• Title/Summary/Keyword: effective length

Search Result 3,111, Processing Time 0.027 seconds

Compensation for Distorted WDM Signals Through Dispersion Managed Optical Transmission Links with Ununiform Distribution of SMF Length and RDPS of Optical Fiber Spans (중계 구간의 SMF 길이와 RDPS 분포가 일정하지 않은 분산 제어 광전송 링크를 통한 왜곡된 WDM 신호의 보상)

  • Lee, Seong-Real
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.5
    • /
    • pp.801-809
    • /
    • 2012
  • Dispersion management (DM) is the typical technique compensating for the distorted signals due to interaction of group velocity dispersion (GVD) and optical nonlinear effects for transmitting wavelength division multiplexed (WDM) channel with the excellent performance. Optimal net residual dispersion (NRD) and effective launching power range of optical transmission links with random distribution and artificial distribution of single mode fiber (SMF) length and residual dispersion per span (RDPS) required to flexibly design of optical links in DM. It is confirmed that optimal net residual dispersion (NRD) are +10 ps/nm and -10 ps/nm controlled by precompensation and postcompensation, respectively, in both of the considered distribution patterns of SMF length and RDPS. And, in optimal NRD, system performance in optical links with the descending distribution of SMF length and the ascending distribution of RDPS among the artificial distribution patterns are more improved, consequently, effective launching power range is expanded by almost 2 dB than those in optical links with the uniform distribution.

Dependence of Ozone Generation in a Micro Dielectric Barrier Discharge on Dielectric Material and Micro Gap Length

  • Sakoda, Tatsuya;Sung, Youl-Moon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.5
    • /
    • pp.201-206
    • /
    • 2004
  • In order to investigate the optimum conditions for the effective ozone formation in a dielectric barrier discharge, measurements of ozone concentration were carried out for various conditions such as the gap length, the dielectric material and the operating gas. It was found that the optimum discharge conditions differed exceedingly in the types of operating gases and dielectric materials. In dry air, dielectric material with low dielectric constant and thermal conductivity, which might contribute to the restriction of the gas temperature rise in the discharge region, proved effective in obtaining both high ozone yield and concentration. The optimum gap length was considered to be in the range of 600-800 mm. In oxygen, using a quartz glass disk as a dielectric material, the required condition to obtain the high ozone yield and concentration was expanded.

Effects of San-Yin-Jiao(SP6) Acupressure on Labor Pain, Delivery Time in Women during Labor (삼음교(SP6)지압이 산부의 분만통증, 분만소요시간에 미치는 효과)

  • 이미경
    • Journal of Korean Academy of Nursing
    • /
    • v.33 no.6
    • /
    • pp.753-761
    • /
    • 2003
  • Purpose: The study was done to examine the effects of San- Yin-Jiao(SP6) acupressure treatment on subjective labor pain, length of delivery time in women during labor. Method: The study design was a randomized controlled clinical trial study using a double-blinded method. Data were collected using a structured questionnaire, a subjective labor pain scale and measurement of delivery time. The experimental group(n=29) was received SP6 acupressure and control group(n=29), SP6 touch for the duration of each uterine contraction, during 30 minutes after 3cm dilatation of cervical os. Result: The subjective labor pain scores was significantly different between the two groups(p=0.042). The total length of delivery time in the group which had the SP6 acupressure was shorter than SP6 touch group (p=0.036). Conclusion: These findings showed that SP6 acupressure was effective related to labor pain, length of time for delivery. SP6 acupressure during labor could be applied as an effective nursing treatment.

A Proposed method of the Strength Calculation of Pipe Support (파이프 서포트의 내력 산정 방안)

  • 이영욱;최순주
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.1
    • /
    • pp.59-64
    • /
    • 2001
  • Even though there is a guideline for the required strength of pipe support in inspection, it does not mean the nominal strength which can be used for the form work design. And, Concrete Specification defines that the pipe support should be designed according to the steel design guidelines but the design details are not provided, such as buckling length and the sectional modulus, etc. For the better prediction of strength of pipe support, the slenderness ratio of support which reflects the boundary condition should be considered. In this paper, the elastic buckling formula based on the slenderness is derived. The formula contains the strength reduction factor that consider the strength deduction caused by initial lateral deformation and is 0.65 consistently regardless of boundary conditions. And the coefficient of effective buckling length is calculated from the experiment.

  • PDF

A Study on the Optimal Span Length Selection of Conventional Railway Bridges considering Resonance Suppression (공진소멸 현상을 이용한 기존선 철도교량의 지간 최적화를 위한 연구)

  • Kim Sungil;Chung Wonseok;Choi Eunsoo
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.2
    • /
    • pp.137-144
    • /
    • 2005
  • The possibility of resonance exists always in railway bridges unlike highway bridges because railway bridges are loaded repeatedly by specific trains which has equidistant wheel loads. Resonance phenomenon of the bridge can be broken out when exciting frequencies by tram determined from the speed and effective beating internal coincides with natural frequencies of the bridge Excessive fluctuations of dynamic displacements and accelerations by resonance cause unpleasant passenger comfort and instability of railway structures. On the other hand, resonance suppression phenomenon that all the previous loads which pass through the bridge sum to zero can be occurred. In case we apply this resonance suppression properly, design of stable railway bridge from dynamics point of view can be made. In the present study, most dominant beating internal of conventional trams will be find. A(ter that. specific span length of the bridge which derives resonance suppression can be selected for railway bridges which accomplishes superior dynamic behavior.

