rise buildings and is susceptible to failure during severe wind storms such as cyclones. Current cladding design is heavily reliant on experimental testing for the determination of roof cladding performance. Further study is necessary to evolve current design standards, and numerical modelling of roof cladding can provide an efficient and cost effective means of studying the response of cladding in great detail. This paper details the development of a numerical model that can simulate the static response of corrugated roof cladding. Finite element analysis (FEA) was utilised to determine the response of corrugated cladding subject to a static wind pressure, which included the anisotropic material properties and strain-hardening characteristics of the thin steel roof cladding. The model was then validated by comparing the numerical data with corresponding experimental test results. Based on this comparison, the model was found to successfully predict the fastener reaction, deflection and the characteristics in deformed shape of the cladding. The validated numerical model was then used to predict the response of the cladding subject to a design cyclone pressure trace, excluding fatigue effects, to demonstrate the potential of the model to investigate more complicated loading circumstances.

Immediate Effect of Eye Movement on Static Balance according to Age in Elderly Individuals

  • Seo, Seung-Hee;Bae, Hwi-Bin;Cho, Yea-Jin;Bae, Young-Sook
    • The Journal of Korean Physical Therapy
    • /
    • 제28권5호
    • /
    • pp.274-278
    • /
    • 2016
  • Purpose: This study investigated changes in static balance during eye movement while in an upright standing position and compared static balance in elderly individuals according to age. Methods: A total of 154 elderly persons (male 23, female 136) were enrolled in the study. Participants followed an eye movement program that consisted of randomly occurring pursuit eye movement and saccadic eye movement. Participants were asked to remain in the double-leg standing position for 2 minutes 30 second while fixating their eyes on a specific target, after which they were instructed to perform eye movements for 2 minutes and 30 seconds. Static balance was measured in terms of the area, length, and average speed (cm/s) of the center of pressure (COP) displacement before and after eye movement intervention with the eyes open. Results: The area, length, and velocity of COP displacement improved significantly (p< 0.01) after intervention. No significant differences among age groups were observed. Conclusion: The results indicated that eye movement was an effective intervention for improving static balance in elderly persons.

The Circadian Effects on Postural Stability in Young Adults

  • Son, Sung Min
    • The Journal of Korean Physical Therapy
    • /
    • 제29권3호
    • /
    • pp.142-144
    • /
    • 2017
  • Purpose: Few studies have addressed the effect of diurnal circadian rhythms on postural stability, and thus the aim of the present study was to examine circadian effects on static and dynamic postural stability in young adults. Methods: Twenty-four subjects (9 men, 11 women: age=$22.20{\pm}1.77$, height=$167.20{\pm}10.47$, weight=$59.85{\pm}10.66$) from a university community volunteered for this study. Static and dynamic balance testing, which recorded using a Good Balance system (Good Balance, Metitur Ltd, Finland) was conducted at 9:00, 13:00, and 17:00 hours on two consecutive days, and the sequencing of static and dynamic balance tests were randomized. Results were analyzed using the non-parametric one-way repeated Friedman test in SPSS version 18.0 (SPSS Inc., Chicago, IL, USA), and variable found to be significant were subjected to Wilcoxon post hoc testing. Results: Static and dynamic balance showed significant difference at the three times assessments (test at 9:00, 13:00, and 17:00) during circadian. In the post hoc test of static (anteroposterior distance, mediolateral distance and COP (center of pressure) velocity) and dynamic balance (performance time), 13:00 was the longer and faster than 9:00. Conclusion: These results indicated that control of postural balance is influenced by diurnal circadian rhythms, and confirm that control of postural balance is more effective and better performance in the 09:00 hours than 13:00 hours or 17:00 hours.

디퓨저 베인각의 변화에 따른 압축기 성능 특성 (Compressor Performance with Variation of Diffuser Vane Angle)

  • 신유환;김광호;배명형;김진형
    • 한국유체기계학회 논문집
    • /
    • 제3권2호
    • /
    • pp.36-43
    • /
    • 2000
  • This study presents the centrifugal compressor performance for three different vane stagger angles and wall pressure distribution within vaned diffuser channels, and is also discussed about the stability with respect to the compressor components. As the vane stagger angle decreases, the flow rate for the stall onset decreases, and higher pressure can be obtained at the low flow rate region, however, the effective operation range of the compressor decreases because of the blockage effect of the diffuser vane. Low pressure pocket within the vaned diffuser channel moves from the pressure side of leading edge to the suction side as the flow rate decreases. The compressor system stability mainly depends on that of the diffuser.

  • PDF

콘크리트 중력댐의 균열거동에 관한 연구 (A Study on the Crack Behaviour of the Concrete Gravity Dam)

  • 장희석;손병락;김희성
    • 한국전산구조공학회논문집
    • /
    • 제12권3호
    • /
    • pp.353-362
    • /
    • 1999
  • 본 연구에서는 콘크리트 중력식 댐의 임계균열길이가 계산되었으며 또한 복합균열의 균열선단에서 유효응력 확대계수의 변화량이 조사되었다. 작용하중으로는 댐 상부면에 작용하는 정수압과 댐의 균열면에 작용하는 수압 및 자중으로 구성된 정하중, 그리고 댐 주위에서 발파작업이 수행되는 경우에 고려될 수 있는 발파진동 및 동수압으로 구성된 동하중이 사용되었다. 균열이 발생한 위치와 방향 및 발파진동의 크기에 따라 임계균열길이가 계산되었으며, 또한 복합균열의 형태 및 균열선단 간의 이격거리에 따른 유효응력확대계수의 변화량이 검토되었다.

  • PDF

탄력밴드를 이용한 등척성 엉덩관절 벌림 교각운동이 전방머리자세 환자의 족저압에 미치는 영향 (The Effect Of Isometric Hip Abduction Bridge Exercise Using Elastic Band on Foot Pressure in Patients with Forward Head Posture)

  • 유재호;이상빈
    • 대한정형도수물리치료학회지
    • /
    • 제28권3호
    • /
    • pp.41-49
    • /
    • 2022
  • Background: In patients with forward head posture (FHP), the head is positioned forward, causing increased tension in the muscles and structures of the head, neck, and shoulders. This can result in joint dysfunction that may lead to abnormal afferent information. The purpose of this study was to investigate the effect on foot pressure through the isometric hip abduction (IHA) bridge exercise using elastic bands in patients with FHP. Methods: Twenty patients with FHP were randomly assigned to a study group that applied joint mobilization, soft tissue mobilization, a deep neck flexor strengthening exercise, and the IHA bridge exercise using an elastic band. A control group was also constituted, and members were given joint mobilization, soft tissue mobilization therapies, and the deep neck flexor strengthening exercise. Ten patients were assigned to each group. The static foot pressure and dynamic foot pressure of each patient were measured before and after the intervention, and the interventions for each group were applied twice a week for 4 weeks. Results: Both the study group and the control group showed significant differences in static and dynamic foot pressure before and after the interventions (p<.05). There were no significant differences in foot pressure between the study and control groups. Conclusion: : The results of this study revealed that there were no significant differences between the group doing the IHA bridge exercise using the elastic band and the control group. However, the intervention methods applied to both the groups were effective in improving the body center control of FHP patients.