The Energy Absorption Characteristics of Thin-walled Rectangular Tubes (박판 사각튜브의 에너지 흡수 특성)

  • 김천욱;한병기;원종진;임채홍
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.83-91
    • /
    • 1996
  • This paper investigates the energy absorption characteristics of thin-walled rectangular tubes. In the compact mode, the crushing process of a thin-walled tube is analyzed into 3 parts by the ratio of outward to inward fold length. The mean crush load and the half-wave folding length are determined by using minimum energy principle. The effective crush distance can be determined when half-wave folding length is known, and the number of folds is derived when crush distance is given. Thus when the crush distance is given, energy absorption capacity can be estimated with mean crush load and number of folds. And the theoretical value is proven experimentally.

  • PDF

The Threshold Voltage and the Effective Channel Length Modeling of Degraded PMOSFET due to Hot Electron (Hot electron에 의하여 노쇠화된 PMOSFET의 문턱전압과 유효 채널길이 모델링)

  • 홍성택;박종태
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.8
    • /
    • pp.72-79
    • /
    • 1994
  • In this paper semi empirical models are presented for the hot electron induced threshold voltage shift(${\Delta}V_{t}$) and effective channel shortening length (${\Delta}L_{H}$) in degraded PMOSFET. Trapped electron charges in gate oxide are calculated from the well known gate current model and ΔLS1HT is calculated by using trapped electron charges. (${\Delta}L_{H}$) is a function of gate stress voltage such as threshold voltage shift and degradation of drain current. From the correlation between (${\Delta}L_{H}$) has a logarithmic function of stress time. From the measured results, (${\Delta}V_{t}$) and (${\Delta}L_{H}$) are function of initial gate current and device channel length.

  • PDF

Storey-based stability analysis of multi-storey unbraced frames

  • Liu, Y.;Xu, L.
    • Structural Engineering and Mechanics
    • /
    • v.19 no.6
    • /
    • pp.679-705
    • /
    • 2005
  • This paper presents a practical method to evaluate the effective length factors for columns in multi-storey unbraced frames based on the concept of storey-based elastic buckling by means of decomposing a multi-storey frame into a series of single-storey partially-restrained (PR) frames. The lateral stiffness of the multi-storey unbraced frame is derived and expressed as the product of the lateral stiffness of each storey. Thus, the stability analysis for the multi-storey frame is conducted by investigating the lateral stability of each individual storey, which is facilitated through decomposing the multi-storey frame into a series of single-storey PR frames and applying the storey-based stability analysis proposed by the authors (Xu and Liu 2002) for each single-storey PR frame. Prior to introducing decomposition approaches, the end rotational stiffness of an axially load column is derived and rotational stiffness interaction between the upper and lower columns is investigated. Three decomposition approaches, characterized by means of distributing beam-to-column rotational-restraining stiffness between the upper and lower columns, are proposed. The procedure of calculating storey-based column effective length factors is presented. Numerical examples are then given to illustrate the effectiveness of the proposed procedure.

An Experimental Study on the Heat Transfer Characteristics of a High-temperature Sodium Heat Pipe Depending on the Thermal Transport Conditions (고온 나트륨 히트파이프에서 열이송 조건에 따른 열전달 특성에 대한 실험 연구)

  • Park, C.M.;Boo, J.H.;Kim, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2340-2345
    • /
    • 2008
  • Cylindrical stainless-steel/sodium heat pipe for a high-temperature application was manufactured and tested for transient and steady-state operations. Two layers of Stainless-steel screen mesh wick was inserted as a capillary structure. The outer diameter of the heat pipe was 12.7 mm and the total length was 250 mm. As thermal transport conditions, the effective transport length, the heat flux, the tilt angle and the operating temperature were varied. The heat was supplied by an electric furnace up to 1 kW and the cooling was performed by forced convection of air. The effective thermal conductivity and the thermal resistance were investigated as a function of heat flux, heat transport length, and vapor temperature. Typical range of the total thermal resistance was as low as $0.036^{\circ}C/W$ at $175.8\;kW/m^2$ of heat flux and $700^{\circ}C$ of operating temperature.

  • PDF

Numerical study on pressure drop with moving contact lines of dry slug flow in a hydrophobic minichannel (소수성 미니채널 내 움직이는 접촉선을 가진 액체슬러그의 압력 강하에 대한 수치해석)

  • Jeon, Jun Ho;Park, Su Chung;Yu, Dong In;Kim, Tae Hun;Lee, Yeon Won
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.3
    • /
    • pp.116-121
    • /
    • 2020
  • In this study, a single-phase analysis of droplet slug with different contact angles was performed based on the visualization of experimental results. Droplet slug - flowing between gases in a hydrophobic mini channel - moves with a triple contact line without a gas liquid film on the wall. The results show that the rotational flow inside the droplet occurred; this was compared and verified with the results of two-phase analysis. The pressure field shows pressure rise at the front and rear ends. The effective length - the section that satisfies the laminar flow condition - became shorter as the droplet velocity increased. The Choi's correlation for the effective length agrees with this analysis results with a slight difference. This difference is judged as the difference in the contact angle of the slug model.